User manual THERMADOR 14-10-387E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THERMADOR 14-10-387E. We hope that this THERMADOR 14-10-387E user guide will be useful to you.


THERMADOR 14-10-387E : Download the complete user guide (83 Ko)

Manual abstract: user guide THERMADOR 14-10-387E

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION, ELECTRICAL CONNECTIONS AND GROUNDING MUST COMPLY WITH ALL APPLICABLE CODES. Check your local building codes for the proper method of installation. In the U. S. A. , if there are no applicable local codes, this unit should be installed in accordance with the National Fuel Gas Code #Z223. 1-Current Issue, and the National Electrical Code ANSI/NFPA No. (In Canada, installation must be in accordance with the CAN 1-B149. 1 and . 2 - Installation Codes for Gas Burning Appliances and/ or local codes). MOBILE home installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 {formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280)} or, when such standard is not applicable, the Standard for Manufactured Home Installations, ANSI A255. 1 / NFPA501A, or with local codes. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. [. . . ] This kit includes instructions for adjusting valves and pressure regulator and contains new burner jets. The RDDS model is equipped with an intermittent/interrupted ignition device (ExtraLow®). NATURAL GAS The cooktop is shipped from the factory for use with natural gas only. The gas supply to the appliance regulator must be a minimum of 6. 0" water column. The maximum gas pressure to the range regulator shall not exceed 14" W. PROPANE GAS CAUTION: When connecting unit to propane gas, make certain the propane gas tank is equipped with its own high pressure regulator in addition to the pressure regulator supplied with the appliance. The gas supply to the appliance regulator must be a minimum of 11. 0" water column. The maximum gas pressure to the appliance regulator is not to exceed 14. 0" water column from the propane gas tank. ATTENTION: En branchant l'appareil au gaz de propane, soyez certain que le réservoir de gaz du propane est équipé avec son régulateur de haute pression en addition du régulateur de pression fourni avec cet appareil. La founriture de gaz au régulateur de l'appareil doit être un minimum de 11. 0" colonne d'eau. La pression de gaz maximale à cet appareil ne doit pas excéder une colonne d'eau de 14. 0 pounces du régulateur du réservoir de gaz du propane. 5 1-3/4" From Wall IMPORTANT NOTES (a) The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3. 5kPa). Run five #14 AWS wires (white, red, blue, black and green) to the conduit, (Fig. 13). For the wire connection between the remote blower and range see page 7 and Figs. 8 & 9. VENTILATION I The range is equipped with a factory installed ventilator intake and an exhaust plenum which will not be shipped separately. The plenum exhaust outlet is located below the oven in the base area shown in Fig. 14. An Integral Blower Model VTN30Q or Remote Model VTR1000Q Blower System must be installed with the range. INSTALLING AN INTEGRAL BLOWER THE VTN30Q blower may be mounted prior to or after range installation depending on duct and taping variables. The integral blower housing inlet (See Figure 15) fits over the plenum outlet ring (Figure 14), and is secured to the plenum with a blower mounting bracket. The blower may be rotated in various directions to achieve right side, left side, rear or floor venting. Threaded rods included in the blower kit will be secured to the mounting nuts "A" or "B" shown in Figure 15. Further installation instructions are specified in the following sections. Figure 14 ­ Bottom View of Exhaust plenum Up Front B A Plenum Exhaust Outlet B A Figure 15 ­ Integral Blower Vent to Side Back and Floor FFO FF O FF O Blower Inlet Threaded Rods Mounting Bracket 9 I VENTILATION INTEGRAL BLOWER - RIGHT OR LEFT DUCTING 1. [. . . ] FOR EXAMPLE: An internal ventilation system, using model VTN30RQ, would have a total equivalent length of 45 feet when using fittings noted on Page 17. Duct Fitting Equivalent Quantity Fitting Equivalent Description Length 1 6" Dia to 3-1/4" x 10" 1 Ft. Total "A" Duct Fitting Equipment 23 Ft. Adapter Mounting Bracket 15 Ft. Once you've determined the value of C, refer to Chart 1 for internal blower (Page 16) to find the minimum C. F. M. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 14-10-387E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 14-10-387E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.