User manual TJERNLUND 950-2061 PILOT SAVER KIT 8504028 REV 2 0995

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND 950-2061 PILOT SAVER KIT 8504028 REV 2 0995. We hope that this TJERNLUND 950-2061 PILOT SAVER KIT 8504028 REV 2 0995 user guide will be useful to you.


TJERNLUND 950-2061 PILOT SAVER KIT 8504028 REV 2 0995 : Download the complete user guide (34 Ko)

Manual abstract: user guide TJERNLUND 950-2061 PILOT SAVER KIT 8504028 REV 2 0995

Detailed instructions for use are in the User's Guide.

[. . . ] TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com PILOT SAVER (950-2061) INSTRUCTIONS NEW VP-2/3, WHK-2 INSTALLATION NOTES: 4 inches of STRAIGHT VERTICAL Burner line must be available between the gas valve (thermostat) and the burner assembly for proper installation of Pilot Saver kit. These instructions take the place of the Gas Solenoid Valve mounting instructions in VP-2/3 and WHK-2 manual. [. . . ] NOTE: Before tightening compression fitting on burner line, make sure male end which screws into gas valve is orientated properly and is between compression fitting and flared end of burner tubing. Insert burner line from burner assembly into compression side of Compression Fitting. Reconnect burner line, pilot line, and thermocouple to gas valve (thermostat). All gas piping shall be tested and inspected in accordance with NFPA 54, ANSI Z223. 1, part 4. This modification is acceptable per the American Gas Association (AGA) Report No: 916-1A. 2, 9/95 PILOT SAVER (950-2061) INSTRUCTIONS EXISTING VP-2/3, WHK-2 INSTALLATION NOTES: 4 inches of STRAIGHT VERTICAL Burner line must be available between the gas valve (thermostat) and the burner assembly for proper installation of Pilot Saver kit. These instructions take the place of the Gas Solenoid Valve mounting instructions in VP-2/3 and WHK-2 manual. The 3/8" to 1/2" adapter fittings in Safety Controls Kit are not required. TOOLS REQUIRED Pipe Cutter Adjustable Wrench Pipe Thread Sealant IMPORTANT: Shut off gas supply before attempting the following procedure. Remove the burner line, pilot line and thermocouple from gas valve (thermostat). Disconnect burner assembly from water heater with burner line still attached. Remove 3 inches of vertical burner line between flared end and burner assembly. [. . . ] This modification is acceptable per the American Gas Association (AGA) Report No: 916-1A. PREVIOUS INSTALLATION WITHOUT PILOT SAVER INSTALLATION AFTER PILOT SAVER INSTALLED Step 9. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND 950-2061 PILOT SAVER KIT 8504028 REV 2 0995




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND 950-2061 PILOT SAVER KIT 8504028 REV 2 0995 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.