User manual THERMADOR 15-12-596C

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THERMADOR 15-12-596C. We hope that this THERMADOR 15-12-596C user guide will be useful to you.


THERMADOR 15-12-596C : Download the complete user guide (985 Ko)

Manual abstract: user guide THERMADOR 15-12-596C

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION INSTRUCTIONS MANUAL PROFESSIONAL RANGES ALL-GAS MODELS ­ PRG304, PRG36 AND PRG48 DUAL-FUEL MODELS - PRDS304, PRDS36 AND PRDS48 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. INSTALLATION, ELECTRICAL CONNECTIONS, GAS CONNECTIONS, AND GROUNDING MUST COMPLY WITH ALL APPLICABLE CODES. IMPORTANT: Save these instructions for the Local Electrical Inspector's use. INSTALLER: Please leave these Installation Instructions with this unit for the owner. (14. 9mb) min. , 8 inch (20mb) nominal Propane Gas ­ 11 inch water column. [. . . ] STEP D: If you plan to mount the bracket to the rear wall, slide the bracket back until it is positioned against the rear wall. If you plan to mount the bracket to the floor, position the bracket such that the center line of the mounting holes in the horizontal bracket flanges are 7/16" in front of the rear edge of the range side panel when the range is in its final installed position. STEP E: With the bracket properly positioned, use the bracket as a template and mark the location of the selected mounting holes in either the rear wall l (4 holes) or the floor (2 holes) with a pencil. STEP G: Using the screws provided, securely fasten the bracket to the rear wall (4 screws) or floor (2 screws). Page 12 May Be Used On Either Left or Right Side (Right Shown) Maximum Up to 2" FIG. 12a PRG36 Wall Mount (0" Clearance) PLAN VIEW PRG304: 2-3/4" PRG36: 4-5/8" May Be Used On Either Left or Right Side (Right Shown) SIDE VIEW FIG. 12b PRG Wall Mount (Max 2" Clearance) PLAN VIEW PRG304: 2-3/4" PRG36: 4-5/8" SIDE VIEW STEP 4: INSTALLING ANTI-TIP DEVICE May Be Used On Either Left or Right Side (Right Shown) SIDE VIEW Leveling Leg STEP I: Carefully slide the range into position. FOR THE ANTI-TIP CHANNEL TO ENGAGE THE MOUNTING BRACKET, THE REAR EDGE OF THE RANGE SIDE PANEL MUST BE WITHIN 2" OF THE VERTICAL ENGAGES TO PREVENT TIPPING. MOUNTING FLANGE OF THE ANTI-TIP BRACKET, AND THE ADJUSTABLE MOUNTING CHANNEL MUST BE ATTACHED TO THE APPROPRIATE MOUNTING HOLE. REMOVE ANY LOOSE ITEMS SUCH AS GRATES AND BURNER CAPS FROM THE TOP OF THE RANGE, THEN CAREFULLY TILT THE RANGE FORWARD TO ENSURE THAT THE ANTI-TIP DEVICE PRDS304 AND PRDS36 Dual-Fuel Ranges (Figures 11, 14 and 15) STEP A: Determine the best location for AntiTip Channel Mounting Bracket. The bracket may be mounted to the wall or floor behind the range, offset from side wall as indicated in the chart below and in Figures 14 and 15: For Model PRDS304, the dimensions shown are from the left side wall only. For Model PRDS36, the dimensions shown are from either the left or right side wall. Locate the bracket on the side of the range that will not interfere with the gas supply line, electrical wiring, conduit or any other item. Select either the rear wall or the floor for mounting the bracket, based upon which will provide the greatest holding strength. Model No. 16-1/2" 13-1/2" - Page 13 STEP H: Using the 1/4"-20 x 1/2" Hex Head Bolt, Hex Nut and two (2) Flat Washers, securely attach the Adjustable Anti-Tip Channel to the existing hole in the flange located at the bottom rear of the range. (There are two (2) holes in the range flange, so be certain to select the hole that is on the same side as the mounting bracket. ) The flat face of the channel should be flush against the underside of the range flange. From the bottom of the channel, screw the two (2) #10 x 1/2" Phillips Screws up through the first pair of holes extending beyond the rear edge of the range flange. Note: A number of mounting holes are provided in the Adjustable Anti-Tip Channel. Be certain to use the hole that enables the channel to engage the mounting bracket when the range is in its final installed position. For ranges that are to be installed flush against a rear wall, use the first hole in the Adjustable Anti-Tip Channel, such that the short portion of the channel extends out from the bottom of the range flange and the long portion is hidden beneath the range. 13 PRG36 Floor Mount PLAN VIEW Anti-Tip Channel Mounting Bracket PRG304: 2-3/4" PRG36: 4-5/8" Anti-Tip Channel Mounting Bracket STEP 4: INSTALLING ANTI-TIP DEVICE STEP B: Set the bracket on the floor and turn it until it is oriented properly. The long channel should be on the top with the free end facing towards you, one set of mounting flanges should be resting horizontally on the floor, and the other set of mounting flanges should be positioned vertically facing the rear. "B") spacing from the side wall to the center line of the closest bracket mounting hole is as shown in the chart above and in Figures 14 and 15. STEP D: If you plan to mount the bracket to the rear wall, slide the bracket back until it is positioned against the rear wall. [. . . ] For discolorations or deposits that persist, refer to the Care and Use Manual. To polish and protect the stainless steel, use a cleaner/ polish such as Stainless Steel Magic®. DO NOT allow salt solutions, disinfectants, bleaches or cleaning compounds to remain in contact with stainless steel for extended periods. Rinse with water after exposure and wipe dry with a clean cloth. Page 22 INSTALLERCHECKLIST FINAL CHECK LIST Placement of unit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 15-12-596C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 15-12-596C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.