User manual SYNQ AUDIO RESEARCH LED MINI PAR V2.1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SYNQ AUDIO RESEARCH LED MINI PAR. We hope that this SYNQ AUDIO RESEARCH LED MINI PAR user guide will be useful to you.


SYNQ AUDIO RESEARCH LED MINI PAR V2.1: Download the complete user guide (3400 Ko)

Manual abstract: user guide SYNQ AUDIO RESEARCH LED MINI PARV2.1

Detailed instructions for use are in the User's Guide.

[. . . ] 3. 4--AUTO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10. 3. 5--ADDRESS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10. 3. 6--RUN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10. 3. 7--PERSON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1. [. . . ] This product can also be installed for use in signage and advertising using the dynamic functions available with DMX512 control. Direct input of DMX512 signal allows the units to be controlled from any DMX512 controller. This product can be operated as a single unit or in multiple units for large applications. The specially developed controller that allows the product to be controlled independent of the DMX512 controller enables the user to create and edit a wide range of custom programs. All programs can be touch-button displayed or scheduled to START and END at scheduled times. When programs have been created or edited in the controller, it is also possible to trigger these programs using the DMX IN function when connected to a DMX512 controller. 1. 2 PRODUCT FEATURES LED FIXTURE * RGB Dimmer 0-100% * Strobe * Automatic programs * LCD display * Display control 'lock-out' * Direct DMX512 input * Independant ID address * Stand-alone/ Slave 1 PRODUCT(GENERAL) 1 2009. 12. 9 1. 3 TECHNICAL SPECIFICATIONS LED MODULE LED MODULE: Voltage Rated Power LED/Unit Output/LED 100~240V. . . 50/60Hz 30W 18pcs (6 x RED / 6 x GREEN / 6 x BLUE) 1W ~40 Environment Temperature -20 Cooling Dimensions Weight Forced air convection 240 x 210 x160mm 2. 5Kg 1 PRODUCT(GENERAL) 2 2009. 12. 9 1. 4 PHOTOMETRIC DATA PHOTOMETRIC DATA 1 PRODUCT(GENERAL) 3 2009. 12. 9 1. 5 SAFETY WARNING IMPORTANT ALWAYS READ THE USER MANUAL BEFORE OPERATION. PLEASE CONFIRM THAT THE POWER SUPPLY STATED ON THE PRODUCT IS THE SAME AS THE MAINS POWER SUPPLY IN YOUR AREA. A minimum distance of 0. 5m must be maintained between the equipment and combustible surface. DO NOT stand close to the equipment and stare directly into the LED light source. Always make sure that the supporting structure is solid and can support the combined weight of the products. Do not touch the power cables if your hands are wet. ATTENTION This product left the place of manufacture in perfect condition. In order to maintain this condition and for safe operation, the user must always follow the instructions and safety warnings described in this user manual. Make sure that all parts of the equipment are kept clean and free of dust. Always make sure that the power connections are connected correct and secure. If there is any malfunction of the equipment, contact your distributor immediately. When transferring the product, it is advisable to use the original packaging in which the product left the factory. Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their effectiveness is impaired. The lamp (LED) shall be changed if it has become damaged or thermally deformed. 1 PRODUCT(GENERAL) 4 2009. 12. 9 2 2. 1 INSTALLATION MOUNTING HANGING The LED PAR can be mounted in a hanging position using the supporting bracket. The bracket should be secured to the mounting truss or structure using a standard mounting clamp. Please note that when hanging the unit a safety cable should also be used. UPRIGHT The LED PAR can be mounted in an upright or sitting position using the supporting brackets. The LED MODULE can be moun ted at any angle and in any position. [. . . ] When [UC] is selected, the RGB output are adjusted to a standard preset universal color which balances fixtures from different generations. . The factory default setting is [UC] on. 3. 12 PASSWORD PASSWORD Enter the PASSWORD mode to select whether the access password is on or off. When the fixture is set as PASS ON , after 30 seconds or turn on the fixture next time, the fixture will need an access password to enter the display menu control. Note: The factory access password is UP + DOWN press ENTER to confirm the access. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SYNQ AUDIO RESEARCH LED MINI PAR




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SYNQ AUDIO RESEARCH LED MINI PAR will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.