User manual TASCAM DA-30 MKII

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TASCAM DA-30 MKII. We hope that this TASCAM DA-30 MKII user guide will be useful to you.


TASCAM DA-30 MKII : Download the complete user guide (5558 Ko)

Manual abstract: user guide TASCAM DA-30 MKII

Detailed instructions for use are in the User's Guide.

[. . . ] Press DISPLAY to exit If no change is made, individual track delay values are retained. Press DISPLAY to exit Press DISPLAY to exit When ON this will mute all tracks not in Rec Ready when in shuttle mode. Press DISPLAY to exit Press DISPLAY to exit Press DISPLAY + to Exit or DISPLAY to go to Punch out point Press DISPLAY + to Exit Press DISPLAY + to Exit Use or to scroll through letters. Track Meters 1 & 2 show Block Error Rate in real time for playback heads A & B This enters the SY-88 Menu system This will exit SY-88 Menu system Allows front panel Record command on slave units. [. . . ] Once in the Menu System, pressing DISPLAY will scroll forward through the Menu Items. Holding DISPLAY and pressing will scroll back to the previous Menu items, Holding DISPLAY and pressing will exit the Menu system. Item No Display Choices Item Default Item Description Setting Default Dip Sw 1 Select DA-30 MKII Time Base Select operating Frame rate: 30 ndF, 29 ndF, 29 dF, 25 F and 24 F 2 t Display Only Displays Frame Rate of time code recorded on tape 3 t. out tc Abs ABS to TC conversion off on The following menus are available DA-30 MKII SYS Ver 3. 10 or later, and SY-88 Ver 4. 01 S1-#2 Must be in the down position for 9-pin control 4 ChS rEch FrEE Chase Mode rechase free S1 #3 5 vSync OFF on Video Sync Off On S1 #7 6 tCt. Record delay (See Manual) Record Delay See Manual for settings 10 trKArm. Track Mapping (See Table 3) Track Mapping See Table 3 for settings S3 #4&5 12 Shtmute 0 1 Shuttle Mute don't mute mute 13 FASt. 0 1 More Menu No Yes The following Menu items are available only when item 15, more is set to 1 16 v. LEAP 5F LTC mode leap 5 frames S1 #8 20 tCrEc 0 1 9-pin TC record enable Disable Enable 21 PSP. mute on Pgm Spd Play mode mute don't mute 22 rESEt Reset to factory defaults 23 rEAd Read current hardware switch settings Page 3 © TEAC America, Inc. , 1997 All rights reserved. DA-30 MKII quick ref. doc 10/14/97 7:27 PM SY-88 MENU FUNCTION Tables Page 4 © TEAC America, Inc. , 1997 All rights reserved. DA-30 MKII quick ref. doc 10/14/97 7:27 PM DA-30 MKII Power up sequences System version 3. 10 and up Hold the following keys in combination while powering on the DA-30 MKII. With ABS display selected, If and the number of cleaning cycles is displayed. POWER ON STOP VERSION RELEASE DATE D TIME DS TIME BOT STOP (at Beginning of Tape enter Stop mode) EOT STOP (at End of Tape enter Stop mode) SYS VERSION SY-88 VERSION PEAK HOLD ON (+ Clear to reset) PEAK HOLD OFF TEST MODE (when stop is pressed again) EOT REWIND (at End of Tape enter Rewind mode) SERVO VERSION BOT PLAY (at Beginning of tape enter Play mode) POWER ON PLAY are pressed again, Page 5 © TEAC America, Inc. , 1997 All rights reserved. DA-30 MKII quick ref. doc 10/14/97 7:27 PM DA-30 MKII ERROR NUMBERS AND THEIR DESCRIPTION ERROR S-Err-01 S-Err-02 DESCRIPTION Mechanical Problem (tape path, guide, drum motor, etc. ) Irregular head drum speed. The drum motor spin command is given, but no tachometer pulses from the frequency generator (FG) coil are received for 1. 5 seconds. Use of the dry cleaning tape will reduce the head life of the DA-30 MKII by approximately 5 hours for every cleaning cycle, use is therefor reserved for situations when playback errors occur and a manual cleaning is not possible. If you elect to use the dry cleaning tape, RUN ONE PASS ONLY NOT MULTIPLE CYCLES. If this does not resolve the situation, a manual cleaning or alignment is required. Note that the cleaning interval may be longer or shorter depending on your individual environmental conditions. (requires proper test and measurement equipment, and should be performed by qualified service personnel) During third cleaning, (1000 hours) a complete alignment check is suggested. Remember, the duration between cleanings may vary depending on your environment. Although most name brand tapes are of very high quality, it is possible to receive some "bad" stock. If you receive tape stock that sheds, immediately stop using it, and clean you transport. Page 7 © TEAC America, Inc. , 1997 All rights reserved. DA-30 MKII quick ref. doc 10/14/97 7:27 PM DA-30 MKII Digital Dubbing Requirements: 1 PW-88S Sync Cable 1 PW-88D Digital Dubbing Cable 1 RCA to RCA audio cable. (If dubbing Time code) 2 DA-30 MKIIs (Both must have SY-88 Sync cards if dubbing Time code) 1 Pre-Formatted tape. Procedure: 1) With power off, connect Source DA-30 MKII SYNC OUT to Target DA-30 MKII SYNC IN using the PW-88 Sync cable. [. . . ] 2) With Power off, connect Source DA-30 MKII DIGITAL I/O port to Target DIGITAL I/O port using the PW-88D Digital Dubbing cable. If dubbing Time code, connect TC Out from source DA-30 MKII to TC In on the target DA-30 MKII using the RCA to RCA audio cable. 3) Power On both DA-30 MKIIs 4) On the Source DA-30 MKII, enter a 43 Fs Track Delay value for all 8 tracks. c) If dubbing Time code, on Source DA-30 MKII set menu Item 6 to Digital (old S1 #5 Up). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TASCAM DA-30 MKII




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TASCAM DA-30 MKII will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.