User manual THERMADOR 19-12-182H

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THERMADOR 19-12-182H. We hope that this THERMADOR 19-12-182H user guide will be useful to you.


THERMADOR 19-12-182H : Download the complete user guide (55 Ko)

Manual abstract: user guide THERMADOR 19-12-182H

Detailed instructions for use are in the User's Guide.

[. . . ] When the service disconnecting means cannot be locked, attach a tag to the service panel to indicate power has been switched off for maintenance. WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Installation work and electrical wirgineers (ASHRAE), and the local ing must be done by qualified code authorities. When cutting or drilling into wall or applicable codes & standards, inceiling, do not damage electrical cluding fire-rated construction. [. . . ] Position the curb on flat roofs so that the discharge (low) end points away from prevailing wind. FOR WIRING TO ALL APPROVED THERMADOR® PRODUCTS, USE INSTALLATION INSTRUCTIONS PROVIDED WITH THAT PRODUCT. ¦ 20-3/4" 28" ¦ ¦ 2" 5-1/2" Roof Transition ¦ Transition Figure 6 ­ Remote Blower Dimensions 9-3/8" 11-3/8" 5-7/8" C A Adjustable Elbow G D EF 28" H I Tape Joints B Dia. Duct Conduit 20-3/4" J TYPICAL INSTALLATION USING THERMADOR HOODS D 10-1/4 10-1/4 11-1/2 E 3-1/8 3-1/8 4-5/8 F 17-5/8 17-5/8 14-7/8 G 10-3/4 10-3/4 8-3/4 H 10 10 8 I 26-1/4 26-1/4 24 J 4 4 3-1/2 III. Use Thermador 4 position ventilator speed control model CTR3Q (purchased separately). wires (black, white and green) from the power supply at the electrical circuit panel to the wall box. Run electrical conduit per local code to conduit outlet in bottom of ventilator as shown in Fig. Use wire nuts to connect wires as shown in Figure 8. 2 21 21 21 21 21 ¦21 21 21 21 21 21 21 21 21 21 21 21 21 21 Outside Wall ¦ ¦ ¦ IV. FOR WIRING TO A WALL MOUNT INFINITE VENTILATOR SPEED CONTROL SWITCH MODEL VTR600R ONLY: 1. Use Thermador infinite speed control switch model #SSC1C (Purchase separately). connected per local codes. NOTE: There should be two (2) excess wires (blue and red) from the motor. These wires are not needed for wiring to this infinite ventilator speed control switch. These wires should be individually capped with wire nuts and pushed back inside the wiring compartment on the remote ventilator VTR600R. Fig. wires (black, white and green) from the power supply at the electrical circuit panel to the wall box. Run electrical conduit per local code to conduit outlet in the bottom of ventilator as shown in Figure 5. Connect other end of conduit to wall box with speed control switch as shown in Figure 9. Run three (3) #14 AWG wires in conduit between VTR600R and the infinite ventilator speed control switch. 9 wiring diagram. WARNING: Disconnect power before installing switch. Before turning power on, be sure that all controls are in the OFF position. 1/2" Thin Wall Conduit Ventilator Wall Switch Model CTR3Q or SSC1C (VTR600R Only) (Not Provided) Fig. [. . . ] For best performance duct runs should be as short and as straight as possible. Where turns are necessary, keep turning radius as large and as smooth as possible. Thermador reserves the right to change specifications or design without notice. Thermador is not responsible for products which are transported from the United States for use in Canada. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 19-12-182H




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 19-12-182H will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.