User manual TOSHIBA RAS-107SKV-E2 SERVICE MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAS-107SKV-E2. We hope that this TOSHIBA RAS-107SKV-E2 user guide will be useful to you.


TOSHIBA RAS-107SKV-E2 SERVICE MANUAL: Download the complete user guide (10975 Ko)

Manual abstract: user guide TOSHIBA RAS-107SKV-E2SERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] SVM-09051 SERVICE MANUAL SPLIT TYPE Indoor Unit <High Wall, Heat Pump Type> Outdoor Unit <Heat Pump Type> RAS-107SKV-E2 RAS-107SAV-E2 R410A March, 2009 FILE NO. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Motions The green indicator is on. The unit beeps three times. If the unit is required to operate at this time, press [RESET] button once more or use the remote controller to turn it on. RESET button While the filter check indicator is on, the RESET button has the function of filter reset betton. 39 FILE NO. How to Cancel the Auto Restart Function To cancel auto restart function, proceed as follows : Repeat the setting procedure : the unit receives the signal and beeps three times. The unit will be required to be turned on with the remote controller after the main power supply is turned off. When the system is on stand-by (not operating) Operation Press [RESET] button for more than three seconds. three seconds, Motions The unit beeps three times and continues to operate. If the unit is not required to operate at this time, press [RESET] button once more or use the remote controller to turn it off. RESET button When the system is operating Operation Press [RESET] button for more than three seconds. three seconds, Motions The green indicator is on. The unit beeps three times. If the unit is required to operate at this time, press [RESET] button once more or use the remote controller to turn it on. RESET button 9-3-3. Power Failure During Timer Operation When the unit is turned off because of power failure during timer operation, the timer operation is cancelled. In that case, set the timer operation again. NOTE : The Everyday Timer is reset while a command signal can be received from the remote controller even if it stopped due to a power failure. 40 FILE NO. Remote control and its functions 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Infrared signal emitter 1 Set louver button (FIX) Auto louver button (SWING) Mode select button (MODE) Reset button (RST) On timer button (ON) Off timer button (OFF) Reserve button (SET) Cancel button (CLR) Check button (CHK) ECO button (ECO) Fan speed button (FAN) Start/Stop button (START/STOP) Temperature button ( ) 2 3 4 5 6 7 SWING MODE TOSHIBA MODE AUTO COOL DRY HEAT TEMP . B Hr. ON OFF FA N AUTO QUIET TEMP . 14 13 FA N ECO STAR T/STOP FIX RST CHK TIMER ON OFF SET CLR 12 11 10 9 8 9-4-2. AUTOMATIC OPERATION To automatically select cooling, heating, or fan only operation. DRY OPERATION (COOLING ONLY) For dehumidification, a moderate cooling performance is controlled automatically. ECO OPERATION To automatically control room to save energy (except in DRY mode) Press ECO : Start and stop the operation. Note: Cooling operation; the set temperature will increase automatically 1 degree/ hour for 2 hours (maximum 2 degrees increase). TEMPORARY OPERATION In case of the misplaced or discharged remote control Pressing the RESET button, the unit can start or stop without using the remote control. Operation mode is set on AUTOMATIC operation, preset temperature is 24C and fan operation is automatic speed. TIMER OPERATION Setting the ON Timer Setting the OFF Timer Press Press Press TIMER OFF : Set the desired ON timer. TIMER CLR : Cancel the timer. RESET button 1 2 3 Press Press Press TIMER ON : Set the desired ON timer. TIMER CLR : Cancel the timer. Note: Keep the remote control in accessible transmission to the indoor unit; otherwise, the time lag of up to 15 minutes will occur. AUTO RESTART OPERATION To automatically restart the conditioner after the power failure (Power of the unit must be on. ) Setting 1. Press and hold the RESET button on the indoor unit for 3 seconds to set the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5 secpmds) Do not operate ON timer and OFF timer. [. . . ] Lead wires Connection with terminal block : 3 wires (Black, White, Orange) Connection with compressor : remove the connector (3P) Connection with reactor : remove the connector (2P) 2. Connectors (6 positions) CN300, CN703 : Outdoor fan (3P: white)* (See Note 1) CN701 : 4 way valve (3P: Yellow)* CN601 : TD sensor (2P: White) CN602 : TO sensor (2P: White) CN500 : Case thermo (2P: White) Note 1) As the connector has a stopper, release the housing lock when removing. Note 2) Hold the housing (resin part) with stopper and pull out to remove. Note 2) Remove the claw of the board support fixed to the inverter board, and remove upwards holding the heat sink. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-107SKV-E2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-107SKV-E2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.