User manual THERMADOR 08-04-638B

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THERMADOR 08-04-638B. We hope that this THERMADOR 08-04-638B user guide will be useful to you.


THERMADOR 08-04-638B : Download the complete user guide (290 Ko)

Manual abstract: user guide THERMADOR 08-04-638B

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Instructions and Owner's Manual for Thermador Outdoor Cooktop Model SB2B Installer: Owner: Please leave these instructions with the unit for the owner. L WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. AVERTISSEMENT: Si l'information dans ce manuel n'est pas suivie exactement, une incendie ou une explosion peut résulter, entrainant des dégats matériels, des blessures ou la mort. !L A Special Message to Our Customers Thank you for selecting the Thermador® Outdoor Cooktop. We recommend that you take time to read this entire booklet before using your new appliance for the first time. [. . . ] Manifold Pressure: 5" W. C. PROPANE GAS REQUIREMENTS Inlet Connection: 1/2" NPT Supply Pressure: 11" to 14" W. C. Manifold Pressure: 10" W. C. IMPORTANT A manual gas shut off valve must be installed external to the appliance, in a location accessible with the unit installed in the enclosure. Make sure the valve is turned off prior to connecting the appliance. IMPORTANT Un robinet manuel d'isolement doit étre installé à l'extérieur de l'appareil, dans un emplacement accessible avec l'unité installée dans la module. Assurez-vous que le robinet est fermé avant de brancher l'appareil. !The 8-foot-long electrical cord attached to the cooktop exits from the bottom, left rear corner of the rough-in box. Keep connections to the unit as short as possible and allow for installation and removal of the unit from the enclosure. Allow adequate area around the unit for dissipation of smoke produced during cooking. CABINET PREPARATION The model SB2B is designed for easy installation into masonry enclosures. For noncombustible applications, the cooktop drops into the opening shown in Figure 1 (below). It is recommended that ventilation holes are provided in the enclosure in the event of a gas leak. The installersupplied gas shut-off valve must be installed in an easily accessible location. Figure 1 Non-Combustible Enclosure for SB2B Cooktop Combustible Construction Clearances Minimum horizontal clearance from sides and back of unit to adjacent vertical combustible construction extending above top of unit, 12" from sides and 12" from back. Degagement horizontal minimal a respecter entre les cotes et l'arriere de l'appareil et une construction combustible verticale adjacent depassant la partie superieure de l'appareil, soit 12" (305mm) pounces des cotes et 12" (305mm) ponces de l'arriere. Below the cooking surface, combustible construction can be placed directly adjacent to the unit. 36" 3" Min. 12-5/8" 22-3/4" 36" 11-3/4" Non-combustible Construction Clearances Above the cooking surface, a minimum of 12" clearance from the sides is required to allow adequate access to pans. A minimum of 3" clearance from the rear is required to allow for large pan sizes. Below the cooking surface, non-combustible construction can be placed directly adjacent to the unit. In all installations, do not locate this outdoor cooking gas appliance under unprotected combustible overhead construction. II est interdit d'installer le present appareil au-dessous des surfaces combustibles non protegees. 2" x 4" x 18" WOOD SUPPORT 6 SECTION 4: ELECTRICAL REQUIREMENTS AND GROUNDING INSTRUCTIONS CAUTION Installation of electrical supply circuit should be done by a qualified electrician in accordance with local codes and ordinances. In the absence of local codes or ordinances, the supply should be installed in accordance with the National Electric Code ANSI/NFPA No. 70, current issue, or Canadian Electric Code C22. 1 Part 1. CAUTION The Thermador® Outdoor Cooktop uses an electronic ignition system that requires a 120 VAC, 15A, 60 Hz power supply. A properly grounded duplex outlet must be provided adjacent to the lower left rear corner of the unit. See Figure 2 (below). WARNING Electrical Grounding Instructions This outdoor cooking gas appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. [. . . ] Keep your invoice for warranty validation. __________________________________ Model Number __________________________________ Serial Number __________________________________ Date of Purchase __________________________________ Dealer's Name __________________________________ Dealer's Phone Number __________________________________ Service Center's Name __________________________________ Service Center's Phone Number 15 To Obtain Replacement Parts, order from the dealer where the unit was purchased or dial the telephone number listed below. HOW TO OBTAIN SERVICE For authorized service or parts information, phone 800/735-4328. If a problem does come up that cannot be resolved to your satisfaction, please let us know. Write: Thermador® Customer Call Center, 5551 McFadden Avenue, Huntington Beach CA 92649 or phone 800/735-4328. Please provide us with the Model Number, Serial Number and Date of Original Purchase/ Installation. SECTION 10: WARRANTY Warranty Full One-Year Warranty Covers one year from the date of installation or date of occupancy for a new previously unoccupied dwelling. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 08-04-638B




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 08-04-638B will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.