User manual THERMADOR 19-10-199M

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THERMADOR 19-10-199M. We hope that this THERMADOR 19-10-199M user guide will be useful to you.


THERMADOR 19-10-199M : Download the complete user guide (62 Ko)

Manual abstract: user guide THERMADOR 19-10-199M

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION INSTRUCTIONS VENTILATOR CUSTOM KIT MODEL VCK1 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these instructions for the Local Electrical Inspector's use. INSTALLER: Please leave these Installation Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. IMPORTANT SAFETY INSTRUCTIONS WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. [. . . ] Be sure the 3-1/4" x 10" knockout on the housing body is REMOVED before attaching the damper collar. Fig. 2 DUCTINGFORVCK300 (For ventilator motor mounted inside of ventilator housing) ¦ 3. * Damper Collar and two Ventilator motor support bolts and nuts are shipped with the VCK300. To adapt this VCK-1 unit for installation with the VR1000 a Transition #130810 and a 10" round duct must be used. For installation with the VR600 a Transition #1308-8 and an 8" round duct must be used. Before installing VCK-1 in hood or cabinet attach transition to top of VCK1 through holes with screws provided. IMPORTANT: Be sure the 8" x 13" knockout on the top of the housing body is removed before attaching the Transition. VCK1 with VCK300 (Integral Blower), VR600 or VR1000 (Remote Blower) these installations must meet all local code requirements. Unless otherwise required by compliance with local codes, recommended installation height from countertop to VCK1 mounting surface over counter level range, cooktop, 30" to 34", over indoor barbecue 34" to 48". Cut a 9-3/4" x 19" opening in the bottom of the cabinet or hood to allow for the ventilator body (see figures 2 and 3 for minimum clearance). Fig. 3 ¦ DUCTINGFORTHEVR600&VR1000 (Vertical Discharge only) ¦ 10" Diameter Duct for VR1000 8" Diameter Duct for VR600 (Duct NOT supplied) Transitions: For VR1000 - #1308-10 For VR600 - #1308-8 Transition Height 10-1/4" Minimum Clearance 1-3/8" Mounting Surface Recommended Depth 4-1/4" · ¦ ¦ 2. Fig. 5 Mounting Bolts are installed in rear position for Horzontial Discharge Mounting Bolts are installed in forward position Vertical Discharge ¦ 9-3/4" x 18-3/8" Cutout 3/4" required for Clearing Collar for Horizontal Discharge Front ¦ · ¦ Safety Warning: Turn off proper circuit at the service entrance and lockout panel before wiring this unit. VCK300 ONLY - Attach power supply leads (120 volts, 60 Hz. ) in accordance with the local codes through the end or top conduit knockout holes. Make electrical connections to wires inside of "J" box -- Black to black and white to white. 5. ¦ 10-1/2" ¦ Minimum Absolute 10-1/2" ¦ 321 321 321 321 321 321 321 321 321 321 321 321 321 321 21 3221 21 1 3221 1 21 21 21 21 21 21 21 21 21 21 21 VCK300 VR600&VR1000 Transitions: For VR1000 #1308-10 For VR600 #1308-8 VERTICAL Absolute Minimum HORZONTAL 4. VR600 and VR1000 ONLY - If VR600 or VR1000 is installed with VCK1 the plug or cap is to remain over receptacle. Secure VCK1 into position using four 3/4" long screws (provided), see figure 1 for mounting holes. Page 2 ¦ ¦ DUCTING FOR VR1000 & VR600 321 321 321 321 321 321 321 3214321 5 3214321 5 321 321 321 321 ¦ 321 321 321 321 321 321 321 321 321 321 321 321 321 321 321 21 21 21 21 21 21 212 1 3 2321 21 1 3 2121¦ 21 21 21 21 21 21 21 21 ¦ 21 21 21 21 ¦ 21 21 21 21 21 ¦ ¦ ¦ VERTICAL DISCHARGE *Damper Collar for 3-1/4" x 10" duct Minimum Clearance 1-3/8" Minimum 3" Length of 3-1/4" x 10" Minimum Clearance 3/4" *To Bottom of Damper Collar 1-1/4" } } ¦ ¦ HORIZONTAL DISCHARGE ¦ Recommended Depth 4-1/4" Minimum ¦ ¦ 21 21 21 21 ¦ 21 21 21 21 21 21 21 21 ¦ 3 2321 31 121 2121 32 321 321 321 321 321 321 321 6. Place chrome reflectors into position and secure with chrome flat head countersunk screw (provided). VCK300 ONLY - Install VCK300 power unit (packed separately) as shown in figure 5. [. . . ] Thermador reserves the right to change specifications or design without notice. Thermador is not responsible for products which are transported from the United States for use in Canada. Thermador, 5551 McFadden Avenue, Huntington Beach, CA 92649. 5551 McFadden Avenue, Huntington Beach, CA 92649 · 800/735-4328 ECO#12080 · 19-10-199M · © Thermador Corporation, 1995 · Litho in U. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 19-10-199M




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 19-10-199M will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.