User manual THEBEN ECO-IR 360 SCHEMA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THEBEN ECO-IR 360. We hope that this THEBEN ECO-IR 360 user guide will be useful to you.


THEBEN ECO-IR 360 SCHEMA: Download the complete user guide (87 Ko)

Manual abstract: user guide THEBEN ECO-IR 360SCHEMA

Detailed instructions for use are in the User's Guide.

[. . . ] The sensors must be secured firmly with the safety locking device after the upper part has been connected (Fig. 3 "Light" switching contact The switching contact closes if the brightness level is too low and if the presence of a person is detected. Important The ECO-IR is designed for use in combination with fluorescent lamps (FL operates with standard ballasts) and energy saving lamps (PL). 1 2 3 4 5 6 7 8 9 Safety Function and performance characteristics Mounting and connecting the device Applications Putting the device into operation Warranty Copyright Troubleshooting Technical data (rear of instruction manual) Danger All work on the 230 V power supply must be performed by authorized trained personnel only. [. . . ] 1 2 3 4 5 6 7 8 9 Safety Function and performance characteristics Mounting and connecting the device Applications Putting the device into operation Warranty Copyright Troubleshooting Technical data (rear of instruction manual) Danger All work on the 230 V power supply must be performed by authorized trained personnel only. Incorrect handling of the device can lead to serious injury or cause With indirect lighting, ensure that the main part of the light from these lamps is not directed at the detector as this affects the daylight measurement. When using suspended lighting, we recommend that you integrate the detector directly in the lamps or provide a sufficient lateral clearance. When using suspended lighting, note that the detection range may be shaded. unlike the "Light" switch-off delay time , the "HVAC" switch-off delay time is not adjusted by the ECO-IR. Note The switch-off delay times are restarted each time a movement is detected. The switch-off delay is fixed, there is no selflearning effect, the switch-off delay remains constant. Both ECO-IR models must be mounted in housings (surface-mounted or concealed installation, single housing) (Fig. 2 Preparations First pull out the left and right-hand safety locks up to the limit stop using a screwdriver to separate the sensor head from the power section (Fig. - Neutral to N - Phase to L - Phase connected to Aî - "HVAC" to B1, B2 Connecting several units in parallel The outputs (Aî) of several ECO-IR units can be connected in parallel as shown in Fig. HTS therefore guarantees that all of the models in the ECO-IR series will function correctly provided that they are used in the prescribed manner. Should the system prove to be defective, however, HTS will provide the following warranty: The warranty period is 1 year from the date of invoice. The warranty is excluded if the goods supplied become damaged due to improper handling or are used in a manner contrary to the specifications, standards and instructions, in particular, contained in the product description. The warranty and liability with regard to subsequent damage to the assembled device for devices integrated in a software-controlled system are limited to maintenance of the interface specification. Liability for damage does not include damage due to transportation or damage as a result of non-compliance with the specifications contained in the operating instructions or with the instructions for correct installation. HTS must be allowed the time and opportunity required to rectify the defect. Submission In the event of a warranty claim, the device should be sent with the delivery certificate and a brief description of the fault to the relevant dealer or, if purchased directly, to HTS. The design, hardware and software of these devices are protected by patent. ECO-IR® is a registered trademark, the use of which is subject to the approval of HTS. The detector does not switch off after 90 s Immediate response to change in brightness Cause Both outputs are closed for 90 s after the detector has been connected (test phase) The detector may respond more slowly in accordance with the switch-off delay time The device is in service phase (10 minutes) This phase is used to adjust the brightness setting Remedy Wait for 90 s. [. . . ] The design, hardware and software of these devices are protected by patent. ECO-IR® is a registered trademark, the use of which is subject to the approval of HTS. The detector does not switch off after 90 s Immediate response to change in brightness Cause Both outputs are closed for 90 s after the detector has been connected (test phase) The detector may respond more slowly in accordance with the switch-off delay time The device is in service phase (10 minutes) This phase is used to adjust the brightness setting Remedy Wait for 90 s. The device then responds immediately to changes in brightness for 10 minutes. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THEBEN ECO-IR 360




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THEBEN ECO-IR 360 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.