User manual TJERNLUND SS1 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504041 REV A 1199

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND SS1 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504041 REV A 1199. We hope that this TJERNLUND SS1 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504041 REV A 1199 user guide will be useful to you.


TJERNLUND SS1 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504041 REV A 1199 : Download the complete user guide (497 Ko)

Manual abstract: user guide TJERNLUND SS1 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504041 REV A 1199

Detailed instructions for use are in the User's Guide.

[. . . ] A 11/99 TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com T0890551100 MODEL SS1 INSTALLATION INSTRUCTIONS !Recognize this symbol as an indication of important Safety Information! OWNER INSTRUCTIONS, DO NOT DESTROY NOTE: FLUE GAS TEMPERATURES MUST NOT EXCEED 650o F AT VENT SYSTEM INLET. THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, OR PERSONAL INJURY OR PROPERTY DAMAGE. [. . . ] The electrical contact ratings for the diaphragm Fan Proving Switch and High Limit are as follows: FAN PROVING SWITCH 6. 2 Amps (full load) at 120 VAC 36 Amps (locked rotor) at 120 VAC HIGH LIMIT 10 Amps (full load) at 120 VAC 60 Amps (locked rotor) at 120 VAC The Fan Proving Switch and High Limit are not suitable for loads which exceed the above limits. SEQUENCE OF OPERATION WITH THE SIDESHOT INSTALLED ON 24 VOLT CONTROLLED GAS APPLIANCES: As the thermostat/aquastat senses a need for heat, the internal switch of the thermostat/aquastat will close. The switch closure sends current through the internal controls of appliance (e. g. high limit, low limit and all other safety controls the appliance is equipped with) and continues to the SideShot Relay/Timer and safety circuit. When the Relay/Timer receives current, the SideShot motor is energized. After draft is established within the SideShot, the Fan Proving Switch closes completing the circuit to the 24 volt gas valve. It is important to remember that the electrical interlock of the SideShot is always done at the final signal which would normally control the gas valve. All thermostats, zones, limits and circulators are to be wired as normally done on a chimney vented appliance. If your appliance gas valve is not labeled TH, TR as outlined in these diagrams, determine the "HOT" and "COM" terminals on the gas valve and follow the steps outlined on the bottom of Page 15. SIDESHOT FACTORY WIRING 14 SIDESHOT CONNECTED TO A 24V FURNACE OR BOILER WITH INTERMITTENT IGNITION LADDER DIAGRAM CONNECTION DIAGRAM SIDESHOT CONNECTED TO A 24V BOILER WITH A STANDING PILOT LADDER DIAGRAM CONNECTION DIAGRAM NOTES: The SideShot is always interlocked with the gas valve of the appliance. Wire all other furnace/boiler controls as normally done when conventional venting before continuing. Disconnect power from the appliance before attempting to interlock the SideShot. Remove the wire that is factory installed to the TH (HOT) terminal of the 24V gas valve. Connect the wire removed from the TH(HOT) terminal in step 1 to terminal O of the SideShot terminal strip. Connect terminal Y of the SideShot terminal strip to the TH (HOT) terminal of the 24V gas valve. Connect terminal R of the SideShot terminal strip to the TR(COM) terminal of the 24V gas valve. NOTE: Do not remove the factory installed wire from the TR(COM) terminal. Connect the Ground to grounding screw in SideShot electrical box. DRAFT ADJUSTMENT OIL The SideShot Vent system will properly vent a wide range of BTU/hr. To compensate for different burner capacities, vent connector lengths and wind conditions it features a draft adjustment located on the outside of the Vent Hood. In general, positioning the draft adjustment inward will cause the SideShot to operate at lowest capacity. Positioning the draft adjustment outward will cause the SideShot to operate at highest capacity. IMPORTANT: The following paragraph describes the initial draft adjustment. It may be necessary to make a slight readjustment to compensate for various conditions: wind, vent connector resistance, negative building pressure and multiple appliances. [. . . ] Wheels "fused" to shaft may require penetrating oil and/or a wheel puller to facilitate removal. MOTOR OILING The SideShot motor is permanently lubricated and requires no oiling. 21 LIMITED PARTS WARRANTY AND CLAIM PROCEDURE Tjernlund Products, Inc. warrants the components of the SideShot for two years from date of installation. This warranty does not cover normal maintenance, transportation or installation charges for replacement parts or any other service calls or repairs. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND SS1 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504041 REV A 1199




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND SS1 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504041 REV A 1199 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.