User manual TJERNLUND VSUB20SS DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND VSUB20SS. We hope that this TJERNLUND VSUB20SS user guide will be useful to you.


TJERNLUND VSUB20SS DATASHEET: Download the complete user guide (65 Ko)

Manual abstract: user guide TJERNLUND VSUB20SSDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Submitt al Dat a Sheet VSUB20SS Variable S peed Universal Job Name: Contractor: Arch. /Engr. : Description: The VSUB20SS Variable Speed Universal Blower is suitable for providing combustion air or sidewall or vertically venting heating appliances, dryers and ovens. [. . . ] Housing Construction: Constructed of 14-gauge, Type 316L stainless steel with continuous welds. The motor chassis slides away from the housing on polyethylene guides for easy motor and impeller access. Impeller: Backward inclined, Type 304 stainless steel, Class 1 impeller is both dynamically and statically balanced with permanently attached balancing weights. Motor: Three phase, 3 HP, 208-230/460 VAC, TEFC, EPACT High Efficiency Rated, arctic-duty, thermal overload protected, permanently lubricated and sealed ball bearing. Standard Equipment: · 4" x 4" weatherproof junction box with 4' conduit · Square to round vent pipe adapter · PSA-1 Fan Proving Switch · FFP-1 Freeze and Fire Protection Limit (FFP-1 For combustion air applications only!) · Condensate drain kit Optional Controls: · CPC-3 Constant Pressure Controller · IPS-1 Indoor Pressure Sensor decorative cover, fittings · TD-2 Pressure Transducer (+0. 15" to -0. 60" w. c. ) For draft or "Sealed" (ducted sealed combustion air) sensing · TD-3 Pressure Transducer (+0. 10" to -0. 10" w. c. ) For "Open" (room pressure) combustion air sensing · VFD-Series Variable Frequency Drives Temperature Rating: U. S. and Canada 575°F / 300°C Equipment Rep: Prepared By: Date: Listings: ETL # 56826 UL 378 - Draft Equipment / Variable Speed UL 705 - Power Ventilators CSA-CAN3-B255-M81* *Not Listed for use on condensing equipment in Canada. Warranty: 2 year mechanical Model VSUB20SS Power Amps Voltage Weight hp A VAC 208-230 Volt 3 8. 8 - 8. 2 3x208-230 460 Volt 3 4. 1 3x460 370 Lbs. [. . . ] · 1601 Ninth Street · White Bear Lake, MN 55110 · (651) 426-2993 · (800) 255-4208 · FAX (651) 426-9547 · www. tjernlund. com P/N 8513040 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND VSUB20SS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND VSUB20SS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.