User manual TJERNLUND HS115-3,4,5 (DISCONTINUED) 8505010 REV 0800

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND HS115-3,4,5 (DISCONTINUED) 8505010 REV 0800. We hope that this TJERNLUND HS115-3,4,5 (DISCONTINUED) 8505010 REV 0800 user guide will be useful to you.


TJERNLUND HS115-3,4,5 (DISCONTINUED) 8505010 REV 0800 : Download the complete user guide (574 Ko)

Manual abstract: user guide TJERNLUND HS115-3,4,5 (DISCONTINUED) 8505010 REV 0800

Detailed instructions for use are in the User's Guide.

[. . . ] TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM WARNING: The BLACK & WHITE Power Venter motor wires shown the diagram below are applicable only for the HS115-3. For models HS115-4 & HS115-5 use BLACK and WHITE wires from electrical box wip and connect to proper terminals on motor. Upon first startup, as viewed from opposite end of shaft, verify HS115-4 & HS115-5 motors rotate clockwise. HS115-3, 4, 5 Motor and Fan Prover specifications are the same as the equivalent HS-3, 4, 5 model. [. . . ] If possible, locate the Vent Hood on a wall that does not face the direction of prevailing winds. This will diminish the possibility of appliance interruption during periods of extreme winds. If possible, locate the Vent Hood no closer than 3 feet from an inside corner of an L-shaped structure. CODE REQUIREMENTS Terminate the vent system so that proper minimum clearances are maintained as cited in the latest edition of the National Fuel Gas Code (NFPA # 54) and the latest edition of Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances, (NFPA #211), or as follows: · · · · · · Not be less than 7 feet above grade when located adjacent to public walk ways. At least 4 feet below, 4 feet horizontally from or 1 foot above any door, window or gravity air inlet into any building. So that the flue gases are not directed so as to jeopardize people, overheat combustible structures or enter buildings, and Not less than 2 feet from an adjacent building. 3 POWER VENTER MOUNTING The installer must supply plumber's strap or 1/4" threaded rod with nuts and washers for mounting. The Power Venter may be mounted in any position as long as the shaft of the motor remains horizontal. The Power Venter housing is single wall, 6 inches must be maintained from all combustible materials. It is recommended that the Power Venter be mounted as close as possible to the point of termination. HS-3 HS-4, HS-5 VENT PIPE INSTALLATION If Installing the Power Venter on an appliance not equipped with a draft hood or draft diverter (e. g. Power Burners, Induced Draft), a barometric draft control must be added. The barometric draft control must be the same size as the flue outlet and installed as close as possible to the appliance. After the draft hood, draft diverter or barometric draft control, a tapered reducer should be installed to reduce the flue to the size shown in the selection table on page 2 of these instructions. After the tapered reducer, install the appropriate type of vent pipe to the inlet of the Power Venter. The Power Venter inlet and outlet are designed to accept single wall vent pipe. If using vent pipe other than single wall, the installer must supply adapters to connect to the Power Venter. ELECTRICAL SPECIFICATIONS 5 MODEL HS-3, HS-4, HS-5 WIRING WITH SINGLE APPLIANCE The HS-3, HS-4, and HS-5 Power Venters are equipped with 2 relays. One is used to activate the Power Venter while the other is used to isolate the Fan Proving Switch from the load of the appliance. The relays and Fan Proving Switch are factory wired for easy installation. The installer needs to complete 3 steps to wire the Power Venter as noted below: 1. Route the metal conduit from the electrical box to the Power Venter motor and connect the Black, White and Ground wires to the motor. Connect the Red, Blue and Orange wires in the electrical box to the appliance. NOTE: All models as viewed from the opposite end of the shaft should rotate clockwise. [. . . ] Model number of the Power Venter Name and address of installer and service agency Date of original installation and dates any service work was performed Details of the problem 10 LIMITED PARTS WARRANTY AND CLAIM PROCEDURE Tjernlund Products, Inc. warrants the components of its products for one year from date of installation. This warranty does not cover normal maintenance, transportation or installation charges for replacement parts or any other service calls or repairs. Products that are tampered with, damaged, or defective due to malfunctioning appliances are not covered under this warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND HS115-3,4,5 (DISCONTINUED) 8505010 REV 0800




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND HS115-3,4,5 (DISCONTINUED) 8505010 REV 0800 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.