User manual THERMADOR LI164A

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THERMADOR LI164A. We hope that this THERMADOR LI164A user guide will be useful to you.


THERMADOR LI164A : Download the complete user guide (752 Ko)

Manual abstract: user guide THERMADOR LI164A

Detailed instructions for use are in the User's Guide.

[. . . ] Each successive press of the button increases the fan speed until high where the fan cycles back to the low speed. 1 ­ Low 2 ­ Medium 3 ­ High Delay Shut Off : Press to turn fan on high for 15 minutes. If the blower is off when the delay button is pressed, the ventilator will turn on to the high speed setting for 15 minutes. [. . . ] Filter: After 40 hours of operation, the clean filter reminder LED above this button will illuminate indicating that the filters need to be cleaned. After cleaning, press this button for 3 seconds to reset the 40-hour period and turn the LED off. Heat Lamp: The buttons marked L and R independently control the left and right infrared heating lamps, turning the lights on or off. Heat Sensor: Your hood is equipped with a heat sensor that will turn the blower to Low speed if excessive heat occurs above the cooking surfaces. If the blower is already on any speed selection, no speed change will occur. When the temperature level on the hood drops to normal, the blower will return to its original setting. Overtemperature : The high temperature sensor protects the hood from high temperatures which may damage components. The control is set to activate at 161º F (72º C) and reset at 140ºF (60º C). When activated, the ventilator will turn on low and the corresponding LED will blink, indicating an over temperature condition. While the high temperature sensor is activated, the blower speed can be changed or turned off. When the control sensor reaches 140ºF (60º C), a reset will occur. During reset, the control will revert back to the operational state prior to the high temperature condition. High Temperature Fault Condition: The circuit is equipped with an alarm indicating that the heat sensor protection is not working, due to a damaged sensor. In the case of this extreme condition, the three speed indicator LEDs will start blinking. All the controls will be operational except for the speed indicators. Page 3 HOOD OPERATING INSTRUCTIONS The blower should be turned on for a few minutes before cooking in order to establish air currents upward through the hood. Thus when heat, smoke, moisture, grease and cooking odors are produced, they will be carried outside instead of drifting into other rooms. Use the low speeds for normal use and the higher speeds for strong odors or fumes. Drafts across the range or cooktop will cause the escape of heat, smoke, moisture, grease and cooking odors from the hood. [. . . ] Replace Lights (HS and HST series hoods only) Using a flat edge from a screwdriver or equivalent tool pry loose the lens cover as shown in Figure 2. Remove the damaged light and replace with a new 12 Volt, 20 Watt (maximum) halogen light made for a G-4 base. THESE ARE AVAILABLE ON "HS" AND "HST" SERIES HOODS AS OPTIONAL ACCESSORY TO BE PURCHASED APART. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR LI164A




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR LI164A will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.