User manual THERMADOR 14-33-873F

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THERMADOR 14-33-873F. We hope that this THERMADOR 14-33-873F user guide will be useful to you.


THERMADOR 14-33-873F : Download the complete user guide (494 Ko)

Manual abstract: user guide THERMADOR 14-33-873F

Detailed instructions for use are in the User's Guide.

[. . . ] I UL LISTED #157J FILE # E521958 INSTALLATION INSTRUCTIONS MANUAL 30" BUILT-IN RANGES WITH COOK'N'VENT ELECTRIC MODEL RED30V DUAL-FUEL MODEL RDDS30V PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: INSTALLER: OWNER: WARNING: Save these instructions for the local electrical inspector's use. Please leave these Installation Instructions with this unit for the owner. Lock service panel to prevent power from being turned ON accidentally. Avant l'installation, COUPER au tableau de service, et fermer a clef le tableau de service pour empecher l'alimination d'etre allumée per hasard. AVERTISSEMENT: IMPORTANT: LOCAL CODES VARY. [. . . ] Based on the type of ventilation (integral or remote blower) proceed with directions either 1 or 2. Units using Integral Blower: The integral blower is furnished with a cord and connector. Insert cord connector into receptacle located in lower right plenum bottom. See Figure 7. Integral Blower Front Rail Receptacle Plenum Opening Figure 7 ­ Blower Cord Connection Blower Cord OVEN FRONT 2. Units using Remote Blower: a) Wiring the Remote Blower Wire connections between the range and remote blower shall be made as follows: 1. Grasp the five wires and cut as close to molded connector as possible. Remove plug from electric "knockout" from plenum bottom (right front corner). Secure remote blower flex conduit/wiring to plenum conduit connector, 4. Connect color coded range wires to remote blower wires using wire nuts or approved splices. Reinstall plenum cover and front rail. Figure 8 ­ Remote Blower Wiring Plenum Opening Removable Plenum Cover Screws Wiring Compartment To Remote Blower Duct Attachment Box Removable Front Rail K. O. 's Location Range Front Figure 9 ­ Range - Remote Blower Electrical Connection Range White Black Red Blue Black Blue Red White Red Molded Connector Remote Blower Blue White Black Green Green 7 I INSTALLING THE VENTILATION INSTALLING A REMOTE BLOWER CAUTION - For general ventilating use only. NOTE: Remove and discard shipping bracket (attached to bottom of motor and inlet collar). Provide a square hole through the roof (or wall), as shown by dashed lines, or cut a round hole to fit duct with a separate hole for electrical conduit as shown by solid lines in Figure 10. Install the Remote Blower on the roof or wall (with discharge pointing down slope) according to the Standard Roofing Procedures (front discharge edge should be on the top of shingles and the rear edge underneath the shingles). VTR600R 10" dia VTR1000Q 14" 6-1/8" 1" 1" 4-11/16" for VTR600R 6-1/4" for VTR1000Q 1-1/4" Hole 14" Figure 11 ­ Curb for roof 20-3/4" 28" Figure 12 Remote "J" Box Blower Dimensions A Adjustable Elbow 9-3/8" C 11-3/8" 5-7/8" G D E F 20-3/4" 28" H Conduit (Not Provided) Tape Joints B Dia. 10-3/8 D 10-1/4 11-1/4 E 3-3/16 4-5/8 F 17-5/8 14-1/2 G 10-3/4 8-3/4 H 10 8 I 26-1/4 24 NOTE: The unit must be sealed between the roof (or wall) and the underside of the flange with roofing mastic to prevent leaks. For installation on a flat roof, or roofs with a pitch less than 1-1/2" in 12", install ventilator on the curb as shown in Figure 11. Position the curb on flat roofs so that the discharge (low) end points away from prevailing wind. 8 I J 4 3-1/2 2" 5-1/2" INSTALLING THE VENTILATION I 4. The duct put into the unit inlet blower should be taped at the joint and the inlet collar. Figure 13 SAFETY WARNING: Before wiring the unit, turn off the proper circuit at the service box. 6. Run electrical conduit up through extruded hole in bottom of the remote blower. Run five #14 AWS wires (white, red, blue, black and green) to the conduit, (Fig. 13). For the wire connection between the remote blower and range see page 7 and Figs. [. . . ] Note that the chart legend furnishes different lines for different ducting sizes and shapes. By using the correct line, you can see that 45 feet of rectangular duct equates to approximately 420 C. F. M. 15 I BLOWER DUCT SIZING 16 BLOWER DUCT SIZING I EQUVILANT LENGTHS OF FITTINGS 3-1/4 " x 10" to Round 3-1/4 " x 10" x to Round 90° Elbow TABLE 1 90° Elbow Wall Cap Fitting = Straight (Dia. ) Length 6" = 5 Ft. Model #129517 Fitting = (Dia. ) 6" = 7" = Round to 3-1/4 " x 10" Round to 3-1/4 " x 10" 90° Elbow Fitting = Straight (Dia. ) Length 6" = 1 Ft. Model #129517 3-1/4 " x 10" 90° Elbow Model # 12557 Fitting = (Dia. ) 6" = 7" = Straight Length 10 Ft. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 14-33-873F




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 14-33-873F will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.