User manual TOSHIBA RAS-11LKX SERVICE MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAS-11LKX. We hope that this TOSHIBA RAS-11LKX user guide will be useful to you.


TOSHIBA RAS-11LKX SERVICE MANUAL: Download the complete user guide (4716 Ko)

Manual abstract: user guide TOSHIBA RAS-11LKXSERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] CONSTRUCTION VIEWS Indoor Unit Front panel Air inlet Air filter Heat exchanger 790 218 275 60 Air outlet 48 6 Knock out system Knock out system 64 53 120 590 Hanger 80 Drain hose (0. 54m) Hanger 320 Connecting pipe (0. 43m) (Flare 6. 35) Connecting pipe (0. 33m) (For 10, 13 series ; Flare 9. 52 For 16 series ; Flare 12. 7) 235 215 For stud bolt (8~10) For stud bolt (6) 620 235 215 Minimum distance to ceiling 65 or more Hanger 26 48 45 275 190 Minimum distance to ceiling Minimum distance to ceiling 45 170 or more 170 or more Hanger 90 150 160 160 Hanger 32 40 57 18 90 150 Installation plate outline Center line Wireless remote control ­3­ 160 6 60 FILE NO. Indoor Unit (For 10k & 13k) COLOR INDICATION BRW RED WHI YEL BLU BLK GRY PNK ORN GRN&YEL GRN : : : : : : : : : : : BROWN RED WHITE YELLOW BLUE BLACK GRAY PINK ORANGE GREEN & YELLOW GREEN TERMINAL BLOCK 2 1 BLK W HI RED CN21 INDOOR OUTDOOR UNIT UNIT BLK BLK CN01 (BLU) CN24 CN23 HEAT EXCHANGER SENSOR CN03 (W HI) (TC) BLK BLK 11 22 LINE FILTER Power supply circuit 5 CN07 (W HI) +12 VDC +5 VDC FUSE THERMO SENSOR (TA) 11 22 T3. 15A 250VAC F01 R04 3 Fan Motor Drive circuit BLU BLU BLU BLU BLU BLU BLU BLU BLU BLU 10 10 10 10 WHI 11 11 11 11 INFRARED RAYS RECEIVING AND INDICATING PARTS 1 2 3 4 5 6 7 8 9 CN25 (W HI) 1 2 3 4 5 6 7 8 9 CN13 (W HI) 11 22 33 44 55 W HI YEL YEL YEL YEL 11 22 33 44 55 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 LOUVER MOTOR CN11 123 123 CN10 5 5 3 3 BLK 1 1 RED 6 YEL GRY BRW MAIN P. C. BOARD WP-004 150°C 123456 12345 6 AC FAN MOTOR MCC-861 1 4 1234 HA JEM-A CN08 Simple Check for Failure Diagnosis Check Item Diagnosis Result 1 Check to see if the OPERATION indicator goes on OPERATION and off when the main switch or breaker is turned on. INDICATOR (Check the primary and secondary voltage of the transformer. ) 2 Check the power supply voltage between 1 and 2 . [. . . ] Therefore, during installation work, be sure that water, dust, former refrigerant, or refrigerating machine oil does not enter into the refrigerating cycle or new-refrigerant air coditioner. To prevent mixin of refrigerant or refrigerating machine oil, the sizes of connecting sections of charging port of the main unit or installation tools are different from those for the coventional refrigerant. Accordingly, the exclusive tools are required for the new refrigerant (R-410A) as shown below. For conecting pipes, use new and clean piping materials with high pressure-tight force, which were made fro R-410A only, so that water or dust does not enter. Moreover, do not use the existing piping because there are problems about pressure-tight forec and inner impurity in the existing piping. CAUTION TO DISCONNECT THE APPLIANCE FROM THE MAIN POWER SUPPLY. This appliance must be connected to the main power supply by means of a circuit breaker or a switch with a contact separation of at least 3 mm. The installation fuse (25A) must be used for the power supply line of this air conditioner. DANGER · FOR USE BY QUALIFIED PERSONS ONLY. · TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK. IF THE CONNECTING CABLE IS CONNECTED BY WRONG WAY, ELECTRIC PARTS MAY BE DAMAGED. · CHECK THE EARTH WIRE IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION. · DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS. · TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY (MORE THAN 2 M) FROM HEAT SOURCES SUCH AS RADIATORS, HEAT REGISTORS, FURNACE, STOVES, ETC. It is necessary to use an adapter to prevent vacuum pump oil from flowing back to the charge hose. The charge hose connecting part has two ports-one for conventional refrigerant (7/16 UNF 20 threads per inch) and one for R410A. If the vacuum pump oil (mineral) mixes with R-410A a sludge may occur and damage the equipment. Exclusive for HFC refrigerant. Charge hose Electronic balance for refrigerant charging Torque wrench (nominal diam. 1/2, 5/8) Flare tool (clutch type) Gauge for projection adjustment Vacuum pump adapter Gas leakage detector · Incidentally, the "refrigerant cylinder" comes with the refrigerant designation (R-410A) and protector coating in the U. S's ARI specified rose color (ARI color code: PMS 507). · Also, the "charge port and packing for refrigerant cylinder" require 1/2 UNF 20 threads per inch corresponding to the charge hose's port size. ­ 25 ­ FILE NO. Installation Diagram of Indoor Units 65 mm or more 170 mm Hook or m ore 1 Installation plate For the rear left and left piping Wall Hoo k 170 mm or m ore Air filte r Insert the cushion between the indoor unit and wall, and tilt the indoor unit for better operation. Shield pipe (At tac h to the fron t pa nel . ) Do not allow the drain hose to get slack. 5 Sasa-Zeolite plus filter 6 Bio-enzyme & Gingko filte Cut the piping hole sloped slightly 8 Pan head wood screw Make sure to run the drain hose sloped downward. 2 Wireless remote control 4 Remote control holder Before installing the wireless remote control · With the remote control cover open, load the batteries supplied correctly, observing their polarity. The auxiliary piping can be connected the left, rear left, rear right, right, bottom right or bottom left. 2 Wireless remote control Cover Insulate the refrigerant pipes separately with insulation, not together. Right Rear right Rear left Left Bottom left Bottom right 3 Batteries 6 mm thick heat resisting polyethylene foam - 26 - FILE NO. Part name (Q'ty) Part No. Part name (Q'ty) 1 Installation plate x 1 4 Remote control holder x 1 7 Mounting screw 4 x 25 l x 6 2 Wireless remote control x 1 5 Sasa-Zeolite plus filter x 1 8 Pan head wood screw 3. 1 x 16 l x 2 3 Battery x 2 6 Bio-enzyme & Ginko filter x 1 9 B Label x 1 B Others Name Owner's manual Installation manual This model is not equipped with an extension drain hose. Option : For the extension drain hose, use an optionally available RB-821SW or commercially available one. ­ 27 ­ FILE NO. Installation Place · A place which provides the spaces around the indoor unit as shown in the above diagram. · A place where there is no obstacle near the air inlet and outlet. [. . . ] 3) First open the horizontal louver, and then remove the front panel from the back body by pulling it toward you. How to mount the front panel Push the front panel back in and make sure all hooks are locked. 2 Electrical part Remarks 2 2 2 2 4-Screws 3 How to remove the electrical part. 3) Disconnect the 2 connectors (3P) for the fan motor and the connector (5P) for the louver motor from the P. C. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-11LKX




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-11LKX will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.