User manual THETA DIGITAL GENERATION VIII RS232 PROTO

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THETA DIGITAL GENERATION VIII RS232 PROTO. We hope that this THETA DIGITAL GENERATION VIII RS232 PROTO user guide will be useful to you.


THETA DIGITAL GENERATION VIII RS232 PROTO : Download the complete user guide (247 Ko)

Manual abstract: user guide THETA DIGITAL GENERATION VIII RS232 PROTO

Detailed instructions for use are in the User's Guide.

[. . . ] THETA DIGITAL C O R P O R A T I O N Generation VIII RS232 Control Protocol V 1. 02 Digital Done Right TM RS232 Hardware Connections These are the connector drawings only. [. . . ] or information on changing these settings. The parameters for RS232 communication will default to 8 bits, 1 stop bit and no parity. All commands will follow the format: <Header><Command Identifier><Argument 1><Argument 2><Argument 3> where: <Header> = <254><241> <Command identifier> = <byte> <Argument 1> = <byte> <Argument 2> = <byte> <Argument 3> = <byte> Each command will be able to access the system configuration directly, eliminating the need to press any button on the Generation VIII's front panel. Examples: 1) To put the Generation VIII into standby: Send 254, 241, 04, 14, 01, 00 (all values in decimal). Where 254 and 241 are the header, 04 = Command_Do Action, 14 = Action_Power Main, 01 = put unit into standby, and 00 = filler (4 characters required). 2) To change to Input # 2: Send 254, 241, 01, 04, 00, 02 Where 254 and 241 are the header, 01 = Command_Variable_Change, 04 = Variable_Input_Selected, 00 = filler (4 characters required), and 02 = Input 2. -OR254, 241, 04, 05, 02, 00 Where 254 and 241 are the header, 04 = Command_Do Action, 05 = Select Input, 02 = Input 2, and 00 = filler (4 characters required. 3) To increment the Master Volume: Send 254, 241, 04, 20, 00, 00 Where 254 and 241 are the header, 04 = Command_Do Action, 20 = Action_Variable Specified Increment, 00 = Variable_Master Volume, and 00 = filler (4 characters required) 3 Please note: All values below are in decimal. [. . . ] 40 Variable 33 Simulate Keypress List Key Value 1-5 1-5 Mute 8 Setup 11 Display 13 Standby 14 Level up 15 Level down 16 Level Left 19 Level Right 20 Phase 21 Discrete Off 25 Discrete On 26 Value 1-5 1-8 0-86 0-1 0-1 0-7 0=standby, 1=not in standby 0=not locked, 1=locked 0=32K, 1=44K, 2=48K, 4=88K, 5=96K, 6=176K, 7=192K 6 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THETA DIGITAL GENERATION VIII RS232 PROTO




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THETA DIGITAL GENERATION VIII RS232 PROTO will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.