User manual TOSHIBA RAS-13UKV-E SERVICE MANUAL
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAS-13UKV-E. We hope that this TOSHIBA RAS-13UKV-E user guide will be useful to you.
You may also download the following manuals related to this product:
TOSHIBA RAS-13UKV-E PSD (46 ko)
Manual abstract: user guide TOSHIBA RAS-13UKV-ESERVICE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] A02-001
SPLIT TYPE
RAS-13UKV-E RAS-13UAV-E
PRINTED IN JAPAN, Mar. , 2002 ToMo
CONTENTS
1. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Also it must be avoided to put anything on the top of the indoor unit.
Mounting the Installation Plate
For installation of the indoor unit, use the paper pattern on the back.
Anchor bolt holes
Hook
62 82. 5
2m or more from floor
170 85
Pipe hole
Hook
Thread
Weight
Hook
Pipe hole 7 Mounting screw
1 Installation plate
Indoor unit
CAUTION
· Direct sunlight to the indoor unit wireless receiver should be avoided. · The microprocessor in the indoor unit should not be too close to r-f noise sources. 9-2-3
When the installation plate is directly mounted on the wall
1. Securely fit the installation plate onto the wall by screwing it in the upper and lower parts to hook up the indoor unit. To mount the installation plate on a concrete wall with anchor bolts, utilize the anchor bolt holes as illustrated in the above figure. Install the installation plate horizontally in the wall.
Remote controller
· A place where there are no obstacles such as a curtain that may block the signal from the indoor unit. · Do not install the remote controller in a place exposed to direct sunlight or close to a heating source, such as a stove. · Keep the remote controller at least 1 m apart from the nearest TV set or stereo equipment. (This is necessary to prevent image disturbances or noise interference. ) · The location of the remote controller should be determined as shown below.
Indoor unit
(Side view) (Top view)
CAUTION
When installing the installation plate with mounting screw, do not use the anchor bolt hole. Otherwise the unit may fall down and result in personal injury and property damage.
5m
5m
45°
7m
Indoor unit
Anchor bolt
° 45
* 7m
Projection 15mm or less
75
°
Reception Remote controller range
Reception range
Remote controller
*
: Axial distance
Fig. Cutting a Hole and Mounting Installation Plate
Cutting a Hole
When install the refrigerant pipes from the rear.
Clip anchor (local parts)
7 Mounting screw Ø4 x 25
Fig. 9-2-5
Pipe hole
Ø6 5m m
CAUTION
Failure to firmly install the unit may result in personal injury and property damage if the unit falls. · In case of block, brick, concrete or similar type walls, make 5 mm dia. NOTE : · Install the installation plate using 4 to 6 pieces of mounting screw securing four corners with screws.
The center of the pipe hole is above the arrow.
100mm
Fig. After determining the pipe hole position on the ), drill the pipe hole (Ø65 mm) at mounting plate ( a slight downward slant to the outdoor side. NOTE : · When drilling the wall that contains a metal lath, wire lath or metal plate, be sure to use a pipe hole brim ring sold separately.
38
9-2-3. The supply voltage must be the same as the rated voltage of the air conditioner. NOTE : · Wire type : More than H07RN-F or 245IEC66 (1. 0mm² or more)
Connecting cable
abo
Terminal cover Cord clamp Screw
Terminal block
ut 1
5 cm
Earth line
CAUTION
· This appliance can be connected to the mains in either of the following two ways. (1) Connection to fixed wiring : A switch or circuit breaker which disconnects all poles and has a contact separation of at least 3 mm must be incorporate in the fixed wiring. (2) Connection with power supply plug : Attach power supply plug with power cord and plug it into wall outlet. NOTE : · Perform wiring works so as to allow a generous wiring capacity.
Screw
Screw
Connecting cable
Fig. 9-2-6
80mm 10mm 10mm
3 2 1
Earth line
70mm
10mm 50mm
NOTE : WIRE TYPE : more than H07 RN-F or 245 IEC 66. [. . . ] 3) Remove the hooking claws by pushing minus screwdriver according to the arrow mark in the right figure, and remove the fan guard.
Minus screwdriver Hooking claw
2. Attachment 1) Insert claw of the fan guard in the hole of the front cabinet. Push the hooking claws (10 positions) by hands and fix the claws.
All the attaching works have completed. Check that all the hooking claws are fixed to the specified positions.
71
No.
11
Part name Replacement of temperature sensor for servicing only Common service parts of sensor TO, TS, TE, TD
Procedure 1) Cut the sensor 100 mm longer than old one. [. . . ]