User manual TOSHIBA RAS-13UKH SERVICE MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAS-13UKH. We hope that this TOSHIBA RAS-13UKH user guide will be useful to you.


TOSHIBA RAS-13UKH SERVICE MANUAL: Download the complete user guide (1538 Ko)

Manual abstract: user guide TOSHIBA RAS-13UKHSERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] SPECIFICATIONS MODEL ITEM Capacity 220V kW Phase Power source Power consumption Power factor Running current Indoor Outdoor V Hz kW % A A A lit/h dB kg mm mm 47 49 0. 78 Capillary tube 9. 52 Flare connection 6. 35 Flare connection m m RAS-10SKHP-ES Height Dimensions Net weight Evaporator type Indoor fan type High fan Air volume Medium fan Low fan Fan motor output Air filter OUTDOOR UNIT Height Dimensions Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Safety device Louver type Usable outdoor temperature range °C 15 ~ 43 Model Output W m3/h W 2030 2150 30 PA108X1C-4FZDN 750 Fuse, Overload relay Automatic louver -10 ~ 24 15 ~ 43 Width Depth mm mm mm kg 31 Finned tube Propeller fan 2030 2150 1740 20 1850 m3/h m3/h m3/h W 540 460 390 Width Depth mm mm mm kg 250 740 195 8 Finned tube Cross flow fan 560 500 400 20 Honeycomb woven filter with PP frame RAS-13UKH 550 780 290 30 RAS-10SA-ES 540 460 390 10*1 5 RAS-10SKP-ES 47 R410A 0. 72 3. 71 3. 50 3. 55 18 1. 2 39/37/35/33/31 49 46 47 0. 83 98 0. 85 97 0. 79 97 0. 15 3. 40 3. 71 3. 50 2. 73 RAS-10SKHP-ES / RAS-13UKH Cooling 240V 2. 73 220V 2. 92 1 220 - 240 50 0. 82 96 0. 83 98 0. 85 97 Heating 240V 2. 96 RAS-10SKP-ES / RAS-10SA-ES Cooling 220V 2. 73 240V 2. 73 Starting current Moisture removal Noise Refrigerant Outdoor (220-240V) Name of refrigerant Rated amount Gas side size Connection type Liquid side size Interconnection Connection type pipe Maximum length (One way) Maximum height difference INDOOR UNIT Indoor (H/M+/M/L+/L) dB Refrigerant control -3- FILE NO. SVM-09029 Note : 1 · Capacity is based on the following temperature conditions. Condition (DB) (WB) (DB) (WB) JIS C9612 Cooling 27°C 19°C 35°C 24°C Heating 20°C 15°C 7°C 6°C Temperature Indoor unit inlet air temperature Outdoor unit inlet air temperature Note : 2 *1 No need to change extra refigerant. -4- FILE NO. Indoor Unit Front panel Air inlet Air filter 739 Heat exchanger 195 252 52 60 8 Knock out system Air outlet 58 8 Knock out system 50 50 55 60 104. 39 499 60 55 133. 41 56 Wireless remote controller 63 26 Remote controller holder Drain hose (0. 5m) Hanger 290 Connecting pipe (0. 37m) (Flare 6. 35) Connecting pipe (0. 37m) (Flare 9. 52) 606 235 215 45. 9 235 215 Hanger For stud bold ( 8~ 10) For stud bold ( 6) 26. 6 45. 9 90 135 Hanger 145 145 Hanger 135 38 90 Installation plate outline Center line ­5­ 40 164. 1 250 125 157 19 FILE NO. [. . . ] Securely fit the installation plate onto the wall by screwing it in the upper and lower parts to hook up the indoor unit. To mount the installation plate on a concrete wall with anchor bolts, utilize the anchor bolt holes as illustrated in the above figure. The supply voltage must be the same as the rated voltage of the air conditioner. Prepare the power source for exclusive use with the air conditioner. CAUTION · This appliance can be connected to the mains in either of the following two ways. (1) Connection to fixed wiring: A switch or circuit breaker which disconnects all poles and has a contact separation of at least 3 mm must be incorporate in the fixed wiring. (2) Connection with power supply plug: Attach power supply plug with power cord and plug it into wall outlet. NOTE · Ensure all wiring is used within its electrical rating. Model 10 Class CAUTION When installing the installation plate with a mounting screw, do not use the anchor bolt hole. Otherwise the unit may fall down and result in personal injury and property damage. Installation plate <Keep horizontal direction> Anchor bolt 5 mm dia. hole Projection 15 mm or less 7 Mounting screw 4 x 25s s Power source Maximum running current Plug socket & fuse rating 50Hz, 220 - 240 V Single phase 7. 5A 16A 1 mm2 or more Clip anchor (local parts) Fig. 8-4-4 Power cord CAUTION Failure to firmly install the unit may result in personal injury and property damage if the unit falls. · In case of block, brick, concrete or similar type walls, make 5 mm dia. Swing the indoor unit to right and left to confirm that connecting pipe, make sure to use a spring bender so it is firmly hooked up on the installation plate. While pressing the indoor unit onto the wall, hook it at the lower part on the installation plate. indoor unit toward you to confirm that it is firmly To connect the pipe after installation of the unit (figure) hooked up on the installation plate. (To the forefront of flare) 210 mm 165 mm Hook here 1 Liquid side Gas side 2 1 Installation plate Hook Outward form of indoor unit 43 mm Press (unhook) R 30 mm (Use polisin (polyethylene) core or the like for bending pipe. ) Fig. 8-4-15 · For detaching the indoor unit from the installation plate, pull the indoor unit toward you while pushing its bottom up at the specified parts. 80 Use the handle of screwdriver, etc. Fig. 8-4-14 NOTE If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall. After passing the connecting pipe through the pipe hole, connect the connecting pipe to the auxiliary pipes and wrap the facing tape around them. Push Push CAUTION · Bind the auxiliary pipes (two) and connecting cable with facing tape tightly. In case of leftward piping and rear-leftward piping, bind the auxiliary pipes (two) only with facing tape. Indoor unit Auxiliary pipes Connecting cable Fig. 8-4-16 Installation plate · Carefully arrange pipes so that any pipe does not stick out of the rear plate of the indoor unit. · Carefully connect the auxiliary pipes and connecting pipes to each other and cut off the insulating tape wound on the connecting pipe to avoid double-taping at the joint, moreover, seal the joint with the vinyl tape, etc. · Since dewing results in a machine trouble, make sure to insulate both the connecting pipes. (Use polyethylene foam as insulating material. ) · When bending a pipe, carefully do it, not to crush it. [. . . ] 2) Pull the air inlet grille toward you to open it and remove the air inlet grille. 3) First open the horizontal louver, and then remove the front panel from the back body by pulling it toward you. How to mount the front panel Push the front panel back in and make sure all hooks are locked. 2 Electrical part Remarks 2 2 2 2 2-Screws 3 How to remove the electrical part. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-13UKH




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-13UKH will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.