[. . . ] SPECIFICATIONS MODEL RAS-13UKHP-E4 / RAS-13UAH-E4 RAS-13UKP-E4 / RAS-13UA-E4 ITEM Capacity 220 V kW Phase Power source Power consumption Power factor Running current Indoor Outdoor V Hz kW % A A A lit/h dB 49 5. 50 1. 23 99 3. 55 Cooling 240 V 3. 60 220 V 4. 10 Heating 240 V 4. 15 1Æ 220 - 240 50 1. 27 97 5. 30 25 2. 0 41/35/31 51 1. 00 Capillary tube Æ12. 7 Flare connection Æ6. 35 Flare connection 49 R22 51 47 1. 26 98 0. 15 5. 35 5. 15 5. 75 1. 33 96 1. 24 98 220 V 3. 70 Cooling 240 V 3. 75 1. 28 95 5. 60 24 Starting current Moisture removal Noise Refrigerant Indoor (H/M/L) Name of refrigerant Rated amount Gas side size Connection type Liquid side size Interconnection Connection type pipe Maximum length (One way) Maximum height difference INDOOR UNIT Outdoor (220 - 240 V) dB kg mm mm 48 0. 80 Refrigerant control m m RAS-13UKHP-E4 15* 6 1 RAS-13UKP-E4 Height Dimensions Net weight Evaporator type Indoor fan type High fan Air volume Medium fan Low fan Fan motor output Air filter OUTDOOR UNIT mm mm mm kg 275 790 208 10 Finned tube Cross flow fan Width Depth m3/h m /h 3 630 520 430 650 550 490 20 Honeycomb woven filter with PP frame RAS-13UAH-E4 630 520 430 m3/h W RAS-13UA-E4 Height Dimensions Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Safety device Louver type Usable outdoor temperature range Model Output Width Depth mm mm mm kg 37 550 780 270 34 Finned tube Propeller fan m /h 3 2120 2200 42 2120 2200 2030 30 2150 W W PH225X2C-4FT 1100 Fuse, Overload relay Automatic louver °C 15 ~ 43 -10 ~ 24 15 ~ 43 ­3­ FILE NO. SVM-05001 MODEL RAS-10UKHP-E4 / RAS-10UAH-E4 RAS-10UKP-E4 / RAS-10UA-E4 ITEM Capacity 220 V kW Phase Power source Power consumption Power factor Running current Indoor Outdoor V Hz kW % A A A lit/h dB 47 4. 30 0. 93 95 2. 65 Cooling 240 V 2. 70 220 V 2. 95 Heating 240 V 3. 00 1Æ 220 - 240 50 0. 98 92 4. 27 0. 84 94 0. 15 3. 90 19 1. 2 39/33/26 49 0. 76 Capillary tube Æ9. 52 Flare connection Æ6. 35 Flare connection 47 R22 49 44 3. 77 3. 60 0. 86 91 0. 80 97 220 V 2. 65 Cooling 240 V 2. 70 0. 85 95 3. 58 16 Starting current Moisture removal Noise Refrigerant Indoor (H/M/L) Name of refrigerant Rated amount Gas side size Connection type Liquid side size Interconnection Connection type pipe Maximum length (One way) Maximum height difference INDOOR UNIT Outdoor (220 - 240 V) dB kg mm mm 45 0. 68 Refrigerant control m m RAS-10UKHP-E4 10*1 5 RAS-10UKP-E4 Height Dimensions Net weight Evaporator type Indoor fan type High fan Air volume Medium fan Low fan Fan motor output Air filter OUTDOOR UNIT mm mm mm kg 275 790 208 10 Finned tube Cross flow fan Width Depth m3/h m /h 3 570 460 340 610 520 400 20 Honeycomb woven filter with PP frame RAS-10UAH-E4 610 460 340 m3/h W RAS-10UA-E4 Height Dimensions Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Safety device Louver type Usable outdoor temperature range Model Output Width Depth mm mm mm kg 32 550 780 270 31 Finned tube Propeller fan m /h 3 1740 1850 1740 20 1850 1740 1850 W PH180X1C-4DZDN3 W RM5510GNE94 750 Fuse, Overload relay Automatic louver °C 15 ~ 43 -10 ~ 24 15 ~ 43 -4- FILE NO. SVM-05001 MODEL ITEM Capacity kW Phase Power source Power consumption Power factor Running current Indoor Outdoor V Hz kW % A A A lit/h dB 44 45 0. 60 Capillary tube mm mm 9. 52 Flare connection 6. 35 Flare connection m m 10*1 5 45 46 R-22 kg 0. 57 2. 69 2. 77 13 0. 