User manual TEXECOM PREMIER 412

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TEXECOM PREMIER 412. We hope that this TEXECOM PREMIER 412 user guide will be useful to you.


TEXECOM PREMIER 412 : Download the complete user guide (1271 Ko)

You may also download the following manuals related to this product:

   TEXECOM PREMIER 412 MANUEL D INSTALLATION (1569 ko)
   TEXECOM PREMIER 412 (495 ko)
   TEXECOM PREMIER 412 BROCHURE (220 ko)

Manual abstract: user guide TEXECOM PREMIER 412

Detailed instructions for use are in the User's Guide.

[. . . ] THANK YOU FOR VOTING TEXECOM MASTER USER MANUAL Security Control Panels with Integrated Communicator INS141-7 Contents Premier 412/816/832 Master User Manual Contents 1. 3 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 About this Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Fire Detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The selected partition(s) is now Away armed. " 8 If the Quick Arm feature is enabled, you can omit step 1 from the above procedure. INS141 Premier 412/816/832 Master User Manual Operating the Alarm System " To manually bypass zones, proceed as follows: Changing to another Partition Normally the remote keypad that you use will be assigned to a particular partition and therefore the zone and status lights will indicate information relevant to the assigned partition. However, you can temporarily switch the remote keypad to a different partition so that the zone and status lights indicate the information relevant to the partition that you have selected. Whilst in this mode you can also use your Access code to arm/disarm the partition you have selected (providing you have access to the selected partition). In order to use the cross partitioning feature, it is recommend that the system is configured as follows: · · · · Cross partitioning must be enabled. The user should be set for "Local Partition Access Only", see page 18. The remote keypads should only be assigned to a single partition. 1 1 2 3 Enter Access code ???? 4 Zones 5 6 7 8 Alarm Service Armed Ready YES to Arm?MENU for Options Bypass Zone> 00 *NONE BYPASSED* 2 1 2 3 4 Press B Zones 5 6 7 8 Alarm Service Armed Ready 3 1 2 3 The Ready light will flash quickly. Enter 02 to select Zone 2. 4 Zones 5 6 7 8 Alarm Service Armed Ready Bypass Zone> 02 Zone 02 Bypassed 4 5 The selected zone is now bypassed. Once the selected zones have been bypassed press: y/a to Away arm s to Stay arm N to return to the normal disarmed state " To change to another partition, proceed as follows: 1 1 2 3 4 Press A Zones 5 6 7 8 " If the Quick Bypass feature is enabled, you can omit step 1 from the above procedure. When one or more zones are bypassed the Ready light will flash and if the system is fitted with a Premier RKP8/16 Plus or LCD remote keypad then the Bypass light will also illuminate. Alarm Service Armed Ready AREA ARMED >. . . . Press 2 to select Partition 2. 4 Zones 5 6 7 8 Alarm Service Armed Ready Premier 816 17:35. 38 28/04 Unbypassing Zones To manually unbypass zones, perform the manual Bypass procedure on a zone that is already bypassed. · 24 hour zones cannot be unbypassed if they are still violated. If your installer has enabled the "Reinstate Bypassed Zones on Disarm" option, all zones will automatically be unbypassed each time the system is disarmed. The remote keypad will now indicate information relevant to the selected partition. " After changing to the selected partition, the remote keypad will only remain in the selected partition for 10 seconds after the last key press. However if an Access code is entered whilst the remote is in this mode, the remote keypad will remain in the selected partition for 1 minute after the last key press. · Bypassing Zones Manually Bypassing Zones Bypassing a zone prevents it from causing an alarm. " After manually bypassing a zone, the zone will remain bypassed until the zone is manually unbypassed. The Bypass menu will time-out if no key is pressed for 60 seconds. INS141 9 Operating the Alarm System Premier 412/816/832 Master User Manual " To Quick Bypass a group of zones and Away arm, proceed as follows: Group Bypass The Group Bypass feature allows you to bypass a predefined group of zones. " To bypass a group of zones, proceed as follows: 1 1 2 3 4 Enter bypass group 1 - 4 Zones 5 6 7 8 Alarm Service Armed Ready Premier 816 19:30. 56 28/04 1 1 2 3 Enter Access code ???? 4 2 1 Press a 2 3 4 Press y 8 Zones 5 6 7 Zones 5 6 7 8 Alarm Service Armed Ready YES to Arm?MENU for Options Bypass Zone> 00 Zone 03 Bypassed Bypass Zone> 00 Zone 04 Bypassed Alarm Service Armed Ready Please Exit. . . . 19:30. 56 28/04 2 Alarm Service Enter bypass group 1 - 4 followed by B 1 2 3 4 The Armed and Ready lights will flash and the exit tone will sound. Zones 5 6 7 8 Armed Ready 3 When the exit tone stops, the system is Away armed with the selected group of zones bypassed. 3 The keypad will display the bypassed zones. If required, zones can be added or removed from the group by entering the required zone number ??, e. g. Enter 05 to add Zone 5. 1 2 3 4 " To Quick Bypass a group of zones and Stay arm, proceed as follows: Zones 5 6 7 8 Alarm Service Armed Ready Bypass Zone> 05 Zone 03 Bypassed Bypass Zone> 05 Zone 04 Bypassed Bypass Zone> 05 Zone 05 Bypassed 1 1 2 3 4 Enter bypass group 1 - 4 Zones 5 6 7 8 Alarm Service Armed Ready Premier 816 19:30. 56 28/04 Premier 816 19:30. 56 28/04 2 1 2 3 4 Press s Zones 5 6 7 8 4 5 Alarm Armed Ready The selected zone is now bypassed. Once the selected zones have been bypassed press: y/a to Away arm s to Stay arm N to return to the normal disarmed state Service The alarm system will arm immediately and the Armed and Ready lights will flash. 3 The system is Stay armed with the selected group of zones bypassed. " If the Quick Bypass feature is enabled, you can omit step 1 from the above procedure. [. . . ] Revise the plan as conditions change, such as the number of people in the home, or if there are changes to the building's construction. 3. · 3. " · · · Household Fire Safety Audit Most fires occur in the home. To minimise the risk of fire, it is recommended that a household safety audit is conducted and a fire escape plan is developed. · Are all electrical appliances and outlets in a safe condition?If you are uncertain about the condition of your electrical appliances or household service, have a professional evaluate these units. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEXECOM PREMIER 412




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TEXECOM PREMIER 412 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.