User manual TOSHIBA RAS-24UAH-E SERVICE MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAS-24UAH-E. We hope that this TOSHIBA RAS-24UAH-E user guide will be useful to you.


TOSHIBA RAS-24UAH-E SERVICE MANUAL: Download the complete user guide (10974 Ko)

Manual abstract: user guide TOSHIBA RAS-24UAH-ESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] SVM-01007 SERVICE MANUAL AIR-CONDITIONER SPLIT WALL TYPE RAS-24UKHP-E / RAS-24UAH-E RAS-24UKP-E / RAS-24UA-E RAS-24UKPX / RAS-24UAX RAS-24UKP-AR / RAS-24UA-AR RAS-24UKPX-T/RAS-24UAX-T RAS-18UKHP-E/RAS-18UAH-E RAS-18UKP-E/RAS-18UA-E RAS-18UKPX/RAS-18UAX RAS-18UKP-AR/RAS-18UA-AR RAS-18UKPX-T/RAS-18UAX-T 18 Class 24 Class TCTC Service Manual 24/18UKHP-E (EN) File No. SPECIFICATIONS 1-1 RAS-24UKHP-E/24UAH-E, RAS-24UKP-E/24UA-E RAS-24UKPX/24UAX, RAS-24UKP-AR/24UA-AR RAS-24UKPX-T/24UAX-T 1-2 RAS-18UKHP-E/18UAH-E, RAS-18UKP-E/18UA-E RAS-18UKPX/18UAX, RAS-18UKP-AR/18UA-AR RAS-18UKPX-T/18UAX-T 2. CONSTRUCTION VIEWS 2-1 Indoor Unit (RAS-24UKHP-E, 24UKP-E, 24UKPX, 24UKP-AR, 24UKPX-T) 2-2 Indoor Unit (RAS-18UKHP-E, 18UKP-E, 18UKPX, 18UKP-AR, 18UKPX-T) 2-3 Outdoor Unit (RAS-24UAH-E, 24UA-E, 24UAX, 24UA-AR, 24UAX-T) 2-4 Outdoor Unit (RAS-18UAH-E, 18UA-E, 18UAX, 18UA-AR, 18UAX-T) 3. WIRING DIAGRAM 3-1 RAS-24UKHP-E/RAS-24UAH-E 3-2 RAS-24UKP-E/RAS-24UA-E RAS-24UKPX/RAS-24UAX RAS-24UKP-AR/RAS-24UA-AR RAS-24UKPX-T/RAS-24UAX-T 3-3 RAS-18UKHP-E/RAS-18UAH-E 3-4 RAS-18UKP-E/RAS-18UA-E RAS-18UKPX/RAS-18UAX RAS-18UKP-AR/RAS-18UA-AR RAS-18UKPX-T/RAS-18UAX-T 4. [. . . ] · A place where the drain water does not raise any problem. 8-5-2. Cut the pipe with a pipe cutter. 90° Obliquity Roughness Warp Fig. · Projection margin in flaring : A (Unit : mm) A Die Pipe Fig. Of copper pipe A Rigid Imperial 6. 35 1. 0 to 1. 5 1. 0 to 1. 5 1. 0 to 1. 5 1. 5 to 2. 0 2. 0 to 2. 5 2. 0 to 2. 5 CAUTION 1. Install the outdoor unit without anything blocking the air discharging. When the outdoor unit is installed in a place exposed always to a strong wind like a coast or on a high story of a building, secure the normal fan operation using a duct or a wind shield. Specially in windy area, install the unit to prevent the admission of wind. · A place where high-frequency waves are likely to be generated as from audio equipment, welders, and medical equipment. 12. 7 15. 88 <Tightening Connection> Align the centers of the connecting pipes and tighten the flare nut as far as possible with your fingers. Then tighten the nut with a spanner and torque wrench as shown in the figure. CAUTION · Do not apply excess torque. Otherwise, the nut may crack depending on the conditions. Strong wind Fig. 8-5-1 ­ 43 ­ TCTC Service Manual 24/18UKHP-E (EN) File No. Of copper pipe Tightening torque Ø6. 35 mm Ø12. 7 mm Ø15. 88 mm 16 to 18 (1. 6 to 1. 8 kgf·m) 50 to 62 (5. 0 to 6. 2 kgf·m) 65 to 80 (6. 5 to 8. 0 kgf·m) After the piping has been connected to the indoor unit, you can perform the air purge together at once. AIR PURGE Evacuate the air in the connecting pipes and in the indoor unit using vacuum pump. <Use a vacuum pump> Be sure to use a vacuum pump with counter-flow prevention function so that inside oil of the pump does not flow backward into pipes of the air conditioner when the pump stops. Connect the charge hose from the manifold valve to the service port of the gas side packed valve. Perform evacuating for about 15 minutes if the piping length is 20 meters. (15 minutes for 20 meters) (assuming a pump capacity of 27 liters per minute. ) Then confirm that the compound pressure gauge