User manual SYLVANIA 2820LV

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SYLVANIA 2820LV. We hope that this SYLVANIA 2820LV user guide will be useful to you.


SYLVANIA 2820LV : Download the complete user guide (10105 Ko)

Manual abstract: user guide SYLVANIA 2820LV

Detailed instructions for use are in the User's Guide.

[. . . ] The communications protocol is "DALI", an acronym for "Digital Addressable Lighting Interface". This is a worldwide standard for digital lighting control that has been accepted by all the leading lighting suppliers. [. . . ] SYSTEM 32 DALI controls OCTRON T8 lamps over a wide (100-1%) range of light level settings, from 1. 0 ballast factor to . 01 ballast factor. Control wiring is simplified by two polarity-free connections that can be routed in the same raceway as power wires. SYSTEM 32 DALI is available in one and two lamp models that operate at 120V or 277V input line voltage, eliminating "wrong voltage" wiring errors and reducing the number of models in inventory by half. 2820LV SYSTEM 32 DALI offers full rated lamp output (1. 0 ballast factor) at the maximum light setting. Compared to "normal" systems (0. 88 ballast factor), this allows for higher light levels when desired and can be used to compensate for lamp lumen depreciation. Setting the standard for quality, SYSTEM 32 DALI is also covered by our QUICK 60+® warranty, the first and most comprehensive system warranty in the industry. System Information Programmed rapid start ballasts provide optimum starting conditions to provide up to 100, 000 switching cycles for use on occupancy sensor and building control system applications. QUICKTRONIC® DALI ballasts are also compatible with other manufacturers equivalent lamp types that meet ANSI specifications. Input Power (Watts) 36 6 72/70 12 Electronic DALI T8 Fluorescent Controllable Lighting Systems (120/277V) Item Number 51350 51352 Input Current (AMPS) 0. 31/0. 13 0. 61/0. 26 Lamp Type FO32XP FO32XP Rated Lumens (lm) 3000 3000 No. of Lamps 1 2 Ballast Factor (BF) 1. 00 0. 01 1. 00 0. 01 System Lumens 3000 30 6000 60 Description QTP 1x32T8/UNV DALI QTP 2x32T8/UNV DALI BEF1 2. 78 1. 43 Specifications Starting Method: Programmed Rapid Start Circuit Type: Series Lamp Frequency: >40kHz Lamp CCF: <1. 7 Starting Temp: 50°F (10°C) min. Input Frequency: 50/60 Hz THD: <10% @ full output Power Factor: >98% @ full output Voltage Range: ±10% of 120/277 rated voltage UL Listed Class P, Indoor cUL Certified Temp. Test Point (Tc) on ballast label: 1 lamp model: 65°C max 2 lamp model: 70°C max. [. . . ] Test Point (Tc) on ballast label: 1 lamp model: 65°C max 2 lamp model: 70°C max. A Transient Protection No Remote or Tandem Wiring 1: Ballast Efficiency Factor (BEF) = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). Wiring Diagrams: Wiring: Push-in (wiretrap) connections Use 18 AWG solid copper wire only LAMP Green White Black Purple Purple G N L 1 2 3 4 DALI DIMMING BALLAST Red Red Blue Blue 2820LV DALI Control Leads (non-polarized) Class 1 or Class 2 Circuit QTP1x32T8/UNV DALI LAMP 2 LAMP 1 Green White Black Purple Purple G N L 1 2 3 4 5 6 DALI DIMMING BALLAST Red Red Yellow Yellow Blue Blue DALI Control Leads (non-polarized) Class 1 or Class 2 Circuit Control Information QUICKTRONIC DALI ballasts are compatible with DALI digital controllers available from various manufacturers. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SYLVANIA 2820LV




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SYLVANIA 2820LV will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.