User manual TJERNLUND WHKE MILLIVOLT INTERLOCK KIT (COMPATIBLE WITH UC1 CONTROL) 8504108 REV 0802

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND WHKE MILLIVOLT INTERLOCK KIT (COMPATIBLE WITH UC1 CONTROL) 8504108 REV 0802. We hope that this TJERNLUND WHKE MILLIVOLT INTERLOCK KIT (COMPATIBLE WITH UC1 CONTROL) 8504108 REV 0802 user guide will be useful to you.


TJERNLUND WHKE MILLIVOLT INTERLOCK KIT (COMPATIBLE WITH UC1 CONTROL) 8504108 REV 0802 : Download the complete user guide (157 Ko)

Manual abstract: user guide TJERNLUND WHKE MILLIVOLT INTERLOCK KIT (COMPATIBLE WITH UC1 CONTROL) 8504108 REV 0802

Detailed instructions for use are in the User's Guide.

[. . . ] Using cable routing tabs from wire routing packet, attach Linear Limit control cable to appliance maintaining a safe distance from hot surfaces, e. g. appliance vent pipe and hot water pipes. LINEAR LIMIT SPILL SWITCH 950-0470 (JA1) THERMOCOUPLE JUNCTION ADAPTER GAS PRESSURE SWITCH INSTALLATION The gas pressure switch is mounted on the casing of the water heater adjacent to the heater's thermostat/gas control valve. It should be mounted close enough so that the supplied 1/4" tubing will reach from the gas pressure switch fitting to the thermostat/gas valve pressure tap port. The screws do not require the use of a drill and their 1/2" length assures that the inner tank will not be penetrated. [. . . ] SPILL SWITCH MUST BE INTERLOCKED WITH HEATING EQUIPMENT AS SHOWN. 30 MILLIVOLT WATER HEATERS REQUIRE USE OF THE 950-0470 THERMOCOUPLE JUNCTION ADAPTER. ON 750 MILLIVOLT (POWER PILE) WATER HEATERS WIRE LINEAR LIMIT SPILL SWITCH IN SERIES WITH HIGH LIMIT (ECO) OF WATER HEATER. LINEAR LIMIT SPILL SWITCH, 950-0470 JUNCTION ADAPTER AND GAS PRESSURE SWITCH ARE INCLUDED WITH WHKE KIT. CONNECTIONS WITH UC1, MAC1E OR MAC4E Each millivolt appliance interlocked with the UC1, MAC1E or MAC4E must have its own WHKE kit installed. The WHKE Gas Pressure Switch actuates the Venter through the A - B Dry contacts. The Linear Limit switch disables the heater in the event of a venting malfunction. IMPORTANT: Each millivolt appliance interlocked with the UC1, MAC1E or MAC4E must have its own Linear Limit spill switch. Wire WHKE Gas Pressure Switch across A and B terminals on UC1, MAC1E or MAC4E. Wire WHKE Linear Limit in series with thermocouple junction adapter or high limit ECO of heater. Make sure RED voltage jumper on UC1, MAC1E or MAC4E is in the DRY position. If not previously completed, connect 115 VAC supply voltage to L & N terminals on UC1. If not previously completed, connect ground from UC1 whip to Venter ground. Connect Blue and Yellow leads from UC1 whip to Venter Fan Prover switch. If using a Draft Inducer and only venting millivolt appliances the PS1505 Fan Proving Switch is not necessary, see below for further information. DRAFT INDUCERS WITH ONLY MILLIVOLT APPLIANCES (PS1505 FAN PROVER NOT REQUIRED) When venting only millivolt gas control(s) with a draft inducer, the PS1505 fan prover is not necessary. It will, however, be necessary to "jumper" the P1 and P2 terminals on the UC1 Universal Control. Remove the call jumper across J1 and J2 and place it across P1 and P2 on the UC1. Deactivate the Prover Status Check circuit by pushing the #9 dip switch up, or to the "deactivated" position in the UC1 Universal Control. See "Prover Status Check Dip Switch Settings" in the Venter or UC1 instruction manual. The P1 & P2 proving switch circuit of the UC1 cannot control the burner operation of a millivolt gas control. When using a WHKE millivolt interlock kit, the appliance safety shutdown is accomplished by the Linear Limit spill switch which detects flue gas spillage. WARNING: The P1 & P2 proving switch circuit must only be jumpered when venting strictly millivolt appliances where the safety is provided by the Linear Limit. HS-SERIES POWER VENTERS WITH ONLY MILLIVOLT APPLIANCES (FAN PROVING SWITCH PROVIDED) When venting only millivolt gas control(s) with an HS-Series power venter connect Fan Prover leads as outlined above in step 5. [. . . ] It is not designed to, and cannot replace regular chimney inspection, appliance servicing and combustion testing. DO NOT USE THE LINEAR LIMIT AS A SUBSTITUTE FOR PROFESSIONAL APPLIANCE MAINTENANCE. 1. If appliance is installed in utility room or closet, close the entrance door to this room. Turn on clothes dryer and all exhaust fans such as range hoods, bathroom exhausts and whole house fans to maximum speeds. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND WHKE MILLIVOLT INTERLOCK KIT (COMPATIBLE WITH UC1 CONTROL) 8504108 REV 0802




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND WHKE MILLIVOLT INTERLOCK KIT (COMPATIBLE WITH UC1 CONTROL) 8504108 REV 0802 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.