User manual SYLVANIA QHE T8 PSH DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SYLVANIA QHE T8 PSH. We hope that this SYLVANIA QHE T8 PSH user guide will be useful to you.


SYLVANIA QHE T8 PSH DATASHEET: Download the complete user guide (558 Ko)

Manual abstract: user guide SYLVANIA QHE T8 PSHDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] www. sylvania. com QUICKTRONIC® PROStart® T8 High Ambient Temperature High Efficiency Series Type CC, Lamp Striation Control & Parallel Operation High Ballast Factor Q HE T8 PSH Lamp / Ballast Guide Primary Systems 32W T8 - OCTRON® 2-lamp QHE2x32T8/UNV PSH-HT 3-lamp QHE3x32T8/UNV PSH-HT 4-lamp QHE4x32T8/UNV PSH-HT Also operates: FBO32, FBO31, FO30/SS (30W), FO28/SS (28W), FO25/SS (25W), FBO30/SS (30W), FBO29/SS (29W), FO25, FBO24, FO17 & FBO16 Key System Features · High Efficiency Systems over 90% efficient · NEMA Premium Ballast compliant · PROStart Programmed Rapid Start · Extends lamp life · High ballast factor: 1. 15 · Parallel operation, (one lamp out, remaining lamps stay lit) · 90°C maximum case temp. [. . . ] Lamp Striation Control (LSC): T8 energy saving lamps should be operated above 60°F, but under certain conditions the lamps may striate. LSC circuitry may minimize or eliminate this condition; however there are limited applications where LSC circuitry may not entirely mitigate lamp striations. (Please consult lamp manufacturers for additional details. ) % Lamp Life @3hrs/ start Baseline 60% 180% System Information SYLVANIA QUICKTRONIC High Efficiency (QHE) System advantages: · Operate from 120V through 277V · Eliminates "wrong voltage" errors · Reduces inventory by 50% · Utilizes Programmed Rapid Start operation for: · Highest System Efficacy · Longer Life · Over 100, 000 switching cycles for occupancy sensor and building control systems applications. · Operate at >42Hz to reduce potential interference with infrared control systems Lamp & Ballast Type M400/U Magnetic Ballast 3-F96T12HO Magnetic Ballast 6-FO32/800/XPS 2-QHE3x32 PSH Input Power (W) 452 360 220 Initial LPW 61 58 83 Mean Fixture* Lumens 17, 784 16, 875 17, 090 Relative Fixture* Output Baseline 95% 96% % Energy Savings Baseline 20% 51% *Based on Fixture Efficiency: 76% for M400/U and 85% for T12HO and FO32T8 lamps. 200% 180% 160% 140% 120% 100% 100% 100% 100% 80% 60% 40% 20% 0% M400/U Mag. Ballast 6-FO32/800/XPS 2-QHE3x32 PSH 95% 80% 60% 49% Application Information SYLVANIA QUICKTRONIC PROStart T8 is ideally suited for: · High bay · Warehouses · Applications where extended lamp life is required to reduce maintenance costs · Areas where frequent switching is desired · Occupancy sensor usage · Building control systems · Areas that are underlit 38 % Relative Fixture* Light Output % System Wattage % Lamp Life 180% 20% Energy Savings 51% Energy Savings 96% SPECIFICATION DATA Catalog # Project Comments Date Prepared by Type High Ballast Factor T8 PROStart Input Power (W) 72/70 72/70 69/67 63/62 56/55 55 38 System Efficacy (lm/W) 89/92 96/99 95/98 100/101 102/104 92 85 ® PSH High Efficiency Performance Guide Data based upon SYLVANIA OCTRON® lamps shown. QUICKTRONIC® QHE PROStart ballasts are also compatible with other lamp manufacturers equivalent lamp types that meet ANSI specifications. QHE PROStart ballasts will also operate F17 & F25, SUPERSAVER & U-Bend equivalent T8 lamps. High Efficiency Type CC, Lamp Striation Control & High Ambient (120-277V) Item Number 49450 49459 OSRAM SYLVANIA Description QHE2x32T8/UNV-PSH-HT Banded Pack Pallet Pack Input Current (AMPS) Lamp Type Rated Ballast Lumens No. of Factor System Mean (lm) Lamps (BF) Lumens Lumens 2800 3000 2850 2725 2475 2175 1375 2800 3000 2850 2725 2475 2175 1375 2800 3000 2850 2725 2475 2175 1375 2 2 2 2 2 2 2 3 3 3 3 3 3 3 4 4 4 4 4 4 4 1. 15 1. 15 1. 15 1. 15 1. 15 1. 16 1. 17 1. 15 1. 15 1. 15 1. 15 1. 15 1. 17 1. 18 1. 15 1. 15 1. 15 1. 15 1. 15 1. 17 1. 18 6440 6900 6555 6270 5695 5045 3220 9660 10, 350 9835 9400 8540 7635 4870 12, 880 13, 800 13, 110 12, 535 11, 385 10, 180 6490 5795 6485 6160 5890 5350 4740 3025 8695 9730 9245 8835 8025 7175 4575 11, 590 12, 970 12, 325 11, 785 10, 700 9570 6100 BEF 1 1. 64 1. 64 1. 72 1. 85 2. 09 2. 11 3. 08 1. 06 1. 06 1. 14 1. 24 1. 37 1. 43 2. 11 0. 82 0. 82 0. 88 0. 93 1. 05 1. 10 1. 62 NEW! 0. 60/0. 27 FO32/700 0. 60/0. 27 FO32/XP 0. 57/0. 25 FO30/SS 0. 53/0. 23 FO28/SS 0. 47/0. 20 FO25/SS 0. 46/0. 20 FO25/XP 0. 32/0. 14 FO17/XP 0. 94/0. 40 FO32/700 0. 94/0. 40 FO32/XP 0. 88/0. 37 FO30/SS 0. 81/0. 34 FO28/SS 0. 72/0. 31 FO25/SS 0. 70/0. 30 FO25/XP 0. 48/0. 21 FO17/XP 1. 22/0. 53 FO32/700 1. 22/0. 53 FO32/XP 1. 13/0. 49 FO30/SS 1. 06/0. 46 FO28/SS 0. 95/0. 41 FO25/SS 0. 91/0. 40 FO25/XP 0. 63/0. 28 FO17/XP Q HE T8 PSH QHE3x32T8/UNV-PSH-HT 49453 49460 Banded Pack Pallet Pack 110/108 88/89 110/108 94/96 104/101 95/97 95/93 99/101 85/84 100/102 83/82 92/93 56 87 143/141 90/91 143/141 97/98 132/130 99/101 124/123 101/102 112/110 102/104 107/106 95/96 73 89 Specifications Data based on F32T8 Starting Method: Programmed Rapid-Start Ballast Factor: 1. 15 Circuit Type: Parallel Lamp Frequency: >40 kHz Lamp CCF: Less than 1. 7 Starting Temp:2 0°F (-18°C) for OCTRON T8 lamps; 60°F (16°C) for SUPERSAVER® T8 lamps Input Frequency: 50/60 Hz THD: <10% Power Factor: >98% Voltage Range: ±10% of 120-277V rated line (108-305V) UL Listed Class P, Type 1 Outdoor UL Type CC Rated Lamp Striation Control (LSC) CSA Certified High Ambient Applications: 90°C Max. [. . . ] Rating Starting Type/Ballast Factor Line Voltage (120-277V) OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www. sylvania. com 39 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SYLVANIA QHE T8 PSH




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SYLVANIA QHE T8 PSH will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.