User manual THERMADOR 9000008294

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THERMADOR 9000008294. We hope that this THERMADOR 9000008294 user guide will be useful to you.


THERMADOR 9000008294 : Download the complete user guide (178 Ko)

Manual abstract: user guide THERMADOR 9000008294

Detailed instructions for use are in the User's Guide.

[. . . ] VERIFY THAT THE ANTI-TIP DEVICE IS ENGAGED PER INSTALLATION IN­STRUCTIONS. (NOTE: ANTI-TIP DEVICE IS REQUIRED ON ALL 30" AND 36" RANGES) Note: This grill is NOT designed for installation in manufactured (mobile) homes or for installation in Recreational Park Trailers. Contents SECTION 1: Safety Information . . . Inside Cover Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 SECTION 5: Electrical Requirements and Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 SECTION 6: Unpacking, Moving and Placing the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Hoods that incorporate grease filters of mesh construction should not be used. Testing has shown that mesh filters can collect and hold enough grease to become a fire hazard. Due to the high heat capacity of this unit, and the smoke generated during grilling of foods, particular attention should be paid to the hood and ductwork installation to insure it meets local building codes. Due to the high volume of ventilation air required, a source of outside replacement (make-up) air is recommended. Table 1 indicates the Thermador hoods, by model number, that are recommended for use with the indoor grill. For wall installations, the minimum hood width is 36" (915 mm) [3" (77 mm) overhang per side]. Where space permits, a wider hood may be desirable for improved ventilation performance. For best smoke capture, the lower edge of the hood Installation Type Wall Table 1 Hood PH36ZS1 PH42ZS PH48ZS PH54ZS Blower VTNl000Q Notes: 1 For wall installation where adequate space is available, the installer or user may elect to use a hood that is wider than the grill cooking surface. This may be particularly beneficial for those cases, such as a long duct run or heavy usage of the grill, in which improved capturing of the cooking exhaust is desired. should be installed a minimum of 30" (762 mm) to a maximum of 36" (915 mm) above the grill cooking surface. NOTE: Ventilation hoods and blowers are designed for use with single-wall ducting. Before starting installation, consult local building codes and agencies to insure that the installation will meet local requirements. Section 5: Electrical Requirenments and Grounding Instructions The Thermador Professional® Indoor Grill uses an electronic ignition system that requires a 120 VAC, 10A, 60 Hz power supply. A properly grounded and polarized duplex outlet must be provided adjacent to the lower left rear corner of the unit. See Figure 5. CAUTION Installation of electrical supply circuit should be done by a qualified electrician in accordance with local codes and ordinances. In the absence of local codes or ordinances, the supply should be installed in accordance with the National Electric Code ANSI/NFPA70-current issue. Figure 5. WARNING Electrical Grounding Instructions This indoor cooking gas appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. 5 Three-Prong Plug and Receptacle Section 6: Unpacking, Moving and Placing the Unit LOCATING YOUR PROFESSIONAL® GRILL Remove all packing materials and temporary labels from the grill. 1. Check that you have all the items listed for your model, as shown in the chart below. The conversion should be done by a qualified technician or your gas supplier. Make sure that the unit is disconnected from the gas and electrical supplies. From inside control panel area, locate the brass elbows that the orifices are attached to. Use a wrench on the flats of these elbows to keep them from turning during orifice removal and installation. Remove the main burner orifices and replace with the LP orifices supplied (marked 54). Orifice must extend a minimum of 1/8" into main burner air shutter with burner installed. [. . . ] u Manual gas shut off valve is installed in an accessible location (with unit installed in enclosure for built-in installations). u Gas supply pressure does not exceed 14" W. C. Specifications are for planning purposes only. Refer to installation instructions and consult your countertop supplier prior to making counter opening. Consult with a heating and ventilating engineer for your specific ventilation requirements. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 9000008294




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 9000008294 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.