User manual TOSHIBA D1334B2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA D1334B2. We hope that this TOSHIBA D1334B2 user guide will be useful to you.


TOSHIBA D1334B2 : Download the complete user guide (0 Ko)

Manual abstract: user guide TOSHIBA D1334B2

Detailed instructions for use are in the User's Guide.

[. . . ] Specifications 1-way (2 series) Air Discharge Cassette Type 50Hz Model name MMUAP0152SH AP0182SH AP0242SH Cooling/Heating capacity (kW) 4. 5/5. 0 5. 6/6. 3 7. 1/8. 0 Electrical Power supply 1 phase 50Hz 230V (220-240V) characteristics Running current (A) 0. 34 0. 37 0. 62 Power consumption (kW) 0. 042 0. 046 0. 075 Starting current (A) 0. 51 0. 54 0. 80 Appearance Main unit Heat-insulating material attached Zinc hot dipping steel plate Ceiling panel RBC-US21PGE Panel color Moon white (Muncel 2. 5GY9. 0/0. 5) Dimension Main unit Height (mm) 200 Width (mm) 1000 Depth (mm) 710 Ceiling panel Height (mm) 20 Width (mm) 1230 Depth (mm) 800 Total weight Main unit (kg) 21 22 Ceiling panel (kg) 5. 5 Heat exchanger Finned tube Soundproof / Heat-insulating material Polyethylene foam + Expanded polystyrene Fan Centrifugal fan (Sirocco fan) 3 Standard air flow High (m /h) 750 780 1140 (Mid. /Low) (m3/h) 690/630 720/660 960/810 Motor (W) 30 Air filter Standard filter attached (Long life filter) Controller Remote controller Connecting pipe Gas pipe (mm) 12. 7 15. 9 Liquid pipe (mm) 6. 4 9. 5 Drain pipe (Nominal dia. mm) 25 (Polyvinyl chloride tube : External dia. 32 Internal dia. 25) Sound pressure level High/Mid. /Low (dB(A)) 37/35/32 38/36/34 45/41/37 1 1. [. . . ] Dimensions 1-way (2 series) Air Discharge Cassette Type (MMU-AP***SH) Wire inlet (Knockout hole) 252 112 Fresh air inlet (Ø92 knockout hole) Ø112 (4-tapping screw under-hole) 248 Drain pipe connecting port (Be sure to connect the attached flexible hose. ) 72 20 C/L 56 Wire inlet 233 100 760 Ceiling opening size 475 Hanging bolt pitch 710 Unit external size C/L 800 Panel external size 122 220 20 1190 Ceiling opening size 1230 Panel external size 20 20 1060 Hanging bolt pitch 135 216 80 60 43 94 154 1000 Unit external size 706 Refrigerant pipe connecting port Gas side B Refrigerant pipe connecting port Liquid side A Hanging bolt M10 or W3/8 (Local supply) 200 93 Lower surface of ceiling 20 Ceiling panel (Sold separately) For front air discharge unit (Sold separately) knockout hole Wired remote controller (RBC-AMT31E) 4 Model name MMUAP015, AP018 type AP024 type 73. 4 76 A Ø6. 4 Ø9. 5 B Ø12. 7 Ø15. 9 2. 7 120 120 16 3 3. Electrical current characteristics 1-way (2 series) Air Discharge Cassette Type Type S-MMS (50Hz) Model D1334B2 MMU-AP0182SH MMU-AP0242SH D1334B2 MMU-AP0182SH MMU-AP0242SH D1334B2 MMU-AP0182SH MMU-AP0242SH Nominal Voltage Voltage Range (V-Ph-Hz) Min Max 230-1-50 198 264 230-1-50 198 264 230-1-50 198 264 220-1-60 220-1-60 220-1-60 230-1-50 230-1-50 230-1-50 198 198 198 198 198 198 264 264 264 264 264 264 Fan Motor kW FLA 0. 030 0. 40 0. 030 0. 42 0. 030 0. 71 0. 030 0. 030 0. 030 0. 030 0. 030 0. 030 0. 40 0. 45 0. 75 0. 40 0. 42 0. 71 Power Supply MCA MOCP 0. 49 15 0. 53 15 0. 88 15 0. 50 0. 57 0. 94 0. 49 0. 53 0. 88 15 15 15 15 15 15 S-MMS (60Hz) S-HRM 4 4. Sensible capacity table 1-way (2 series) Air Discharge Cassette Type (MMU-AP***SH) TC : Total capacity [kW] SHC : Sensible capacity [kW] Indoor air temp. 18. 0CWB 19. 0CWB 20. 0CWB 22. 0CWB 24. 0CWB 26CDB 27CDB 28CDB 30CDB 32CDB TC SHC TC SHC TC SHC TC SHC TC SHC 4. 4 4. 4 4. 4 4. 4 4. 4 4. 4 4. 4 4. 4 4. 4 4. 4 4. 4 4. 4 4. 4 4. 4 4. 2 4. 1 5. 4 5. 4 5. 4 5. 4 5. 4 5. 4 5. 4 5. 4 5. 4 5. 4 5. 4 5. 4 5. 4 5. 4 5. 3 5. 1 6. 9 6. 9 6. 9 6. 9 6. 9 6. 9 6. 9 6. 9 6. 9 6. 9 6. 9 6. 9 6. 9 6. 9 6. 7 6. 5 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 1 3. 0 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 8 3. 7 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 4. 9 4. 7 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 5 4. 4 4. 2 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 6 5. 4 5. 3 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 7. 1 6. 9 6. 7 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 1 3. 0 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 8 3. 7 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 4. 8 4. 7 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 6 4. 5 4. 4 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 8 5. 6 5. 4 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 3 7. 1 6. 9 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 1 3. 0 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 8 3. 7 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 4. 8 4. 7 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 9 4. 7 4. 6 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 6. 1 5. 9 5. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 7 7. 5 7. 3 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 1 3. 0 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 7 3. 6 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 5. 0 4. 8 4. 7 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 1 5. 0 4. 8 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 4 6. 2 6. 0 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 8. 1 7. 8 7. 6 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 0 2. 9 3. 8 3. 8 3. 8 3. 8 3. 8 3. 8 3. 8 3. 8 3. 8 3. 8 3. 8 3. 8 3. 8 3. 8 3. 7 3. 6 4. 8 4. 8 4. 8 4. 8 4. 8 4. 8 4. 8 4. 8 4. 8 4. 8 4. 8 4. 8 4. 8 4. 8 4. 7 4. 6 Unit Outdoor size air temp. However, please make a fresh air volume within 20% of standard. Model name Standard air flow MMU(m3/h) AP0152SH 750 AP0182SH 780 AP0242SH 1140 Provide an air filter in fresh air duct. (Fresh air doesn't pass through the filter of Indoor unit. ) Be sure to insulate the fresh air duct. Please wire for inter - lock with fan of Heat exchanger unit and Indoor unit. 80 70 D1334B2, MMU-AP182SH Static Pressure (Pa) 60 50 40 30 20 10 0 0 50 100 150 200 250 MMU-AP0242SH Fresh Air Volume (m3/h) Indoor unit Duct fan motor Fresh Air Volume Flange Option :TCB-FF101URE Inter - lock circuit Connect the driving relay of the duct fan(DC 12V) between 1 and 6 on the indoor P. C. (Rated current of the relay for duct fan shall be up to 75mA. ) After installation, implement a trial operation to check that the duct fan of the indoor unit start/stop simultaneously. [. . . ] (Implement the trial operation following to the installation manual of the indoor unit. ) 9 9. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA D1334B2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA D1334B2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.