User manual TOSHIBA RAS-10JKVP-E PSD

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAS-10JKVP-E. We hope that this TOSHIBA RAS-10JKVP-E user guide will be useful to you.


TOSHIBA RAS-10JKVP-E PSD: Download the complete user guide (46 Ko)

Manual abstract: user guide TOSHIBA RAS-10JKVP-EPSD

Detailed instructions for use are in the User's Guide.

[. . . ] CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT CYCLE DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · Insert clip anchors for the g mounting screws. NOTE · Install the installation plate using between 4 to 6 mounting screws, being sure to secure all four corners. Electrical Work 1. The supply voltage must be the same as the rated voltage of the air conditioner. Prepare a power source for the exclusive use of the air conditioner. NOTE · Wire type: More than H07RN-F or 245IEC66 (1. 0 mm2 or more) ­ 52 ­ CAUTION · This appliance can be connected to a main circuit breaker in either of the following two ways. (1) Connection to fixed wiring: A switch or circuit breaker which disconnects all poles and has a contact separation of at least 3 mm must be incorporate in the fixed wiring. (2) Connection with power supply plug: Attach power supply plug with power cord and plug it into wall outlet. An approved power supply cord and plug must be used. NOTE · Perform wiring work being sure the wire length is long enough. Wiring Connection How to connect the connecting cable Wiring the connecting cable can be carried out without removing the front panel. Insert the connecting cable (or as according to local regulations/codes) into the pipe hole on the wall. Pull the connecting cable through the cable slot on the rear panel so that it protrudes about 15 cm out of the front. Insert the connecting cable fully into the terminal block and secure it tightly with screws. Attach the terminal cover, rear plate bushing and air inlet grille on the indoor unit. CAUTION · Be sure to refer to the wiring system diagram labeled inside the front panel. · Check local electrical regulations for any specific wiring instructions or limitations. Terminal cover Screw Screw Cord clamp Terminal block Terminal block NOTE Wire type: More than H07RN-F or 245IEC66 (1. 0 mm2 or more) Earth wire Connecting cable 70 mm 10 mm Earth line Connecting cable 10 mm about 15 cm 50 mm ­ 53 ­ Piping and Drain Hose Installation Piping and drain hose forming · Since condensation results in machine trouble, make sure to insulate both the connecting pipes separately. Run the drain hose at a downward sloped angle. NOTE · Hole should be made at a slight downward slant on the outdoor side. Do not route the drain hose upwards. Do not form the drain hose into a waved shape. 50 mm or more Do not put the drain hose end into water. Do not put the drain hose end in a drainage ditch. 2. 3. Put water in the drain pan and make sure that the water is being drained outside. When connecting extension drain hose, insulate the connection part of extension drain hose with shield pipe. Shield pipe Drain hose Inside the room Extension drain hose CAUTION Install the drain pipe for proper drainage. This air conditioner has been designed to drain water collected from condensation which forms on the back of the indoor unit, to the drain pan. Therefore, do not locate the power cord and other parts at a height above the drain guide. Wall Drain guide Space for pipes ­ 56 ­ 10-4. Installation of Outdoor Unit Installation Location A place which provides enough space around the outdoor unit as shown in the diagram. A place which can bear the weight of the outdoor unit and does not allow an increase in noise level and vibration. A place where the operation noise and discharged air do not disturb neighbors. When the outdoor unit is to be installed in an elevated position, be sure to secure its feet. This air conditioner accepts a connection piping length of up to 25 m. [. . . ] * If the drain port is frozen due to installation status, etc. , draw around the cord heater so that the end part of the heater is inserted into the drain port. In this case, add some fixing positions to fix the cord heater surely. When there is the heating part near the electric parts box, a fire may generate. Be sure to set the heating part on the outdoor unit base plate at the fan room side or near it. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-10JKVP-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-10JKVP-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.