Manual abstract: user guide TEXECOM VERITAS R8

Detailed instructions for use are in the User's Guide.

[. . . ] If more than one zone is open the bleeps will correspond to the highest zone number (i. e. If it is necessary to leave a zone open then it must be omitted (see "To OMIT Zones During Setting" below). Your Installer can program the system so that it can be set using the " or % keys without the need to first enter a User code. To PART Set the System Ensure all zones in the intended Part Set area are closed. [. . . ] The internal and external sounders will stop but the external strobe will continue to flash. The display will flash the zone light of the zone which first caused the alarm activation and illuminate the zone lights of all subsequently opened zones (if any). 4 INS036-5 To RESET After an Alarm Activation After an alarm activation the internal and external sounders will stop after a pre-set time. The system will re-arm but the external strobe will continue to flash. The display will flash the zone light of the zone which first caused the alarm activation and illuminate the zone lights of all subsequently opened zones (if any). The system will chime and return to unset. If the System Requires an Anti-Code After an Alarm Activation The system may be programmed to require an Anti-Code after an alarm activation. You will still be able to silence the alarm by entering your code as normal. However you will not be able to reset the system without first obtaining the Anti-Code. Contact the phone number on the last page with this sequence in order to obtain a 4 digit Anti-Code which will allow the system to be reset. The zone light of the zone which first caused the alarm activation will flash, and the zone lights of all subsequently opened zones (if any) will illuminate. To return to the random sequence display press ( again. The CHIME Facility When the system is unset it is possible to set one or more zones to Chime. When a zone is set to Chime the control panel will sound a tone whenever the zone is entered. To Program the Zones which CHIME To program the zones which will chime enter your 4 digit code !!!!. Press ' to turn Chime on (the system will sound the chime tone) or press ( to turn Chime off (the system will sound an error tone). INS036-5 5 To Turn CHIME On or Off To turn Chime on or off press ). The system will sound the chime tone when Chime is turned on and an error tone when Chime is turned off. If no zones have been programmed to Chime then turning Chime on and off will have no effect. To Test the Sounders and Strobe The control panel has a test facility to check the operation of the internal sounder, the external sounder and strobe. The system outputs may be tested as follows: Key System Output Internal sounder at high level (alarm level) Internal sounder at low level (entry/exit level) Strobe External sounder (bell) Turns off all of the above . , $ # * The zone light corresponding to the number pressed will illuminate. The system will return to unset and all the zone lights will turn off. To Display Log Events The control panel is capable of recalling the last 7 alarm activations. [. . . ] Zone lights 1, 2, 3 and 4 will illuminate in turn as each digit of the new code is entered. The system will chime to confirm the new code has been accepted and all the zone lights will illuminate. The system will return to unset and all the zone lights will turn off. If Your System is Due for Maintenance The system has a service timer which may be programmed by the installer to give a reminder when maintenance in due. The reminder may be either turning Chime on or preventing the system from being set. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEXECOM VERITAS R8




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TEXECOM VERITAS R8 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.