User manual TOSHIBA AS200

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA AS200. We hope that this TOSHIBA AS200 user guide will be useful to you.


TOSHIBA AS200 : Download the complete user guide (2112 Ko)

You may also download the following manuals related to this product:

   TOSHIBA AS200 (2617 ko)
   TOSHIBA AS200 (2095 ko)
   TOSHIBA AS200 (2389 ko)
   TOSHIBA AS200 (2135 ko)
   TOSHIBA AS200 (2138 ko)
   TOSHIBA AS200 (2134 ko)
   TOSHIBA AS200 (2133 ko)
   TOSHIBA AS200 (2304 ko)
   TOSHIBA AS200 (2131 ko)
   TOSHIBA AS200 (2141 ko)
   TOSHIBA AS200 (2099 ko)
   TOSHIBA AS200 (2388 ko)
   TOSHIBA AS200 (2102 ko)
   TOSHIBA AS200 (2110 ko)
   TOSHIBA AS200 (5662 ko)

Manual abstract: user guide TOSHIBA AS200

Detailed instructions for use are in the User's Guide.

[. . . ] CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT CYCLE DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] (When the remote controller setting is "A", there is no indication at this position. ) 7 8 9 10 1 3 4 2 8 10 AUTO 9 7 5 6 · In the illustration, all indications are shown for purposes of explanation. During operation, only the relevant indicators are shown on the remote controller. ­ 70 ­ 9-6. Hi-POWER Mode ([Hi-POWER] button on the remote controller is pressed) When [Hi-POWER] button is pressed while the indoor unit is in Auto, Cooling or Heating operation, Hi-POWER mark is indicated on the display of the remote controller and the unit operates as follows. 1. Automatic operation · The indoor unit operates in according to the current operation. (The value of the preset temperature on the remote controller does not change. ) · If the difference between the preset temperature and the room temperature is big, the horizontal louver moves to the Hi-POWER position automatically. Then when the difference between them gets smaller, the horizontal louver returns automatically. (The value of the preset temperature on the remote controller does not change. ) 4. Intermittent Operation Control for Indoor Fans of the Indoor Unit at Thermo-off Side in Heating Operation While heating operation is executed in two rooms, if room temperature reached the setup temperature in one room and thermo-off occurred, the following operations start. The indoor unit of the room (A room) in which thermo-off did not occur starts a continuous operation with the setup number of revolution. The indoor unit of the room (B room) in which thermo-off occurred starts intermittent operation of the indoor fan. However if temperature of the indoor heat exchanger becomes over 55°C or more in B room, the indoor fan stops the intermittent operation and starts continuous operation. · A place which allows easy installation of the piping to the outdoor unit. · The indoor unit shall be installed so that the top of the indoor unit is positioned at least 2m in height. · Also, avoid putting anything on the top of the indoor unit. 10-3-2. Drilling a Hole and Mounting Installation Plate Drilling a hole When install the refrigerant pipes from the rear. The center of the pipe hole Pipe hole 65 42 mm mm CAUTION · Direct sunlight on the indoor unit wireless receiver should be avoided. · The microprocessor in the indoor unit should not be too close to r-f sources. After determining the pipe hole position on the installation plate ( ð ) drill the pipe hole (Ø65 mm) at a slight downward slant to the outdoor side. Remote controller · Should be placed where there are no obstacles, such as curtains, that may block the signal. · Do not install the remote controller in a place exposed to direct sunlight or close to a heating source, such as a stove. · Keep the remote controller at least 1 m away from the nearest TV set or stereo equipment. (This is necessary to prevent image disturbances or noise interference. ) · The location of the remote controller should be determined as shown below. NOTE : · When drilling into a wall that contains a metal lath, wire lath or metal plate, be sure to use a pipe hole brim ring sold separately. Mounting the installation plate Anchor bolt holes Indoor unit (Side view) (Top view) Indoor unit 25 mm 91 mm Pipe hole Reception range Remote controller Reception range Remote controller Pipe hole Indoor unit 7 Mounting screw 1 Installation plate *: Axial distance Fig. 10-3-3 ­ 75 ­ When the installation plate is directly mounted on the wall 1. Securely fit the installation plate onto the wall by screws with the upper and lower catches, that hold the indoor unit, facing out. The supply voltage must be the same as the rated voltage of the air conditioner. [. . . ] 224 225 226 227 228 229 230 232 233 234 235 236 238 239 240 245 246 247 Part No. 43047673 43044803 43044804 43039324 43049728 43019904 43049770 43062256 43062247 43082293 4306S577 43083071 43003307 43070188 43079268 43080516 43080527 4308N732 Description Pipe, Inlet Evaporator (*2) Evaporator (*1) Guide, Drain Guide, Drain, Left Holder, Sensor Holder, Evaporator, Right Cover, Terminal Cover, Lead Plate, Installation Remote Controller Holder, Remote Comtroller Body Ass'y, Back Hose, Drain Cap, Drain Electrical Air Purifying Filter Generator Ass'y, HV Owner's Manual (*1) B16GKVP-E, M16GKCVP-E (*2) B10GKVP-E, B13GKVP-E, M10GKCVP-E, M13GKCVP-E ­ 123 ­ Indoor Unit (2) 402 407, 408, 409 403 404 406 410 401 405 The parts in the following parts list are conformed to RoHS. Therefore be sure to use the following parts for repairing and replacing. 4306A123 43062263 43050425 43050426 4306S728 43051346 Description Terminal Block, 2P Cover, E-Parts Sensor, TC (F6) Sensor, TA P Board Ass'y, WRS-LED . C. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA AS200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA AS200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.