User manual THERMADOR 5060002295E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THERMADOR 5060002295E. We hope that this THERMADOR 5060002295E user guide will be useful to you.


THERMADOR 5060002295E : Download the complete user guide (244 Ko)

Manual abstract: user guide THERMADOR 5060002295E

Detailed instructions for use are in the User's Guide.

[. . . ] 4) You can fight the fire with your back to an exit. PAGE 2 FEATURES 1 5 2 0 1 2 3 3 4 6 RAISED INTAKE 1 2 3 Intake Top Cap UP/DOWN Push-button Blower Speed Control Knob 4 5 6 Front Panel Filters (behind front panel) Blower (not shown) The Thermador Universal Cook`n'Vent® takes the place of an overhead hood and can be conveniently hidden away (lowered) when not in use. There are five primary parts of the Universal Cook`n'Vent® downdraft system that will be referred to in this booklet: The Intake, the UP/DOWN Push-button, the Blower, the Blower Speed Control Knob and the Filters. The Blower Speed Control Knob The Intake The intake, when raised, captures and channels the cooking odors, steam and grease. The filters are located within the intake. UP/DOWN Push-button 0 1 2 3 The UP/DOWN push-button is located on the top right of the intake. It is not necessary to hold the push-button. The Blower The blower speed control knob is located on the right front of the intake. There are four blower speed settings represented by numbers "0" (Off) , "1" (Low), "2" (Medium), and "3" (High). Filters The blower is the fan that draws the cooking odors out of the house. The filters are located just behind the removable front panel with the Intake. [. . . ] The cleaners recommended below indicate a type and do not constitute an endorsement. Use all products according to package directions. A Anodized Aluminum Top Cap for Stainless Aluminum Mesh Filters Top cap is not removable. Wash top and underside with hot sudsy water. Rinse and wipe dry or apply Fantastic® or Formula 409® first to a clean sponge or paper towel and wipe clean. Rinse and dry. B C Plastic UP/DOWN Push-button, Control Knob Painted Top Cap for Black/White Stainless Steel Front Panel & Back Wall D Top cap is not removable. Wash top and underside with hot sudsy water. Rinse and wipe dry or apply Fantastik® or Formula 409® first to a clean sponge or paper towel and wipe clean. Wipe with Fantastik® or Formula 409® sprayed onto a paper towel. Polish with Revere Ware® Metal Polish or Stainless Steel Magic® and a soft cloth. Use Revere Ware® Instant Stainless Steel Cleaner to remove heat discoloration. E To Re-Assemble the Intake 1. Place the filters inside the intake, side by side, on the slats in front of the back wall. They will lean forward and the tops of the outside two will rest against the support bars. Holding the front panel at the top near the sides, place bottom edge over front lower sill of the intake. Keeping the panel vertical, hook the top of the front panel to the intake. PAGE 5 CARE AND CLEANING OCCASIONAL COOK`N'VENT® CARE Approximately every six months, remove any food soil that may have collected behind the access panels. The 30" and 36" models have two removable access panels; the 45" model has 3 panels. The access panels to the "clean out" area are beside the blower (cabinet installation) or duct transition (remote blower installation). The electrical connection box above the clean out area must be accessible for electrical inspection or service only. DO NOT TOUCH OR CLEAN the electrical connection box. Electrical Connection Box: DO NOT OPEN Intake Data Plate "Clean Out" Area 2 Access Panels (3 in 45") Mounting Channel Cabinet Blower Wing Nuts VTN600R CABINET BLOWER INSTALLATION AND ACCESS PANELS TO REACH THE CLEAN OUT AREA 1. Unscrew the wing nuts on the top of the access panels as illustrated above. Wipe up any accumulated grease or food in the "clean out" area. Be careful when working around the metal framework of the" clean out" area as there may be sharp edges. PAGE 6 CUSTOMER SERVICES WARRANTY THERMADOR ® COOK`N'VENT ® WARRANTY CVS30R, CVS36R AND CVS45R WHAT IS COVERED Full One Year Warranty For one year from the date of installation or date of occupancy for a new previously unoccupied dwelling, any part which fails in normal home use will be repaired or replaced free of charge. Save your dated receipt or other evidence of the installation/occupancy date. [. . . ] Keep your invoice for warranty validation. To obtain service, see back cover. PAGE 7 CUSTOMER SERVICES BEFORE CALLING FOR SERVICE · Ensure that the electrical cord is properly connected and the supply circuit is energized. If the blower does not operate: · Check that the intake is fully raised. · Make sure that the blower speed control knob is not in the OFF position, "0". HOW TO OBTAIN SERVICE For authorized service or parts information, call 1-800-735-4328. We want you to be a satisfied customer. If a situation arises that has not been resolved to your satisfaction, please let us know. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 5060002295E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 5060002295E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.