User manual SYNQ AUDIO RESEARCH STAGE BEAMER RGB V1.0

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SYNQ AUDIO RESEARCH STAGE BEAMER RGB. We hope that this SYNQ AUDIO RESEARCH STAGE BEAMER RGB user guide will be useful to you.


SYNQ AUDIO RESEARCH STAGE BEAMER RGB V1.0: Download the complete user guide (3356 Ko)

Manual abstract: user guide SYNQ AUDIO RESEARCH STAGE BEAMER RGBV1.0

Detailed instructions for use are in the User's Guide.

[. . . ] 3. 4--ACTIVATING AUTO PROGRAMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10. 3. 5--RUN MODE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. 6--DMX512 SETTINGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11. 3. 7--PERSONALITY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] DO NOT stand close to the equipment and stare directly into the LED light source. Always make sure that the supporting structure is solid and can support the combined weight of the products. Do not touch the power cables if your hands are wet. ATTENTION This product left the place of manufacture in perfect condition. In order to maintain this condition and for safe operation, the user must always follow the instructions and safety warnings described in this user manual. Make sure that all parts of the equipment are kept clean and free of dust. Always make sure that the power connections are connected correct and secure. If there is any malfunction of the equipment, contact your distributor immediately. When transferring the product, it is advisable to use the original packaging in which the product left the factory. Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their effectiveness is impaired. The lamp (LED) shall be changed if it has become damaged or thermally deformed. 1 PRODUCT(GENERAL) 4 2009. 11. 10 2 INSTALLATION 2. 1 MOUNTING HANGING The fixture can be mounted in a hanging position using the supporting bracket. The bracket should be secured to the mounting truss or structure using a standard mounting clamp. Please note that when hanging the unit a safety cable should also be used. UPRIGHT The fixture can be mounted in an upright or sitting position using the supporting brackets. The LED MODULE can be mounted at any angle and in any position. It is possible to further adjust the angle of the LED MODULE using the two adjustment knobs located on the side of the fixture. 2. 2 POWER CONNECTIONS @ 220V: 24 units may be connected in series @120V: 12 units may be connected in series Note: If the signal cable is over 60m between the DMX512 controller and fixture or beween two fixtures, then a DMX signal amplifier is needed as well. 2 INSTALLATION 5 2009. 11. 10 2. 3 SETTING UP WITH A DMX512 CONTROLLER 2. 3-1 DMX512 ADDRESSING WITHOUT ID ADDRESSING (TOUR MODE) Connect the DMX512 controller to the units in series. Each unit has 10 DMX channels so the DMX Addresses should increase by increments of 10 (e. g. 1, 11, 21, 31. . . ) The ID address has not been set so therefore when using the controller CH 10 must be inactive ( CH10=0 ). It is also possible to deactivate ID address selecting ID OFF from the Settings menu. on the fixture Each DMX Address may be used as many times as required. Any DMX address in the range from 001 to 512 may be used. Example: The figure above shows a simple DMX512 layout with the starting address of the first unit set at 1, with the second set at 11and so on. . . (Note that when used in this way, the Ch10 ID function must be inactive (CH10=0)) 2. 3-2 DMX512 ADDRESSING WITH ID ADDRESS (TOUR MODE) Connect the DMX512 controller to the units in series Each unit has 10 DMX channels so the DMX Addresses should increase by increments of 10 (e. g. 1, 11, 21, 31. . . ) Each DMX Address may be used as many times as required. ID addresses are accessible from Ch10 on the DMX512 controller. 2 INSTALLATION 6 2009. 11. 10 Example: The figure above shows a simple DMX layout which has used three units at each DMX address. The three units have different ID addresses which allows the user to collectively control the whole group of units at that DMX address by setting CH10 to 0, or to control each unit independently by first selecting the DMX address and then by using Ch10 to locate the target ID address. 2 INSTALLATION 7 2009. 11. 10 3 DISPLAY PANEL OPERATION 3. 1 BASIC MENU ENTER scroll through the main menu or return to the main menu enter the currently selected menu or confirm the current function value scroll 'UP' through the menu list or increase the value of the current function scroll 'DOWN' through the menu list or decrease the value of the current function 3 DISPLAY PANEL OPERATION 8 2009. 11. 10 3. 2 MENU 3 DISPLAY PANEL OPERATION 9 2009. 11. 10 3. 3 EDIT STATIC COLOUR STATIC COLOUR Combine Red , Green & Blue to create an infinite range of colors (0-255) Set the value of the Strobe (0-20Hz) 3. 4 ACTIVATING AUTO PROGRAMS AUTO Select the target AUTO program and press ENTER . [. . . ] When the new setting is activated, the DMX controller choose RGB = 255, 255, 255, the white color will be made by the actual RGB values on the CAL2 . 3. 13 ACTIVATE THE PASSWORD KEY Enter the KEY mode to select whether the access password is on or off. When the fixture is set as PASS ON , after 30 seconds or turn on the fixture next time, the fixture will need an access password to enter the display menu control. Note: The factory access password is UP + DOWN then press ENTER to confirm the access. + UP + DOWN , 3 DISPLAY PANEL OPERATION 13 2009. 11. 10 4 USING A DMX512 CONTROLLER 4. 1 BASIC ADDRESSING Connect all of the units in series using standard DMX512 signal cable or the IP65 rated cable provided. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SYNQ AUDIO RESEARCH STAGE BEAMER RGB




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SYNQ AUDIO RESEARCH STAGE BEAMER RGB will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.