User manual SYLVANIA T8 347V DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SYLVANIA T8 347V. We hope that this SYLVANIA T8 347V user guide will be useful to you.


SYLVANIA T8 347V DATASHEET: Download the complete user guide (651 Ko)

Manual abstract: user guide SYLVANIA T8 347VDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] www. sylvania. com QUICKTRONIC® T8 Instant Start 347 Volt ­ Canada Normal, Low & High Ballast Factor Standard & Professional Series Lamp / Ballast Guide 32W T8 - OCTRON 1-lamp QTP1x32T8/347 ISN-SC 2-lamp QTP2x32T8/347 ISN-SC 3-lamp QTP3x32T8/347 ISN-SC 4-lamp QTP4x32T8/347 ISN-SC ® SYLVANIA QUICKTRONIC 32IS-SC operates OCTRON T8 lamps with maximum efficacy and provides 30-40% energy savings when compared to F40T12 magnetic systems. [. . . ] Insulate to 600 volts. FO96T8/XP QT2x59 IS FO96T8/XP/SS QT2x59 IS QUICKTRONIC 2x59 SPECIFICATION DATA Catalog # Project Comments Date Prepared by Type Normal, Low, High BF T8 Instant Start 347V Standard & Professional Performance Guide Data shown based upon SYLVANIA OCTRON® FO32/XP® & FO96 T8 XP Lamp(s). QUICKTRONIC® ballasts are also compatible with other lamp manufacturers' equivalent lamp types that meet ANSI specifications. Input Power (W) System Efficacy (lm/W) BEF1 Electronic T8 Fluorescent Systems 347V Item Number OSRAM SYLVANIA Description Input Current (AMPS) Lamp Type Rated Lumens (lm) No. of Lamps Ballast Factor System (BF) Lumens Mean Lumens QUICKTRONIC® Low Ballast Factor (0. 77) <20% THD 49241 49939 QT2x32T8/347 ISL-SC QT4x32T8/347 ISL-SC 0. 15 0. 28 FO32/XP FO32/XP 3000 3000 2 4 0. 77 0. 77 4620 9240 4345 8685 51 98 91 94 1. 51 0. 79 QUICKTRONIC® PROFESSIONAL Normal Ballast Factor (0. 88) <10% THD 49711 49713 QTP1x32T8/347 ISN-SC QTP2x32T8/347 ISN-SC 0. 089 0. 165 0. 25 0. 33 FO32/XP FO32/XP FO32/XP FO32/XP 3000 3000 3000 3000 1 2 3 4 0. 88 0. 88 0. 88 0. 88 2640 5280 7920 10, 560 2480 4965 7445 9925 31 59 86 112 90 89 92 94 2. 84 1. 49 1. 02 0. 78 Specifications Starting Method: Instant Start Ballast Factor: 0. 77, 0. 88 & 1. 20 Circuit Type: Parallel Lamp Frequency: All SC models >40kHz Standard enclosure >20kHz Lamp CCF: Less than 1. 7 Starting Temp:3 QTP models: -20°F (-29°C) for OCTRON T8 lamps QT models: 0°F (-18°C) for OCTRON T8 lamps 60°F (16°C) for SUPERSAVER® T8 lamps 0°F (-18°C) for FO40T8 Input Frequency: 60 Hz THD: QTP <10%, QT <20% Power Factor: >97% Voltage Range: ±10% of Rated Input UL Listed Class P, Type 1 Outdoor CSA Certified 70°C Max Case Temperature FCC 47 CFR Part 18 Non-Consumer Class A Sound Rating ANSI 62. 41 Cat. A Transient Protection GFCI compatible Emergency ballast compatible Remote Mounting (Max. wire length from ballast case to lampholder): · 20 ft: full wattage T8s · 10 ft: energy saving T8s · 4 ft: 25W energy saving T8s 3 Operation below 50°F (10°C) may affect light output or lamp operation ­ see "Low Temp. Starting" definition. NEW! 49715 QTP3x32T8/347 ISN-SC 49716 Pallet Pack 49717 QTP4x32T8/347 ISN-SC 49718 Pallet Pack QUICKTRONIC® High Ballast Factor (1. 20) <20% THD 49927 QT2x32T8/347 ISH-SC 2 0. 23 FO32/XP 3000 2 1. 2 7200 6770 78 92 1. 54 QUICKTRONIC 59T8 (8 Foot) Normal Ballast Factor (0. 88) <20% THD 49217 QT2x59/347 IS 0. 33 FO96T8 XP(59W) 6100 2 0. 88 10, 735 10, 090 110 98 0. 80 Products above are 10-pack unless noted. Pallet Pack contains 840 pieces, (add "-PAL" to Description). 1: Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power. [. . . ] (approx. ) 8. 70 mm Slot Width 49713 QTP 2 x 32T8 / 347 ISN - SC Case Size Starting/Ballast Factor Line Voltage Primary Lamp Wattage Specifications subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SYLVANIA T8 347V




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SYLVANIA T8 347V will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.