User manual TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCERS 8506003 REV B 0803

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCERS 8506003 REV B 0803. We hope that this TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCERS 8506003 REV B 0803 user guide will be useful to you.


TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCERS 8506003 REV B 0803 : Download the complete user guide (198 Ko)

Manual abstract: user guide TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCERS 8506003 REV B 0803

Detailed instructions for use are in the User's Guide.

[. . . ] TJERNLUND COMMERCIAL IN-FORCER DESCRIPTION TM MODELS PAI-3/4/5/6/7 SPECS. The IN-FORCER commercial combustion air intake systems are designed and Listed for use with atmospheric or induced combustion gas and oil heating equipment. The IN-FORCER functions as the source of combustion air, eliminating the need for louvered openings. [. . . ] If wiring the PAI-7 motor for 208-230 VAC in conjunction with the UC1, a 115 VAC coil, DPST motor contactor rated for 1 H. P. If the UC1 control is not used, a 24 or 115 VAC relay (based on appliance control circuit voltage) suitable to handle the PAI motor load may be used to activate the IN-FORCER motor. IN-FORCER can be directly wired into 115 VAC appliance control circuits as long as contacts of the circuit can handle the additional load of IN-FORCER motor. Multiple Appliance Interlocks: Requires use of UC1 Universal Control and MAC1E for two appliances. If wiring the PAI-7 motor for 208-230 VAC in conjunction with the UC1, a 115 VAC coil, DPST motor contactor rated for 1 H. P. Fan Proving Switch: If using the UC1 Universal Control, 5 VDC board supplied power is switched through the Fan Prover. If not using the UC1, do not exceed 3 FLA or 1/10 HP through proving switch contacts or an isolation relay will have to be added. High Limit: Manual reset N/C contacts, open at 160° + 8° F, 14 FLA @120 VAC. The high limit switch will deactivate the IN-FORCER if temperature adjacent to high limit reaches the set point. Reset button is located on inside of cabinet on electrical box side of IN-FORCER. INTAKE HOOD DIMENSIONS IN-FORCER COMBUSTION AIR INTAKE DIMENSIONS COMMERCIAL IN-FORCER PERFORMANCE CURVES SAMPLE SPECIFICATION Furnish _____ fan powered combustion air intake system(s). System shall incorporate fan proving switch safety interlock and high ambient temperature cut-off in the event of mechanical room fire. Combustion air intake system shall include wall / roof mountable intake hood. Intake hood should be made of corrosion proof 5052 aluminum. IN-FORCER WEIGHT (LBS) ACTUAL SHIP COMPONENT WEIGHT WEIGHT PAI-3 Combustion Air Intake System* 20 48 PAI-4 Combustion Air Intake System 26 32 PAI-5 Combustion Air Intake System 60 60 PAI-6 Combustion Air Intake System 61 61 PAI-7 Combustion Air Intake System 95 95 PAI-3 Intake Hood* 12 * PAI-4 Intake Hood 15 27 PAI-5 Intake Hood 16 50 PAI-6 Intake Hood 16 50 PAI-7 Intake Hood 20 70 *The PAI-3 Intake System & Hood ship in the same box. Ship weights are based on UPS oversized rates. P/N 8506003 REV B 08/03 IN-FORCER APPLICATION AND SELECTION TABLE Verify that the total BTU/hr input of the heating appliance(s) falls within the range specified below. [. . . ] If interlocking IN-FORCER with different types of equipment consult Tjernlund Technical Customer Service @ 1-800-255-4208 for further information. Tjernlund Products, Inc. · White Bear Lk, MN 55110 · www. tjernlund. com · (651) 426-2993 · (800) 255-4208 · FAX (651) 426-9547 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCERS 8506003 REV B 0803




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCERS 8506003 REV B 0803 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.