User manual TOSHIBA RAS-10SKV2-E SERVICE MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAS-10SKV2-E. We hope that this TOSHIBA RAS-10SKV2-E user guide will be useful to you.


TOSHIBA RAS-10SKV2-E SERVICE MANUAL: Download the complete user guide (12593 Ko)

You may also download the following manuals related to this product:

   TOSHIBA RAS-10SKV2-E (775 ko)
   TOSHIBA RAS-10SKV2-E DOCUMENTATION COMMERCIALE (1112 ko)
   TOSHIBA RAS-10SKV2-E INSTALLATION MANUAL (3863 ko)

Manual abstract: user guide TOSHIBA RAS-10SKV2-ESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] SVM-10001 SERVICE MANUAL SPLIT TYPE Indoor Unit <High Wall, Heat Pump Type> Outdoor Unit <Heat Pump Type> RAS-10SKV2-E RAS-13SKV2-E RAS-16SKV2-E RAS-10SAV2-E RAS-13SAV2-E RAS-16SAV2-E R410A January, 2010 FILE NO. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] In order to prevent any other refrigerant from being charged, each port diameter has been changed. In order to increase pressure resisting strength, hose materials and port size have been changed (to 1/2 UNF 20 threads per inch). As pressure is high and gasification speed is fast, it is difficult to read the indicated value by means of charging cylinder, as air bubbles occur. Incidentally, a common wrench is used for nominal diameters 1/4 and 3/8. By increasing the clamp bar's receiving hole, strength of spring in the tool has been improved. Gauge manifold × × ¡ Charge hose Electronic balance for refrigerant charging Torque wrench (nominal diam. 1/2, 5/8) × ¡ -- -- Flare tool (clutch type) Gauge for projection adjustment Used when flare is made by using conventional flare tool. It is necessary to use an adapter to prevent vacuum pump oil from flowing back to the charge hose. The charge hose connecting part has two ports-one for conventional refrigerant (7/16 UNF 20 threads per inch) and one for R410A. If the vacuum pump oil (mineral) mixes with R410A a sludge may occur and damage the equipment. Vacuum pump adapter ¡ Gas leakage detector × Exclusive for HFC refrigerant. · Incidentally, the "refrigerant cylinder" comes with the refrigerant designation (R410A) and protector coating in the U. · Also, the "charge port and packing for refrigerant cylinder" require 1/2 UNF 20 threads per inch corresponding to the charge hose's port size. ­ 55 ­ FILE NO. Installation Place · A place which provides enough spaces around the indoor unit as shown in the diagram. · A place where there are no obstacle near the air inlet and outlet. · A place which allows easy installation of the piping to the outdoor unit. · The indoor unit shall be installed so that the top of the indoor unit is positioned at least 2m in height. · Also, avoid putting anything on the top of the indoor unit. 10-3-2. Drilling a Hole and Mounting Installation Plate Drilling a hole When install the refrigerant pipes from the rear. Pipe hole 65 mm CAUTION 100 mm · Direct sunlight on the indoor unit wireless receiver should be avoided. · The microprocessor in the indoor unit should not be too close to r-f sources. After determining the pipe hole position on the installation plate ( ð ) drill the pipe hole (Ø65 mm) at a slight downward slant to the outdoor side. Remote controller · Should be placed where there are no obstacles, such as curtains, that may block the signal. · Do not install the remote controller in a place exposed to direct sunlight or close to a heating source, such as a stove. · Keep the remote controller at least 1 m away from the nearest TV set or stereo equipment. (This is necessary to prevent image disturbances or noise interference. ) · The location of the remote controller should be determined as shown below. NOTE : · When drilling into a wall that contains a metal lath, wire lath or metal plate, be sure to use a pipe hole brim ring sold separately. Mounting the installation plate Anchor bolt holes Hook 62 82. 5 Indoor unit (Side view) (Top view) Indoor unit 170 85 Reception range Remote controller Reception range Remote controller Pipe hole Hook Indoor unit Hook Thread Weight Pipe hole Installation plate 1 7 Mounting screw Fig. SVM-10001 When the installation plate is directly mounted on the wall 1. Securely fit the installation plate onto the wall by screws with the upper and lower catches, that hold the indoor unit, facing out. [. . . ] SVM-10001 No. 11 Part name Procedure Remarks TE sensor (outdoor heat exchanging temperature sensor) · Attachment Install the sensor onto the straight pipe part of the condenser output pipe. Arrow D Detail B Detail A Detail C Detail C for 10k Detail C for 13, 16k 12 TS sensor (Suction pipe temperature sensor) · Attachment Install the senser onto the straight pipe part of the suction pipe. Be careful for the lead direction of the sensor. · Shown in the above figure is the model 16k. · The sensor mounting positions in the model 10, 13k are all the same witth the sole exception of the TE sensor. Refer to the figure shown on the left. 13 TD sensor (Discharge pipe temperature sensor) · Attachment With its leads pointed upward, install the sensor onto the vertical straight pipe part of the discharge pipe. Detail A TS Sensor For 13k 14 TO sensor (Outside air temperature sensor) · Attachment Insert the outdoor air temperature sensor into the holder, and install the holder onto the heat exchanger. Detail B TD Sensor For 13k Detail A TS sensor For 10, 16k Detail B TD sensor For 10, 16k Arrow D TO sensor TO sensor holder CAUTION During the installation work (and on its completion), take care not to damage the coverings of the sensor leads on the edges of the metal plates or other parts. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-10SKV2-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-10SKV2-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.