User manual TEKTONE NC205 NURSE CALL SYSTEM

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TEKTONE NC205 NURSE CALL SYSTEM. We hope that this TEKTONE NC205 NURSE CALL SYSTEM user guide will be useful to you.


TEKTONE NC205 NURSE CALL SYSTEM : Download the complete user guide (1132 Ko)

Manual abstract: user guide TEKTONE NC205 NURSE CALL SYSTEM

Detailed instructions for use are in the User's Guide.

[. . . ] 26 - 09/2002 Tek-DIGICARE® NC205 Nurse Call System UL® Listed 1069 INSTALLATION INSTRUCTIONS AND SERVICE MANUAL Website: www. tektone. net Email: tektone@tektone. net For Technical Assistance: 1-800-332-6608 Technical Assistance Email: teksupt@tektone. net 277 Industrial Park Road Franklin, NC 28734 (828) 524-9967 (800) 327-8466 Fax (828) 524-9968 4190 Fairview St. , Unit B-8 Burlington, ON L7L 4Y8 Canada (905) 333-0051 Fax (905) 333-0599 APPLICATION: The NC205 Tek-DIGICARE® Nurse Call System is a microcontroller based system consisting of central equipment cabinet(s) along with patient/duty/staff/emergency/code/presence stations, dome/zone lights, and master stations. The NC205 Series is designed for use in individual hospital wards, nursing homes, and congregate living centers. Copyright © TekTone Sound & Signal Mfg. , Inc. All Rights Reserved. Operation, Installation and Service Manual Copyright © 2002 TekTone® Sound & Signal Mfg. , Inc. , All rights reserved. No part of this publication may be copied without the express written permission of TekTone® Sound & Signal Mfg. , Inc. [. . . ] To reset the current call, the "RESET" button may be pressed, or the handset must be placed in its cradle­the user must wait for the new call to be registered before attempting to establish communications (do not attempt to use the hook switch to reset the call). Calls can also be answered by pressing the "TALK" button without first selecting a station. When used in this manner, the higher priority calls are answered first. Once these calls have been cleared, then the lower priority calls are answered next. NOTE: If a high or medium priority call is placed while a master station is in communication with another station, the "TALK" function with the current low priority call will only be active for 8-10 seconds; then the current call will be placed on hold, and the higher priority call will automatically reactivate the call tones at the appropriate rate. "TALK" must be pressed to connect audio; once the higher priority call is reset, the lower priority call can be answered again. To place a call, press the desired station selector button; then press the "TALK" button or pick up the handset. If pre-announce call tones are "ON", a one second tone will be heard at the master and room station when the station selector button is first pressed. Calls may be placed to patient, staff, or duty stations in the same manner. If a called station is in communications, a busy indication will be given by a flashing "TALK" LED. To place a call to another master, press the desired master selector button. The master receiving the "CALL" must have its own selector pushed before communication path will open. (All master to master communications are push to "TALK" only. ) NOTE: If a patient station is in privacy mode, no audio can be heard at the calling master from that station. To cancel a call, press the "RESET" button or hang up the handset. Medium, high priority, and personal attention calls must be reset at the point of origin. To upgrade calls in progress, press the "PRIORITY" button while the master is in communication with the station (see Section 4. 1-5C). If master stations are in communication, each can discontinue communications in order to respond to another station by pressing the "RESET" button. Incoming high or medium priority calls automatically cancel master-to-master communications after eight seconds. 4. 1-2 Staff Service Staff service functions are not available on IR250-IR253 and IR260A Standard Patient and Duty Stations. To request staff service, press the station selector button followed by the "STAFF" button; then press "RESET". To cancel a staff service request or staff presence, press the station selector button followed by the "STAFF" button; then press "RESET", or cancel at patient station by pushing the "RESET" button. Stations with staff requests pending will be indicated by the fast flashing of that station's selector button LED. [. . . ] YELLOW GREEN BLUE VIOLET GRAY WHITE BLACK : Standard Yellow ( Vf ~ 2. 0 ) : SPST momentary contact : Standard Red ( Vf ~ 2. 0 ) To enable code fault reporting the 2-pin CODE FAULT DISABLE on the same patient station. Refer to pin NAMES when connecting equipment!!!Observe all wire and NL205-H for maximum wiring distances and standard wire colors. NOTE: Fire indication at the nurse All wire numbers are minimum AWG sizes. Refer to NL205-HNC205 system is not intended for use as a fire alarm evacuation system. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTONE NC205 NURSE CALL SYSTEM




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTONE NC205 NURSE CALL SYSTEM will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.