User manual TEXECOM PREMIER 24

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TEXECOM PREMIER 24. We hope that this TEXECOM PREMIER 24 user guide will be useful to you.


TEXECOM PREMIER 24 : Download the complete user guide (242 Ko)

Manual abstract: user guide TEXECOM PREMIER 24

Detailed instructions for use are in the User's Guide.

[. . . ] Keypads will be installed throughout the premises, usually one at each entry/exit door. However, Local Users will only be able to use certain keypads on the system. The Emergency Keys In case of emergency, the alarm system can provide three immediate emergency alarms by pressing and holding two specific keys for two seconds. !" The emergency keys can be enabled/disabled for each keypad on the system. The Panic alarm can be programmed for either audible or silent operation. The Panic alarm can be programmed for either instant or delayed operation. Emergency Alarm Panic Alarm (PA) Fire Medical Press Keys !&" #&$ %&& The Quick Arm Keys The `Quick Arm' keys allow the system to be armed without having to enter a User code first. !" The `Quick Arm' keys will only work if the keypad has been programmed to allow arming in this way. To FULL arm the system, press '. [. . . ] Press * to arm normally or press - to arm silently The exit tone will sound (if silent arm has not been selected) 6. Leave the protected area When the system has armed, the exit tone (if sounding) will stop 4 INS221 Premier Series User Guide Operating the Alarm System To ARM Individual Areas If the system has been split up into separate areas of protection i. e. These areas can be individually selected for FULL or PART arming as required. !" Areas are selected by using keys !(the select an area followed by ' or +). / key can also be used to Only areas that exist on the system can be selected. (A `Star' means the area can be selected and a `Dot' means the area cannot be selected). Pressing 0 will select/deselect all areas, pressing ' will toggle between the first 8 areas and the second 8 areas (where applicable). Ensure that the premises are secure (all windows and doors not being omitted are closed) and the Ready light is on 2. Press )!, ( or " followed by * or - to PART arm the areas The exit tone will sound (if silent arm has not been selected) 6. Leave the premises When the system has armed, the exit tone (if sounding) will stop To DISARM the System The entry time is divided into two sections, the Entry time and the 2nd Entry time. If the Entry time expires, an Internal alarm will occur and the 2nd Entry time will start. If the 2nd Entry time expires, an Intruder alarm will occur (all internal and external sounders). !" It is perfectly normal for the 2nd Entry time to be programmed as zero, in which case, an Intruder alarm will occur as soon as the Entry time expires. 1. Enter the premises via the designated entry point The entry tone will start 2. Enter a valid User code , , , , The entry tone will stop INS221 5 Operating the Alarm System Premier Series User Guide To DISARM the System When Not in Entry 1. Press * To CANCEL the Exit Mode Once the exit mode has been started you should leave the premises immediately, however, if for some reason you decide not to leave, the exit mode must be cancelled. Press * The exit tone will stop. To CLEAR an Arm Fail When the system tries to arm with zones active (open), the internal sounders will sound and the external strobe will be flashing to indicate a problem. For details on preventing an Arm Fail condition, please refer to page 3. !" If you were not present when the Arm Fail occurred or you do not clear the Arm Fail, the internal sounders will continue to sound and the external strobe will continue to flash. 1. Enter a valid User code , , , , The internal and external sounders will stop, the external strobe will continue to flash and the number of the zone that caused the Arm Fail will be displayed. Enter a valid User code , , , , and press 12 To SILENCE an Alarm When an alarm occurs on the system, the internal and external sounders will normally sound for a pre-programmed time (normally 15 minutes). !" If you were not present when the alarm activated, the internal and external sounders may have already stopped but the external strobe will still be flashing. When alarm information is being displayed, pressing the SCROLL key will slow down the display and also allow manual scrolling through the events. 1. Enter a valid User code , , , , The internal and external sounders will stop and the number of the zone that caused the alarm will be displayed. [. . . ] The system can also be programmed to automatically turn chime on and off under certain conditions i. e. If no zones have been programmed for Chime, then turning Chime on and off will have no effect. To turn CHIME On 1. INS221 Premier Series User Guide Operating the Alarm System To CHANGE Your User Code Users with access to this option can change their own User codes. 3 * , , , , 4* (* , , , , * 1 INS221 10 Premier Series User Guide Installation Details 5. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEXECOM PREMIER 24




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TEXECOM PREMIER 24 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.