User manual TOSHIBA RAS-3M23GACV-E SERVICE MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAS-3M23GACV-E. We hope that this TOSHIBA RAS-3M23GACV-E user guide will be useful to you.


TOSHIBA RAS-3M23GACV-E SERVICE MANUAL: Download the complete user guide (3853 Ko)

You may also download the following manuals related to this product:

   TOSHIBA RAS-3M23GACV-E (821 ko)
   TOSHIBA RAS-3M23GACV-E INSTALLATION MANUAL (1434 ko)
   TOSHIBA RAS-3M23GACV-E DATA BOOK (41 ko)

Manual abstract: user guide TOSHIBA RAS-3M23GACV-ESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] A05-014 SERVICE MANUAL SPLIT TYPE <Cooling OnlyType> Indoor Unit RAS-M10GKCVP-E RAS-M13GKCVP-E RAS-M16GKCVP-E Outdoor Unit RAS-3M23GACV-E R410A PRINTED IN JAPAN, Jan. , 2006 ToMo CONTENTS 1. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] An approved power supply cord and plug must be used. Anchor bolt Projection 15mm or less Fig. 10-3-4 NOTE : · Perform wiring work being sure the wire length is long enough. 5 mm dia. Wiring Connection How to connect the connecting cable 7 Mounting screw Ø4 × 25L Clip anchor (local parts) Fig. 10-3-5 CAUTION Failure to securely install the unit may result in personal injury and/or property damage if the unit falls. · In case of block, brick, concrete or similar type walls, drill 5 mm dia. · Insert clip anchors for the mounting screws. NOTE : · Install the installation plate using mounting screws between 4 to 6, being sure to secure all four corners. Wiring the connecting cable can be carried out without removing the front panel. Insert the connecting cable (or as according to local regulations/codes) into the pipe hole on the wall. Pull the connecting cable through the cable slot on the rear panel so that it protrudes about 15 cm out of the front. Insert the connecting cable fully into the terminal block and secure it tightly with screws. Attach the terminal cover, rear plate bushing and air inlet grille on the indoor unit. ­ 51 ­ CAUTION · Be sure to refer to the wiring system diagram labeled inside the front panel. · Check local electrical regulations for any specific wiring instructions or limitations. Terminal cover 10-3-5. Piping and Drain Hose Installation Piping and drain hose forming · Since condensation results in machine trouble, make sure to insulate both the connecting pipes separately. (Use polyethylene foam as insulating material. ) Rear right Cord clamp Left Terminal block Bottom right Right Earth wire Connecting cable Fig. Die-cutting front panel slit Cut out the slit on the left or right side of the front panel for the left or right connection and the slit on the bottom left or side of thefront panel for the bottom left or right connection with a pair of nippers. Changing drain hose For left connection, left-bottom connection and rear-left connection's piping, it is necessary to relocate the drain hose and drain cap. Fig. 10-3-7 How to remove the drain cap Clip drain cap with needle-nose pliers, and pull out. Connecting cable About 15 cm Fig. 10-3-11 How to remove the drain hose The drain hose is secured in place by a screw. Remove the screw securing the drain hose, then pull out the drain hose. 10 mm 50 mm Fig. 10-3-12 ­ 52 ­ Die-cutting Front panel slit Bottom left Drain hose Changing drain hose Rear left Piping preparation Screw Screw How to attach the drain cap 1. Insert hexagonal wrench (4 mm). In case of bottom right or bottom left piping · After making slits on the front panel with a knife or similar tool, cut them out with a pair of nippers or an equivalent tool. Slit 4 mm Fig. Bend the connecting pipes so that they are positioned within 43 mm above the wall surface. If the connecting pipes are positioned more than 43 mm above the wall surface, the indoor unit may be unstable. [. . . ] NOTE Remarks Cutting here Connector 100 Thermal sensor part 200 Cutting here 15 70 Thermal constringent tube Cutting here 100 15 70 Soldered part Dryer Winding the color tape 1) Store the joint part of the sensor and the connector in the electric parts box. 3) When replacing the sensor using the colored protective tube, wind the color tape matching the color of that tube. These are parts for servicing sensors. Please check that the accessories shown in the right table are packed. Parts name 1 2 3 4 5 6 Sensor Sensor Spring (A) Sensor Spring (B) Thermal constringent tube Color tape Terminal Q'ty 1 1 1 3 1 3 Remarks Length : 3m For spare For spare Including one spare 9 colors ­ 98 ­ <MCC-1438> ­ 99 ­ <MCC-818> ­ 100 ­ 13. Indoor Unit (1) 240 238 247 235 236 201 203 221, 222, 224 246 227 205 202 245 204 232 233 228 206 229 239 223 210 218, 219 207 215 211 216 213 225, 226 212 230 214 234 217 209 The parts in the following parts list are conformed to RoHS. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-3M23GACV-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-3M23GACV-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.