User manual TJERNLUND SS1C SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504040 REV 4 0595

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND SS1C SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504040 REV 4 0595. We hope that this TJERNLUND SS1C SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504040 REV 4 0595 user guide will be useful to you.


TJERNLUND SS1C SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504040 REV 4 0595 : Download the complete user guide (373 Ko)

Manual abstract: user guide TJERNLUND SS1C SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504040 REV 4 0595

Detailed instructions for use are in the User's Guide.

[. . . ] 4 5/95 TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com MODEL SS1C INSTALLATION INSTRUCTIONS !Recognize this symbol as an indication of important Safety Information! OWNER INSTRUCTIONS, DO NOT DESTROY NOTE: FLUE GAS TEMPERATURES MUST NOT EXCEED 301 oC 575oF AT VENT SYSTEM INLET. THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, OR PERSONAL INJURY OR PROPERTY DAMAGE. [. . . ] high limit, low limit and all other safety controls the appliance is equipped with) and continues through the R8184G primary control. Current will then flow out of the orange of the R8184G to the SideShot Relay/Timer and safety circuit. When the Relay/Timer receives current, the SideShot motor is energized. After draft is established within the SideShot, the Fan Proving Switch closes completing the circuit to the burner motor. It is important to remember that the electrical interlock of the SideShot is always done at the final signal which would normally start the burner motor. All thermostats, zones, limits and circulators are to be wired as normally done on a chimney vented appliance. If your appliance is not equipped with an R8184G as outlined in these diagrams, locate the wire from the primary control which is connected to the black burner motor wire and follow the steps outlined on Page 11. SIDESHOT FACTORY WIRING TYPICAL OIL FIELD WIRING 10 SIDESHOT CONNECTED TO AN R8184G WITH THE APPLIANCE BURNER MOTOR LESS THAN 6. 2 AMPS @ 120 VAC LADDER DIAGRAM CONNECTION DIAGRAM NOTES: The SideShot is always interlocked with the primary control of the appliance. Wire all other furnace/boiler controls as normally done when conventional venting before continuing. Disconnect power from the appliance before attempting to interlock the SideShot. Separate the black burner motor wire from the Orange wire of the R8184G. NOTE: Do not separate ignition transformer wire or the optional oil valve wire from the Orange. Connect the Black burner motor wire to terminal Y on the SideShot terminal strip. Connect the Orange wire of the R8184G to the O terminal on the SideShot terminal strip. Connect the White wire of the R8184G to the R terminal of the SideShot terminal strip. NOTE: The White wire from the R8184G will also be connected to L2 or B2 as normally done when conventional venting. Connect the Ground to grounding screw in SideShot junction box. STANDARD HONEYWELL ST9103 WIRING 11 HONEYWELL ST9103 WIRING WITH BURNER MOTOR POST PURGE SIDESHOT CONNECTED TO A RIELLO BURNER SIDESHOT CONNECTED TO A PHELON CONTROL 12 DRAFT ADJUSTMENT OIL The SideShot Vent system will properly vent a wide range of BTU/hr. To compensate for different burner capacities, vent connector lengths and wind conditions it features a draft adjustment located on the outside of the Vent Hood. In general, positioning the draft adjustment inward will cause the SideShot to operate at lowest capacity. Positioning the draft adjustment outward will cause the SideShot to operate at highest capacity. IMPORTANT: The following paragraph describes the initial draft adjustment. It may be necessary to make a slight readjustment to compensate for various conditions: wind, vent connector resistance, negative building pressure and multiple appliances. [. . . ] Wheels "fused" to shaft may require penetrating oil and/or a wheel puller to facilitate removal. MOTOR OILING (DIAGRAM N) The SideShot motor is permanently lubricated and requires no oiling. 18 LIMITED PARTS AND WARRANTY CLAIM PROCEDURE Tjernlund Products, Inc. warrants the components of the SideShot for two years from date of installation. This warranty does not cover normal maintenance, transportation or installation charges for replacement parts or any other service calls or repairs. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND SS1C SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504040 REV 4 0595




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND SS1C SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504040 REV 4 0595 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.