8 38/32/26 44 45 44 45 2. 35 2. 40 0. 61 98 0. 68 97 0. 54 98 0. 59 96 0. 15 2. 55 2. 55 11 2. 55 2. 55 2. 00 RAS-07UKHP-E4/ RAS-07UAH-E4 Cooling 220V 240V 2. 05 2. 00 RAS-07PKH/ RAS-07UA-E4 Cooling 220V 2. 10 1 220 - 240 50 0. 58 98 0. 62 96 240V 2. 15 2. 05 240V RAS-07UKPX4/ RAS-07UAX4 Cooling 220V 2. 10 240V 2. 15 Heating 220V 0. 58 98 0. 62 96 Starting current Moisture removal Noise Indoor (H/M/L) Name of refrigerant Rated amount Gas side size Connection type Liquid side size Interconnection Connection type pipe Maximum length (One way) Maximum height difference Outdoor (220-240V) dB Refrigerant Refrigerant control INDOOR UNIT Height Dimensions Net weight Evaporator type Indoor fan type High fan Air volume Medium fan Low fan Fan motor output Air filter m3/h m3/h m3/h W 570 460 340 Width Depth mm mm mm kg RAS-07UKHP-E4 275 790 208 10 Finned tube RAS-07PKH RAS-07UKPX4 Cross flow fan 610 490 400 20 Honeycomb woven filter with PP frame 570 460 340 OUTDOOR UNIT Height Dimensions Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Safety device Louver type Usable outdoor temperature range °C 15 ~ 43 Model Output W m3/h W 1280 Width Depth mm mm mm kg RAS-07UAH-E4 530 660 240 28 Finned tube Propeller fan 1360 1280 1360 20 RAS-07UA-E4 RAS-07UAX4 27 1280 1360 1280 1360 PH108X1C-4DZDN2 605 Fuse, Overload relay Automatic louver -10 ~ 24 15 ~ 43 21 ~ 43 ­5­ FILE NO. SVM-05001 ITEM Capacity MODEL RAS-13UKPX4 / RAS-13UAX4 RAS-12UKPX4 / RAS-12UAX4 Cooling 220 V 240 V 3. 75 220 V 3. 40 1Æ 220 - 240 50 1. 24 98 5. 60 1. 28 95 5. 45 24 2. 0 41/35/31 47 48 0. 80 Capillary tube Æ12. 70 Flare connection 47 R22 48 1. 24 98 0. 15 5. 60 5. 45 1. 28 95 240 V 3. 48 RAS-10UKPX4 / RAS-10UAX4 220 V 2. 65 240 V 2. 70 kW Phase V Hz kW % Indoor Outdoor A A A lit/h dB dB kg mm mm 3. 70 Power source Power consumption Power factor Running current 0. 80 97 3. 60 16 1. 2 39/33/26 44 0. 68 Æ9. 52 0. 85 95 3. 58 Starting current Moisture removal Noise Refrigerant Indoor (H/M/L) Outdoor Name of refrigerant Rated amount Gas side size Connection type Liquid side size Interconnection Connection type pipe Maximum length (One way) Maximum height difference INDOOR UNIT Height Dimensions Net weight Evaporator type Indoor fan type High fan Air volume Medium fan Low fan Fan motor output Air filter OUTDOOR UNIT Height Dimensions Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Safety device Louver type Usable outdoor temperature range Model Output Width Depth Width Depth 45 Refrigerant control 6. 35 Flare connection m m RAS-13UKPX4 15* 1 6 RAS-12UKPX4 275 790 208 10 Finned tube Cross flow fan 10* 1 5 RAS-10UKPX4 mm mm mm kg m3/h m /h m3/h W RAS-13UAX4 3 630 520 430 20 Honeycomb woven filter with PP frame RAS-12UAX4 550 780 270 34 Finned tube Propeller fan 610 460 340 RAS-10UAX4 mm mm mm kg 31 m /h W W 3 2030 2150 30 2030 2150 1740 20 1850 PH225X2C-4FT 1100 Fuse, Overload relay Automatic louver RM5510GNE94 750 °C 21 ~ 43 -6- FILE NO. [. . . ] Insert the connecting cable fully into the terminal block and secure it tightly with screws. Fix the terminal cover, rear plate bushing and air inlet grille on the indoor unit. Connecting cable For RAS-13/10/07UKP Terminal cover Cord clamp Terminal block Screw 12 12 abo ut 1 5 cm Earth line Screw Screw Connecting cable Fig. 8-4-7 Earth line 60 mm 10 mm CAUTION · Be sure to refer to the wiring system diagram labeled inside the front panel. · Check local electrical cords and also any specific wiring instructions or limitations. For RAS-13/10/07UKHP Terminal cover Connecting cable abo 10 mm 50 mm Stripping length of the connecting cable Fig. 8-4-8 Terminal block Cord clamp Screw 4 NOTE · Use stranded wire only. · Wire type : H07 RN-F or more <How to install the air inlet grille on the indoor unit> · When attaching the air inlet grille, the contrary of the removed operation is performed. 