QUICKTRONIC® T8 8' Instant Start Universal Voltage
Normal Ballast Factor Professional Series
Lamp/Ballast Guide
59W T8 8-Foot - OCTRON 2-lamp QTP2x59T8 UNV ISN SC
®
SYLVANIA QUICKTRONIC SYSTEM 59 ISN UNV electronic T8 ballasts offer several advantages: 1. [. . . ] QUICKTRONIC® 59 ISNSC is also compatible with other lamp manufacturers equivalent lamp types that meet ANSI specifications. Complete performance data is available in the QUICKSYSTEMS section of the SYLVANIA Electronic Ballast Catalog.
Electronic T8 8-foot Fluorescent Systems Universal Voltage (120-277V)
Item Number OSRAM SYLVANIA Description QTP 2x59T8/UNV ISN-SC 49590
49598 49599 Banded Pack 10-Pack Pallet Pack
Input Current (AMPS)
Lamp Type
Rated Ballast Input System Lumens No. of Factor System Mean Power Efficacy (lm) Lamps (BF) Lumens Lumens (W) (lm/W) BEF1 5700 6100 5700 4650 2850 6100 5700 4650 2850 2 2 2 2 2 1 1 1 1 0. 88 0. 88 0. 88 0. 89 0. 89 1. 02 1. 02 1. 02 1. 03 10, 030 10, 735 10, 030 8275 5075 6220 5815 4745 2935 9030 112/110 10, 090 112/110 9430 104/102 7780 86/85 4770 58 5850 67 5465 62 4460 51 2760 36 90/91 96/98 96/98 96/97 88 93 94 93 82 0. 80 0. 80 0. 86 1. 05 1. 53 1. 52 1. 65 2. 00 2. 86
0. 93/0. 40 FO96T8/700 (59W) 0. 93/0. 40 FO96T8/XP (59W) 0. 85/0. 36 FO96T8/XP/SS (55W) 0. 70/0. 31 FO72T8/XP 0. 47/0. 21 FO48T8/XP 0. 56/0. 25 FO96T8/XP (59W) 0. 51/0. 22 FO96T8/XP/SS (55W) 0. 43/0. 20 FO72T8/XP 0. 30/0. 14 FO48T8/XP
Specifications Data based on FO96T8
Starting Method: Instant Start Ballast Factor: 0. 88 Circuit Type: Parallel Lamp Frequency: >40kHz Lamp CCF: Less than 1. 7 Starting Temp:2 0°F (-18°C) for OCTRON® 96T8 lamps 60°F (16°C) for SUPERSAVER® lamps Input Frequency: 50/60Hz Low THD: <10% Power Factor: >98% Voltage Range: ±10% of 120-277V rated line (108-305V) UL Listed Class P, Type 1 Outdoor CSA Certified 70°C Max Case Temperature FCC 47CFR Part 18 Non-Consumer Class A Sound Rating ANSI C62. 41 Cat A. Transient Protection GFCI compatible Emergency ballast compatible Remote Mounting (Max. wire length from ballast case to lampholder): · 20 ft: full wattage T8s · 10 ft: energy saving T8s
2 Operation below 50ºF (10°C) may affect light output or lamp operation see "Low Temp. Starting" definition.
Banded Pack, (add "-B" to Description). [. . . ] OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www. sylvania. com 43
Item Number QUICKTRONIC PROFESSIONAL Number of Lamps
49598 QTP 2 x 59T8 / UNV ISN SC
Case Size Starting/Ballast Factor Line Voltage (120-277V)
Primary Lamp Type (59W FO96T8)
Specifications subject to change without notice. [. . . ]