User manual TOSHIBA RAS-13YKV-E SERVICE MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAS-13YKV-E. We hope that this TOSHIBA RAS-13YKV-E user guide will be useful to you.


TOSHIBA RAS-13YKV-E SERVICE MANUAL: Download the complete user guide (3186 Ko)

Manual abstract: user guide TOSHIBA RAS-13YKV-ESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] A00-T004 SUPPLEMENT SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-10YKV-E / RAS-10YAV-E RA-88YKV-E / RAS-13YAV-E R410A PRINTED IN JAPAN, Aug. , 2000 ToMo CONTENTS 1. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2. REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3. CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 4. [. . . ] Insert the connecting cable (according to local cords) into pipe hole on the wall. Take out the connecting cable through the cable slot on the rear panel so that it is exploded by about 15 cm long in the front side. Insert the connecting cable fully into the terminal block and secure it by screw tightly. Fix the wiring cover, rear plate bushing and front cabinet on the indoor unit. 9-2-5. Piping and Drain Hose Installation In case of rightward piping · After scribing slits of the front cabinet and the rear panel by a knife or a marking-off pin, cut them by a pair of nippers or the like. Pass the pipe through the hole in the wall, and hook the indoor unit on the installation plate at the upper hooks. Swing the indoor unit to right and left to confirm that it is firmly hooked up on the installation plate. While pressing the indoor unit onto the wall, hook it at the lower part on the installation plate. Pull the indoor unit toward you to confirm that it is firmly hooked up on the installation plate. 1 Slit (rear panel) In case of downward piping · After scribing the slit of the front cabinet and slit in the lower part of the rear panel by a knife or a marking-off pin, cut them by a pair of nippers or the like. 9-2-13 Hook here 1 Installation plate Slit (front cabinet) 2 Slit (rear panel) Hook Press (unhook) Fig. 9-2-16 CAUTION · Be sure to refer to the wiring system diagram labeled inside the front panel. · Check local electrical cords and also any specific wiring instructions or limitation. Terminal block Connecting cable Cord Terminal clamp cover Screw Screw Screw Connecting cable Earth line Left-hand connection with piping Bend the connecting pipe so that it is laid within 43 mm above the wall surface. If the connecting pipe is laid exceeding 43 mm above the wall surface, the indoor unit may unstably be set on the wall. When bending the connecting pipe, make sure to use spring bender so as not to crush the pipe. To connect pipe after installation of unit (figure) (To the forefront of flare) 196mm 96mm Liquid side Gas side · For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing its bottom up at the specified parts. Push Push Fig. NOTE · Hole should be made at a slight downward slant on the outdoor side. Do not rise the drain hose. Do not form the drain hose into the waved shape. Outward form of indoor unit 43mm ­ 38 ­ 9-2-4. 9-2-8 abo ut 1 5cm R 30mm (Use polisin (polyethylene core) or the like for bending pipe. ) 50 mm or more ° 80 Stripping length of connecting cable 123 10mm 10mm Use the handle of screwdriver, etc. 123 50mm 40mm (1) (2) (3) (1) (2) Vertical air flow louver NOTE Earth line NOTE Connect the earth line to the metallic part ( mark) located at the side of 3P terminal. Fig. 9-2-14 NOTE If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall. After passing the connecting pipe through the pipe hole, connect the connecting pipe to the auxiliary pipes and wrap the facing tape around them. Do not put the drain hose end into water. Do not put the drain hose end in the drainage ditch. Fig. 9-2-6 How to open the screw cap · Place your finger on the lower part and push to open the screw cap. Use stranded wire only. WIRE TYPE : more than H05 RN-F CAUTION · Bind the auxiliary pipes (two) and connecting cable with facing tape Indoor unit tightly. [. . . ] 43T69062 Description Terminal Block, 3P , AC 300V, 20A 43T69004 Sensor, Heat Exchanger 10k, 25°C 43T69005 Sensor, Thermostat 10k, 25°C 43T69031 P Board, Assembly, . C. MCC-772 (13YKV-E) 43T61001 Base, E-Parts, ABS, Black UL94-5V 43T62006 Base, Shield SGCC-Z08-LUB ­ 69 ­ Indoor Unit (2) RAS-10YKV-E, RAS-13YKV-E 233 230 222 221 215 211 216 217 226 229 244 232 228 231 201 202 214 210 206 245 207 243 220 224 218 219 225 227 236 241 237 212 209 208 246 213 239 203 204 242 238 Location No. 201 202 203 204 206 207 208 208 209 210 211 212 213 214 215 216 217 218 219 220 221 Part No. 43T00043 43T00044 43T80001 43T80002 43T07021 43T07020 43T08106 43T08107 43T19004 43T09035 43T09004 43T70001 43T21003 43T07001 43T44024 43T47006 43T47005 43T49007 43T19003 43T49003 43T49028 Description Front Panel Assembly Grille, Suction Air Filter (L) Air Filter (R) Screw Cap (L) Screw Cap (R) LED Panel (10YKV-E) LED Panel (13YKV-E) Accepted Signal Filter Horizontal Louver Assembly for Service Louver Assembly Drain Hose Assembly Motor, Stepping Bushing Refrigerant Cycle Assembly Pipe, Delivery Pipe, Suction Pipe, Shield Holder, Sensor Spring Plate, EVA-SEAL Location No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-13YKV-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-13YKV-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.