4 12 3 12 3 ut 1 5 cm Earth line Screw Screw Connecting cable Fig. 8-4-9 10 mm 50 mm Stripping length of the connecting cable Fig. Piping and drain hose installation <Piping and drain hose forming> * Since dewing results in a machine trouble, make sure to insulate both the connecting pipes. (Use polyethylene foam as insulating material. ) Rear right 4 mm How to fix the drains cap 1) Insert hexagonal wrench (4 mm) in a center head. Left Bottom right Right Die-cutting Front panel slit Bottom left Changing drain hose Rear left Piping preparation Fig. 8-4-12 2) Firmly insert drains cap. No gap Do not apply lubricating oil (refrigerant machine oil) when inserting the drain cap. Installation place · A place which provides the spaces around the outdoor unit as shown in the left diagram. · A place which can bear the weight of the outdoor unit and does not allow an increase in noise level and vibration. · A place where the operation noise and discharged air do not disturb your neighbors. · When the outdoor unit is to be installed in an elevated position, be sure to secure its feet. · An allowable length of the connecting pipe is up to 10 m (RAS-07, 10UA) or 15 m (RAS-12, 13UA). · An allowable height level is up to 5 m (RAS-07, 10UA) or 6 m (RAS-12, 13UA). · A place where the drain water does not raise any problem. Do not form the drain hose into a wavy shape. Do not put the drain hose end into water. Do not put the drain hose end in the drainage ditch. Fig. Put water in the drain pan and make sure that the water is drained out of doors. When connecting extension drain hose, insulate the connecting part of extension drain hose with shield pipe. Shield pipe CAUTION 1. Install the outdoor unit without anything blocking the air discharging. When the outdoor unit is installed in a place exposed always exposed to strong wind like a coast or on a high storey of a building, secure the normal fan operation using a duct or a wind shield. [. . . ] 43T60001 43T60002 43T69004 43T69005 43T69079 Description TERMINAL TERMINAL BLOCK; 3P SENSOR;HEAT EXCHANGER SENSOR;THERMOSTAT PC BOARD ASSY;WRS-LED Location No. 43T60077 43T62003 43T69430 43T69431 43T69432 Description FUSE, TEMPERATURE, 73°C CORD CLAMP PC BOARD (For RAS-07UKHP-E4) PC BOARD (For RAS-10UKHP-E4) PC BOARD (For RAS-13UKHP-E4) - 80 - FILE NO. 43T60002 43T69371 43T69005 43T69079 43T60077 43T69364 Description TERMINAL BLOCK; 3P TC SENSOR SENSOR;THERMOSTAT PC BOARD ASSY;WRS-LED FUSE, TEMPERATURE, 73°C (For UKP-E4) FUSE, TEMPERATURE (For UKPX4) Location No. 43T62003 43T69365 43T69366 43T69367 43T69361 Description CORD CLAMP PC BOARD (For RAS-07PKH/UKPX4) PC BOARD (For RAS-10UKP-E4/UKPX4) PC BOARD (For RAS-13UKP-E4/UKPX4, RAS-12UKPX4) TRANSFORMER(TT-10) - 81 - FILE NO. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-07PKH




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-07PKH will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.