[. . . ] Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. Install this hood in accordance with all requirements specified by the manufacturer of your cooktop/range. To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet one way. Do not attempt to defeat this safety feature. WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: A. [. . . ] Holes 22" "B" 1/2" 4-1/2" "C" Rear Wall Hood Length Figure 1 TYPICAL INSTALLATION The hoods are designed for either vertical or horizontal discharge as shown in Figure A and B respectively. The recommended height from the countertop to the bottom of the hood is 30" to 36". These hoods are not recommended to be used over solid fuel fire barbecues. ¨ Figure 2 Hood Type H series HB series HT Height "B" 10" 10" 18" DIM. C 18" 13" 18" Optional Rear Discharge Note: It is important to select the ventilator to be used before cutting the duct opening on the cabinet or wall. PAGE 3 Round Duct Soffit Rough-in Plate Heat Lamp Transition Ventilator (VTN600Q) Filter Hood Back Splash (with Warming Shelf) Hood Heat Lamp Soffit Rough-in Plate Outside Wall Wall Cap Filter 30" to 36" 30" to 36" Back Splash (with Warming Shelf) Cooktop Cooktop Figure A ­ Vertical Discharge INSTALL THE ROUGH-IN PLATE: Note: Before installing the rough-in plate to the bottom of the cabinet or soffit, make sure that the cabinet or soffit is level. Detach the rough-in plate from the hood assembly by removing three shipping screws on the back and three shipping screws on the top of the hood assembly. Remove the proper knockout panels on the rough-in plate for the selected ventilator. The rough-in plate is reversible to allow either horizontal or vertical discharge for both knockout panels. Attach the rough-in plate to the cabinet or wall with the mounting screws (#10 x 1") provided. (Use wall anchors as necessary on drywalls. ) Figure B ­ Horizontal Discharge Longer Bracket (Provided with H/ HT Hoods) 7-1/2" 8" 12-3/4" Figure C H/HB/HT HOOD SERIES Hex Nut INSTALL THE INTEGRAL VENTILATOR MODEL VM410 (H and HT only): Note: For HB series hood the ventilator is shipped and pre mounted to the rough-in plate. Remove the blower mounting bracket and replace with a longer bracket provided with the H/HT hood. Insert one end of the blower mounting bracket into the ventilator mounting channel located on the rough-in plate, and slip the other end over the weld stud on the rough-in plate. D. PAGE 4 ¨ ¨ Transition Ventilator VM410 INSTALL THE INTEGRAL VENTILATOR MODEL VTN600Q: Insert one end of the blower mounting bracket into the ventilator mounting channel located in the rough-in plate, and slip other end of bracket into the weld stud on the rough-in plate and tighten it with the hex nut provided with the hood. D. INSTALL THE REMOTE VENTILATOR MODEL VR600, VTR600R OR VTR1000Q: For installing the remote ventilator on the roof or side wall, refer to the Installation Instructions provided with the ventilator. DUCTING CONNECTION: FOR INTEGRAL VENTILATOR MODEL VM410, 19-11-943 (HB Hoods): 1. Attach the transition (3-1/4" x 10") provided to the top of the rough-in plate, using the two shipping screws. Seal all joints between the rough-in plate and the transition with duct tape. Install 3-1/4" x 10" duct from the transition to the wall or roof (use roof exhaust outlet RJ310 or wall exhaust outlet WC310, purchased separately). Install 8" round duct from the HTR8 transition to the side wall (use wall cap Model # WC8, purchased separately). FOR REMOTE VENTILATOR MODEL VTR600R, VTR1000Q: 1. For the VTR600R, attach transition Model HTR8 (purchase separately) or for VTR1000Q attach transition Model HTR10 (purchase separately), to the top of the rough-in plate. Seal all joints between the rough-in plate and the transition with duct tape. Use 8-inch round duct for the VTR600R or10-inch round duct for the VTR1000Q. [. . . ] Remove the knockout and install the strain relief (conduit) connector on the rough-in plate hole. Run three wires black, white and green (#16 AWG) in 1/2" conduit from the remote ventilator to the hood junction box. INSTALL HOOD ASSEMBLY: 1. Install the hood assembly to the rough-in plate by aligning the weld studs on the rough-in plate with slotted holes on the back of the hood assembly. Using the hex nuts provided secure the hood assembly to the rough-in plate. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 19-11-930F




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 19-11-930F will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.