User manual THERMADOR HMWN30FS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THERMADOR HMWN30FS. We hope that this THERMADOR HMWN30FS user guide will be useful to you.


THERMADOR HMWN30FS : Download the complete user guide (3996 Ko)

You may also download the following manuals related to this product:

   THERMADOR HMWN30FS annexe 1 (1373 ko)

Manual abstract: user guide THERMADOR HMWN30FS

Detailed instructions for use are in the User's Guide.

[. . . ] V E N T I L AT I O N I N S TA L L AT I O N M A N U A L MODELS: HMWN30 HMWN36 HMWN48 LI3J1A Ed. 08/08 APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical Inspector's use. INSTALLER: Please leave these Instructions with this unit for the owner. [. . . ] Le réducteur devra être ins tallé du côté « extérieur » de l'amortis s eur thermique, lequel doit s e trouver le plus proche pos s ible du point où le conduit d'èvacuation entre dans la zone chauffée de la mais on. S ys tèmes de ventilation : La réglementation en vigueur dans votre lieu de rés idence peut exiger l'utilis ation de sys tème de ventilation rés identiel additionnel lors que vous utilis ez des appareils de ventilation/extraction d'air qui requièrent l'ins tallation de conduits d'èvacuation et dont la puis s ance es t s upérieure aux s pécifications C F M de courants d'air . Les normes et s pécifications C F M varient s elon le lieu de rés idence : cons ultez votre profes s ionnel HVAC pour connaître les normes et s pécifications applicables à votre lieu de rés idence. 16 Installation typique La hauteur entre le plan de travail de votre cuisine et la ligne inférieure de la hotte soit osciller entre 24 et 30 pouces. Il n'est pas recomandé d'utiliser ce type de hotte aspirante au-dessus d'un grill d'interieur. 1. Choisissez le type de ventilation désirée. Note: voir également Fig. 1-2-3 pour la préparation de l'installation sur meuble. Exemples de possibles types d'extraction/evacuation Conduit d'extraction rond Plafond Transition Ventilateur Lampe Hotte *Flitre à charbon Plafond Lampe Hotte Ventilateur *Fitres à charbon 30" a 36" 30" a 36" Recyclage *Accessoire optionnel ­ kit de recyclage d'air sans conduit. *Uniquement pour les 30 "et 36" avec le système de soufflerie intégrante VTN006F Décharge verticale 17 Tabla 1. Calcul de performances de ventilation Ajustage/dimensions Utilisez ce tableau pour calculez les dimensions maximum autorisées pour la connexion de la hotte à l'extérieur. Nota : ne pas depasser les équivalences de dimensions maximale autorisées. Longueur maximale de conduits autorisée pour ce type de hottes : 150 pieds. Conduits flexibles : Si vous utilisez des conduits en métal flexible, le conduit metallique doit être souple, droit et le plus déplié/étendu possible. NE PAS UTILISER DE CONDUIT EN PLASTIQUE FLEXIBLE. Note: Tout système de ventilation domestique, tel qu'une hotte aspirante peut interrompre le cours normal de la combustion de l'air ainsi que la ventilation naturelle que demandent des installations telles que des cheminées ­ á bois ou á gaz Pieza 10" rond a 8" rond Rond droit 3-1/4" x 10" 3-1/4" x 12 " droit coude de connexion 90° coude de connexion 45° 3 -1/4" x 12" 3-1/4" x 10" coude 90° 3-1/4" x 10 " 3-1/4" x 12 " coude 45° 3-1/4" x 10" 3-1/4" x 12" coude plan 90° transition ronde 10" de 3-1/4" x 10" o 3-1/ 4" x 12" 3-1/4" x 10" o 3-1/4" x 12" a 10" Connexion ronde de 10" 3-1/4" x 10" coude 90° de 3-1/4" x 12" transitions 3-1/4" x 10 " 3-1/4" x 12" o rond de 10" coude de 90° Calotte murale ronde avec atténuateur. Calotte murale ronde avec atténuateur de 3-1/4" x 10" 3-1/4" x 12" Calotte ronde pour le toit. Largo equivalente* Cantidad usada Largo total 5 ft. 36 ft. 9 ft. de la ventilation de ces systèmes, suivez les recommandations de sécurité et installation du fabricant ainsi que les normes et réglementation tels que celles publiées parla NFPA et la ASHRAE. 6 ft . 26 ft. Ces hottes aspirantes doivent d'être équipées de conduits de 10 pouces. *C es hottes s ont fournies avec des connexions /trans itions rondes de 10 pouces. Il vous faudra vous procurez s ur votre lieu de rés idence toute connexion ou réducteur nécés s aire pour effectuer l'adaptation á des conduits d'autres dimens ions. Note: la sortie qui se trouve sur le dessus de la hotte est de 8-1/8 pouce x(par) 8 pouces D ucto T otal 18 Table 2. Instructions d'installation des conduits Pour des raisons de sécurité, l'exactration des fumées et vapeurs de cuisson doit se faire directement vers l'extérieur du bâtiment. Ne pas évacuer les fumées et vapeurs de cuisine vers les colonnes sèches, les espaces existant entre deux murs, les espaces sous plancher ou des greniers. Faites en sorte que les conduits soit aussi court et droits que possible. Les connexions et réducteurs de taille de conduit, réduise le volume d'air qui est evacué. [. . . ] Nota: Si es posible fije la campana en cuatro puntos adicionales (2 en la parte de arriba, 2 en la parte de abajo). De adentro del gabinete fije la transición en la salida de arriba. 31 Gancho para instalación a pared. Tornillo de intalación a fondo de gabinete Tornillo de ajuste. Fondo de gabinete. Figura 4b Fix Duct to transitionand seal withtape. For both ins tallation method : 10. Wiring the HOOD: WARNING: To Avoid Electrical Shock Hazard The integral motor blowers should be installed to the hood with the hardware provided (Machine screws, millimetric screws, millimetric nuts, motor bracket and spring) in the VTN600F and VTN1000F hardware bags. panel before wiring this unit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR HMWN30FS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR HMWN30FS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.