User manual TASCAM LA-40MKIII

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TASCAM LA-40MKIII. We hope that this TASCAM LA-40MKIII user guide will be useful to you.


TASCAM LA-40MKIII : Download the complete user guide (1219 Ko)

Manual abstract: user guide TASCAM LA-40MKIII

Detailed instructions for use are in the User's Guide.

[. . . ] These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. CAUTION Changes or modifications to this equipment not expressly approved by TEAC CORPORATION for compliance could void the user's authority to operate this equipment. CE Marking Information a) Applicable electromagnetic environment: E4 b) Peak inrush current: 4. 2 A In North America use only on 120V supply. 2 TASCAM LA-40MKIII E_LA-40mkIII-OM_RevC. indd 2 08. 12. 19 1:03:23 PM IMPORTANT SAFETY INSTRUCTIONS 1 Read these instructions. [. . . ] 6 Front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Rear panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Bottom panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Level diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Example 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Example 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 4­Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 4 TASCAM LA-40MKIII E_LA-40mkIII-OM_RevC. indd 4 08. 12. 19 1:03:23 PM 1­Introduction Thank you very much for purchasing a TASCAM LA-40MKIII. Please read this Owner's Manual carefully and understand how to operate the device correctly before use. We hope that you will fully use the features of this unit for many years to come. After reading this manual, please keep it in a convenient place for future reference. Overview The LA-40MKIII has 4 internal circuits to convert unbalanced inputs to balanced outputs and 4 internal circuits to convert balanced inputs to unbalanced outputs. In addition, the Audio Distributed Amplifier (ADA) function allows single inputs to be assigned to multiple outputs using the INPUT LINK switches between each channel. for the entire unit · Each channel has an INPUT/OUTPUT LEVEL switch that allows input and output levels to be switched between -20 dBu and +4 dBu · Level indicator LEDs that show signal presence · Semi-fixed TRIM controls for fine level adjustment of ±12 dB · Rack mount brackets · Three-prong AC power outlet (Not on EUR model) · GND LIFT switches to turn the ground ON and OFF for each balanced connector · ALL LIFT switch that turns the ground ON and OFF Supplied accessories The following items are included with this product. · Main unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 · Power cord set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 · Rack mount screw set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 · Owner's Manual (this document) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 · Warranty card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Contact your TASCAM supplier if any of these items are missing. Precautions for placement and use · Use this unit within its operating temperature range of 5­40º C (40­104º F). In addition, please avoid placement in locations that are very dusty or humid because this could cause malfunction. This could cause damage to the internal circuitry or the case. NOTE Please be aware that, as a result of improvements or other changes to the product, photographs, illustrations and other depictions in the Owner's Manual may differ from the actual product. Cleaning the unit Use a soft cloth to wipe the unit clean. Do not clean it with chemical-based wipes, benzene, thinner, alcohol or similar substances. [. . . ] w Level indicator LED switch If this switch is ON, LEDs light when input signals are present. If this switch is OFF, the LEDs do not light regardless of the presence of input signals. e GND connector When multiple pieces of equipment are connected, use this to make the chassis of each piece of equipment have the same electrical potential. The GND LIFT switches do not cut the ground for the INPUTS 6. 6 TASCAM LA-40MKIII E_LA-40mkIII-OM_RevC. indd 6 08. 12. 19 1:03:23 PM 2­Names and Functions of Parts r Power outlet (see NOTE below) Use this three-prong outlet, which is not affected by the power switch, to connect AC equipment with a maximum power consumption of 400 W (or 3A). The specifications are displayed on the top of the unit. NOTE The EUR model does not have this power outlet, so the panel here is blank. t AC IN connector Connect the included power cord. Bottom panel y INPUT LEVEL switches 1­4 Switches that set whether the signal levels intput to the INPUTS 8 are +4 dBu (1. 23 V) or -20 dBu (0. 0775 V). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TASCAM LA-40MKIII




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TASCAM LA-40MKIII will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.