User manual THERMADOR 08-04-439D

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THERMADOR 08-04-439D. We hope that this THERMADOR 08-04-439D user guide will be useful to you.


THERMADOR 08-04-439D : Download the complete user guide (1908 Ko)

Manual abstract: user guide THERMADOR 08-04-439D

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Instructions for Thermador Char Glo® Outdoor Barbecues Models: CGBD30RX · CGBD36RX CGBD48RSBX · CGBD48RX CGBD30RX CGBD36RX CGBD48RSBX Installer: Owner: Please leave these instructions with the unit for the owner. L WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. AVERTISSEMENT: Si l'information dans ce manuel n'est pas suivie exactement, une incendie ou une explosion peut résulter, entrainant des dégats matériels, des blessures ou la mort. !L Inside Front Cover ­ Blank Contents SECTION 1: Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SECTION 2: Gas Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Insure that the gas supply line and electrical supply are located in close proximity to the unit to keep connections to the unit as short as possible and allow for installation and removal of the unit from the enclosure. Allow adequate area around the unit for dissipation of smoke produced during cooking. CABINET PREPARATION The models CGBD30, CGBD36 and CGBD48 are designed for easy installation into masonry enclosures. For noncombustible applications, the barbecue drops into the opening shown in Figures 3 and Fig. Models CGBD36 and CGBD48 also require a ledge in the center of the opening to support the middle of the unit. It is recommended that ventilation holes are provided in the enclosure in the event of a gas leak. The installersupplied gas shut-off valve must be installed in an easily accessible location. Properly Grounded 3-Prong Receptacle 3" MINIMUM FOR LID CLEARANCE F NON-COMBUSTIBLE ENCLOSURE E 3" minimum for hood clearance to back wall E 36" 12" C 12" OPENING FOR ACCESS DOOR GAS INLET F A © Center Support Ledge for CGBD36 and CGBD48 D 36 B Figure 3 12" Figure 4 Cutout Dimensions for 30", 36" and 48" Built-in Units CLEARANCES (Refer to Figures 3 and 4) CharGlo® Outdoor Barbecues Model No. Overall Dimensions A CGBD30RX CGBD36RX CGBD48RSBX CGBD48RX 24-3/4 24-3/4 24-3/4 24-3/4 B C Cutout Dimensions D E F 22-3/4 30-7/16 26-5/8 36 48 48 26-5/8 26-5/8 26-5/8 11-15/16 29-3/4 11-15/16 35-5/16 22-3/4 11-15/16 47-5/16 22-3/4 11-15/16 47-5/16 22-3/4 All Char-Glo® Outdoor Barbecues are CGA and AGA approved. Note: All height width and depth dimensions are shown in inches. Page 5 SECTION 3: SITE PREPARATION To combustible construction Below the cooking surface, combustible construction can be placed directly adjacent to the unit. Allow 8" clearance at the lower left rear of the unit for adequate routing of the gas and electrical supply line. Minimum horizontal clearance from sides and back of unit to adjacent vertical combustible construction extending above top of unit, 12" from sides and 20" from back. Degagement horizontal minimal a respecter entre les cotes et l'arriere de l'appareil et une construction combustible verticale adjacent depassant la partie superieure de l'appareil, soit 12" (305mm) pounces des cotes et 20" (508mm) ponces de l'arriere. Below the cooking surface, non-combustible construction can be placed directly adjacent to the unit. Clearance of 8" at the lower left rear of the unit must be maintained to allow adequate routing of the gas and electrical supply lines. In all installations, do not locate this outdoor cooking gas appliance under unprotected combustible overhead construction. II est interdit d'installer le present appareil au-dessous des surfaces combustibles non protegees. To non-combustible construction Above the cooking surface, a minimum 8" clearance from the sides is required to allow use of the rotisserie motor and skewer. A minimum of 3" clearance from the rear is required to allow proper opening of the hood. Cabinet access doors Cabinet access doors are available for the Thermador Drop-In barbecues. Model CAD30 is for use with barbecues CGBD30; Model CAD36 is for use with barbecues CGBD36, CGBD48SB or CGBD48R. Contact your Thermador dealer for additional information. Page 6 SECTION 4: ELECTRICAL REQUIREMENTS AND GROUNDING INSTRUCTIONS CAUTION CAUTION Installation of electrical supply circuit should be done by a qualified electrician in accordance with local codes and ordinances. In the absence of local codes or ordinances, the supply should be installed in accordance with the National Electric Code ANSI/NFPA No. The Thermador® Char Glo® barbecues use an electronic ignition system that requires a 120 VAC, 15A, 60 Hz power supply. A properly grounded duplex outlet must be provided adjacent to the lower left rear corner of the unit. The conversion should be done by a qualified technician or your gas supplier. Make sure that the unit is disconnected from the gas and electrical supplies. [. . . ] Check the connection points at the shutoff valve for any leaks and repair prior to installation of the unit. Connect the power supply cord to the electrical supply outlet. © Bottom of Unit Leak Test Points Check hose for signs of abrasions, cracks or leaks LP Tank © Test Leak Points Figure 12 Figure 13 Page 11 SECTION 6:TEST AND ADJUSTMENT CHECKING FOR LEAKS All points of connection to the gas supply should be manifold. It is also advisable to recheck them Tighten any leaking fittings, turn on the gas and periodically. for leaks at all points of connection in the control Turn on the gas supply to the unit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 08-04-439D




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 08-04-439D will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.