User manual TOSHIBA BMS-CM1280TLE INSTALLATION MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA BMS-CM1280TLE. We hope that this TOSHIBA BMS-CM1280TLE user guide will be useful to you.


TOSHIBA BMS-CM1280TLE INSTALLATION MANUAL: Download the complete user guide (582 Ko)

You may also download the following manuals related to this product:

   TOSHIBA BMS-CM1280TLE (1291 ko)
   TOSHIBA BMS-CM1280TLE INSTALLATION MANUAL (1114 ko)

Manual abstract: user guide TOSHIBA BMS-CM1280TLEINSTALLATION MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] * When attaching the clamp filter, be sure to pass the communication wire twice through the clamp filter as shown below. TCC-LINK wire RS-485 wire LAN cable Remove and insert the wire while pressing the upper button with a screwdriver. 5-EN ­6­ Compliant Manager Installation Manual <Connections to External Equipment> Designation Input/ Output item Compliant Manager side Input/output conditions Alarm output Run output Non-voltage "A" contacts Static (Relay output) Allowable contact voltage/current 30 VDC, 0. 3 A +12V External equipment side Demarcation terminal Example of circuit Input/output conditions Terminal name 0. 4 to 1. 2 Ø Alarm Run Digital input Wiring length: 100 m or less Status output Output common 0. 4 to 1. 2 Ø Digital input/output terminals All stop input All start input Fire alarm input Voltage-applied "A" contacts All stop: Pulse or static All start: Pulse or static Fire alarm: Static (Photocoupler input) * Select nonvoltage contacts that allow minute current (12V, 1mA) COM All stop (+) (Pulse or static) All start (+) (Pulse or static) Control input Pulse width: 300 ms or more Wiring length: 100 m or less Fire alarm (+) (Static) Input common (­) *Wire the cable so that the user should not touch the electricity port directly. <Specifications for Wiring> Use the following materials to connect signal lines and power lines (procured on site) No 1 Line Type For TCC-LINK Wire size Length Type 2 For RS-485 Wire size Length Type 3 For Power Wire size Length Type 4 For Digital Input/Output connection Wire size Length Description 2-core shield wire 1. 25mm², 1000m max. (total length) H07 RN-F or 245IEC66 0. 75mm², 50m max. 227IEC75 (2-wire) 0. 5mm², 100m max. ­7­ 6-EN Compliant Manager Installation Manual 5 MODE SETTING FOR THE CONTROLLER Operation mode Use SW1-<6> for the operation mode setting. OFF side: Central control mode This Compliant Manager is used as a central control unit. [. . . ] NOTE If the address setting is made before the initial communication is completed, an address is not assigned to some units. · Connect terminals U1 and U2 in the outdoor unit (Header unit) to the relay connector of terminals U3 and U4. board of the outdoor unit (Header unit) to ON only for one system, and to OFF for others. * The location of SW30 is shown in the wiring diagram supplied with the outdoor unit. <Setting central control addresses (group numbers)> Use "manual setting from wired remote controller, " "manual setting, " or "automatic setting" to set central control addresses. A Manual setting from wired remote controller Set central control addresses (group numbers) from a standard wired remote controller. * The following setting procedure is described based on button operations of the wired remote controller RBCAMT32E or RBC-AMT31E. (1) Press the button and button simultaneously for at least 4 seconds. (Note: Do not press the button during setting. ) (2) Press the button to change the CODE No. · Group numbers used for the Compliant Manager are central control addresses (DN item 03). * This setting procedure may vary depending on the wired remote controller model. * Perform these steps while air conditioners are not working. 13-EN ­ 14 ­ Compliant Manager Installation Manual B Manual setting Set central control addresses (group numbers) manually from the Compliant Manager. (1) Press the button and ZONE button simultaneously for at least 4 seconds. (3) Select the line on which the unit exists and the zone and group in which addresses are to be registered with the LINE button, ZONE and buttons, and GROUP and buttons. · When a zone is selected, group numbers registered in the zone are displayed. · Even when addresses have been registered, the registration can be cancelled with the button. (4) Select the unit to be registered in the group selected in step (3). · Switch refrigeration system No. 1 to 31 with the button, and then switch indoor unit No. 1 to 64 with the button. · When no system exists, indoor unit number is displayed as "- -". · System number 31 is for a local adapter and heat exchange ventilators. An indoor unit number is always displayed regardless of whether the unit exists or not. (5) Press the button to register the setting or press the button to cancel the setting. [. . . ] setting change mode is exited. 17-EN ­ 18 ­ Compliant Manager Installation Manual LINE 1 ZONE GROUP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Indoor unit No. Installation place ZONE GROUP 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Indoor unit No. Installation place ­ 19 ­ 18-EN Compliant Manager Installation Manual LINE 2 ZONE GROUP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Indoor unit No. Installation place ZONE GROUP 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Indoor unit No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA BMS-CM1280TLE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA BMS-CM1280TLE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.