User manual SYQUEST EZ230 EXTERNAL PARALLEL PORT
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SYQUEST EZ230 EXTERNAL PARALLEL PORT. We hope that this SYQUEST EZ230 EXTERNAL PARALLEL PORT user guide will be useful to you.
Manual abstract: user guide SYQUEST EZ230 EXTERNAL PARALLEL PORT
Detailed instructions for use are in the User's Guide.
[. . . ] If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, try to correct the interference by one or more of the following measures:
· · · ·
Reorient the antenna Relocate the equipment with respect to the receiver Move the equipment away from the receiver Plug the equipment into a different outlet so that equipment and receiver are on different branch circuits
If necessary, consult your dealer or an experienced radio/television technician for additional suggestions. The booklet entitled How to Identify and Resolve Radio-TV Interference Problems, prepared by the Federal Communications Commission, may be helpful. Government Printing Office, Washington, DC 20402.
Safety Standards
This product meets the following national and international regulations:
· UL 1950 Standard for Safety of Information Processing and
Business Equipment
· · · · · ·
UL Standard for Safety of Information Technology CSA C22. 2 No. 220 Information Processing Equipment IEC 435 Safety Requirements for Data Processing Equipment IEC 380 Safety of Electrical Energized Office Equipment IEC 950 Safety of Information Technology Equipment in Electrical Business Equipment
· VDE 0871/1984 · VFG 243/1991
Inquiries
While every effort has been made to ensure that the information provided herein is correct, please notify us in the event of any errors. [. . . ] Insert an EZFlyerTM 230MB cartridge into the drive.
The drive will begin to spin up the cartridge, and the Activity LED will flicker. See "Inserting the Cartridge" on page 10 for details.
6
EZFlyer 230 MB Removable Cartridge Hard Drive
Installing SyQuest® Software
After connecting your EZFlyerTM drive to your computer, you need to install SyQuest® software in order to use your drive. The DOS, Windows 3. 1, and Windows 95 installations include the SyQuest® drivers and the SyQuest® Utility software. The OS/2 and Windows NT installations include the SyQuest® drivers only.
DOS/Windows Users: 1. Exit Windows to DOS.
Press Alt + F4 to exit out of Windows; do not use a DOS shell.
2. Insert SyQuest® Installation Diskette-3 into your
diskette drive.
3. At a DOS prompt, type: A:INSTALL and press Enter.
If B: is your 3. 5-inch diskette drive, type B:INSTALL and press Enter.
Windows 95 Users: 1. In the Control Panel Window, double-click the
Add/Remove Programs icon.
3. Insert SyQuest Installation Diskette-2 into the diskette
drive and click Install.
4. Follow the instructions in the window at the bottom of
the screen to install the SyQuest driver
®
You may need to rearrange the program windows to view all windows.
6. The Activity LED will glow steadily green when the drive is ready.
10
EZFlyer 230 MB Removable Cartridge Hard Drive
Caution: If you drop your EZFlyerTM drive, Do not insert a cartridge or test your drive to see if it was damaged by the drop. Contact your SyQuest® reseller for instructions.
Installation Guide for PC Compatible Systems
11
Removing the Cartridge
Follow these steps to remove the cartridge when changing cartridges or transporting your EZFlyerTM drive.
1. Verify that the Power LED glows green.
The EZFlyerTM should always be switched on when you eject a cartridge.
2. Exit out of all applications that use the cartridge and
close all open files on the cartridge.
You may lose data if you eject the cartridge before closing all open files on the cartridge.
3. Windows 3. 1 Users: Double-click the SyQuest® Unlock Utility icon, select the EZFlyerTM drive letter and click Ok. Windows 95 Users: Windows 95 automatically locks and unlocks the cartridge. You do not need to manually unlock the cartridge to remove the cartridge. OS/2 Users: Select the EZFlyerTM drive icon, click the right mouse button, and select the Unlock menu item.
4. Press the Eject button on the front of the EZFlyerTM
drive.
The Drive Activity LED will flicker, the drive door will open, and the cartridge will pop out of the drive after a few seconds. If the Drive Activity LED does not flicker, unmount the cartridge using the SyQuest® Windows 95 Utility, or use the SyQuest® Unlock utility in Windows 3. 1.
12
EZFlyer 230 MB Removable Cartridge Hard Drive
5. Remove the cartridge and place it in its case.
Always store the cartridge in its protective case with the cardboard sleeve on.
Case Cartridge
B 0M 23
ID GE HA RD DR IV E
Sleeve
e fly ez
RE
MO
r
TM
VA
B
C LE
AR
TR
ezflye
R EM
O VA
r
BLE
TM
CAR
230
TRID
AR GE H
MB
IV D DR E
®
®
Note: Your protective case may not look exactly like the example shown here.
Caution: Never store or transport the EZFlyerTM with the cartridge partially inserted. Leaving a cartridge partially inserted, or transporting the EZFlyerTM with the cartridge inserted may damage the EZFlyerTM drive and void your warranty.
Installation Guide for PC Compatible Systems
13
Ejecting the Cartridge without Power
In the event of a power failure, you can remove the cartridge using the manual eject hole.
1. [. . . ] Windows 95 Users: From the Start button, select RUN, type A:SET135L, and press Enter. Note: If your 3. 5-inch diskette drive is drive B:, replace A: in the commands in step c above with B:.
2. Remove the existing Windows 95 EPP Driver
Only Windows 95 users should complete this step.
14
EZFlyer 230 MB Removable Cartridge Hard Drive
a. Click the SyQuest Parallel Port Device entry to select the old driver. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SYQUEST EZ230 EXTERNAL PARALLEL PORT
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SYQUEST EZ230 EXTERNAL PARALLEL PORT will begin.