reading is ­101 kPa (­76 cmHg). Open fully the valve stem of the packed valves (both side of Gas and Liquid). Securely tighten the caps on the packed valves. Compound pressure gauge -101kPa (-76cmHg) Manifold valve Pressure gauge · Tightening torque of flare pipe connections Flare at indoor unit side Flare at outdoor unit side Fig. 8-5-4 Half union Flare nut Externally threaded side Use a wrench to secure. Internally threaded side Use a torque wrench to tighten. Fig. 8-5-5 CAUTION · KEEP IMPORTANT 4 POINTS FOR PIPING WORK (1) Take away dust and moisture (Inside of the connecting pipes. ) (2) Tight connection (between pipes and unit) (3) Evacuate the air in the connecting pipes using VACUUM PUMP. (4) Check gas leak (connected points) Handle Lo Charge hose Handle Hi (Keep full closed) Charge hose Connecting pipe Vacuum pump adapter for counter-flow prevention Vacuum pump Packed valve at gas side Service port (Valve core (Setting pin)) Packed valve at liquid side Fig. 8-5-6 ­ 44 ­ TCTC Service Manual 24/18UKHP-E (EN) File No. [. . . ] 222 223 224 225 226 227 228 239 230 231 232 233 234 235 236 237 238 239 240 241 242 Part No. Description 43T00048 Front Panel, ASSY 43T00049 Grille ASSY 43T00050 Grille ASSY 43T80014 Air Filter (L) 43T80013 Air Filter (R) 43T80003 Filter, Frame 43T01004 Mark 43T03010 Body, Right 43T03011 Body, Left 43T03012 Hide, Claw 43T09036 Grille, Horizontal 43T70301 Hose ASSY, Drain 43T21029 Motor, Stepping 43T44311 Refrigeration Cycle Assembly 43T47311 Pipe, Deliver 43T47016 Pipe, Suction 43T49010 Pipe, Shield 43T19003 Holder, Sensor 43T49009 Spring 43T49036 Plate, EVA-Seal 43T49039 Holder, Plate EVA-Seal 43T49038 Plate, EVA-Seal 43T49037 Holder, Plate EVA-Seal 43T79007 Guide Drain 43T39016 Fix For Motor 43T60075 Fan Motor Cord 43T21028 Motor, Fan 43T20014 Fan, Cross Flow 43T22008 Bearing 43T39015 Base, Bearing 43T03013 Back Body ASSY 43T03301 Back Body ASSY 43T07022 Holder, Pipe 43T82007 Plate, Installation 43T85065 Owner's Manual 43T85064 Owner's Manual 43T85317 Owner's Manual 43T85318 Owner's Manual 43T69070 Remote Control, Wireless 43T69071 Remote Control, Wireless 43T83003 Holder, Remote Control 43T62029 Cover, Terminal ­ 73 ­ TCTC Service Manual 24/18UKHP-E (EN) File No. 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 Part No. Description Location No. 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 42 Part No. Description 43T00024 Panel, Air Outlet 43T00025 Panel, Front 43T00026 Panel, Side 43T42002 Base Assembly 43T19012 Guard, Fin 43T19011 Guard, Fan 43T91001 Plate, Roof 43T42005 Plate, Valve, Packed 43T15001 Handle 43T43317 Condenser Assembly 43T46014 Valve, Packed, 15. 88 43T46016 Valve, Packed, 6. 35 43T47310 Bonnet, 15. 88 Dia. 43T60035 Terminal Block, 4P 43T60036 Terminal Block, 3P, 30A 43T60037 Filter, Clamp 43T41313 Compressor, PH310X3-4MM 43T62014 Protector, Cord 43T62015 Protector, Cord 43T49011 Base, Spring A 43T49019 Spring, Buffer 43T49012 Base, Spring B 43T21306 Motor, Fan, AC220 ­ 240V 50Hz 43T20010 Fan, Propeller, 490 43T96001 Bushing 43T96004 Bushing, Cord 43T62013 Cover, E-Parts 43T52301 Switch, Magnet, CLK-35J 43T55016 Capacitor, 60MFD, 420V 43T55014 Capacitor, 3. 5MFD, 450V 43T96003 Clip, Cable 43T46482 Valve, 4way 43T43319 Coil, V-4way AC220 ­ 240V, VHV 43T69059 Sensor 43T69060 Sensor, TD 43T79004 Nipple, Drain 43T58301 Transformer, TT-05 43T69057 P. C. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-24UAH-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-24UAH-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.