[. . . ] UNIVERSAL COOK'N'VENT ® INSTALLATION INSTRUCTIONS MODELS: UCV30 · UCV36 · UCV45 Rating: 120 Volt, 60 Hz. , 10. 0 Amps. For Integral Blower Installations: · Requires Integral Blower: Model # VTN600CVA · Requires Round Duct Size (6" Diam. ) · Requires Dedicated Branch Circuit Power Supply · 120 Volt AC· min. · See Steps 3 and 5 for electrical receptacle and duct outlet location For Remote Blower Installations: · Requires Remote Blower: Model # VTR1000Q or VTR600R · Requires Duct Transition: Model # CVT314 (for 3-1/4" x 14" duct) or Model # CVT7 (for 7" Diam. Round) · Requires 4 wires and 1 ground wire connecting blower and vent · Requires Dedicated Branch Circuit Power Supply · 120 Volt · 15 Amps. , 3 prong receptacle · 60 Hz. , AC. For CVT314: · Recommend 3-1/4" x 14" to 10" diam. [. . . ] · Use sheet metal screws as required to support the duct weight, and seal all joints with duct tape. · Be certain that the duct work does not interfere with floor joists or wall studs. · Thermal breaks, such as a short section of nonmetallic duct, should be used in areas of extreme cold. Laundry type wall caps should never be used. Keep duct runs as short and straight as possible. · Duct fittings (elbows and transitions) reduce air flow efficiency. · Back to back elbows and "S" turns significantly reduces air flow and are not recommended. · A short straight length of duct at the inlet of the remote blower gives the best delivery. · Transition to round duct as close to the Cook`n'Vent® as possible. 6" round duct · The use of flexible metal round duct should only be used when no other duct fitting exists. · Where local codes permit, plastic pipe (PVCschedule 40 pipe or ABS pipe 7" or 8" diameter) can be used in areas of high ground moisture and in slab floors to eliminate future rusting. STEP 2 PREPARE COUNTERTOP CUTOUT For installation of the Cook'n'Vent® with a Thermador cooktop, refer to Part A and Figure 7. For installation with another brand of cooktop, refer to Part B and Figure 8. For all installations, verify cutouts will clear the inside of the front countertop support rail. The front and rear cutouts must be straight and parallel to the front edge of countertop and the rear backsplash or wall. Assure that the side cutouts are square to the front and rear cutouts. All illustrations and dimensions are based upon standard 24" deep by 36" high American style base cabinets with 25" countertops. When installing laminated or solid surface countertops such as SurellTM and Corian®, be sure to follow the countertop manufacturer's instructions regarding minimum corner radii, reinforcement of corners, etc. For overhead cabinet and cooktop side clearances consult cooktop Installation Instructions. A. INSTALLATION WITH A THERMADOR COOKTOP (FIGURE 7 AND TABLE 3) Provide an opening in the countertop as specified in Table 3. Make sure the distance from the front of the countertop to the front of the cutout is not less than dimension "SB. " Verify that the available flat countertop is greater than dimensions "OW" by "OD. " Make certain the backsplash thickness does not exceed dimension "BT". Page 7 TABLE 3 (in inches) UCV30/36/45 INSTALLATION DIMENSIONS WITH THERMADOR COOKTOPS Cooktop Model No. SB is specified in the installation instructions shipped with the cooktop. Backsplash thickness must not exceed BT as calculated below: BT = 24 7/8" - SB+CO - OD - 2-1/4 (Provides 1 /8" clearance between vent and backsplash. ) A negative value for BT means countertop is too small for the installation. Verify that the available flat countertop has a width greater than OW and a depth greater than OD. OW depends on the installation: UCV30: OW equals the greater of COW or 30". Cut countertop using dims: CD, CW and SB as defined in Figure 8. 3. 4. 5. If CCW is larger than the UCV cutout width then: CW = CCW See Figure 8 for UCV cutout widths and dimension definitions. Figure 8 INSTALLATION WITH OTHER COOKTOPS WHERE SPECIFIED (SEE PART B) 5 V4 UC V30 C V36 /2" -U 3-1 1/2" - UC 4 28- -1/2" 34 2-1/4" 1/8 " BT C OD D CW W O SB Page 9 STEP 3 PREPARE DUCT CUTOUTS IN CABINET A. [. . . ] To hook up electrical wiring, press down on terminal block tab with small flathead screwdriver and hook up wires into the terminal blocks (as per wiring diagram and color key). Make sure to connect blower wire and the J-Box ground wire with the wire nut provided. Connect ductwork to blower. Figure 10 UCV WIRING DIAGRAM COLOR KEY Red = Low Blue = Medium Black = High White = Neutral Green = Ground Figure 11 Note: Use spring type wire nuts supplied to connect wires per Fig. (Lost or missing wire nuts should only be replaced with: Spring type wire nuts, rated for a minimum of (2) #18ga wires and max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 5060004249




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 5060004249 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.