User manual SUB-ZERO WOLF WARMING DRAWER INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO WOLF WARMING DRAWER. We hope that this SUB-ZERO WOLF WARMING DRAWER user guide will be useful to you.


SUB-ZERO WOLF WARMING DRAWER INSTALLATION: Download the complete user guide (181 Ko)

Manual abstract: user guide SUB-ZERO WOLF WARMING DRAWERINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] Refer to the illustration below. RATING PLATE Location of rating plate. Installation Considerations 4 Installation Considerations · The warming drawer must be installed with a Wolf stainless steel or integrated drawer front. Make sure you have the accessory drawer front called for in your installation. Specific installation instructions are included with the drawer front. · For all installations, the warming drawer must be fully enclosed, top and bottom. [. . . ] · The warming drawer may be installed next to or above another Wolf warming drawer. · Model WWD30O may be installed below a Wolf outdoor grill. Electrical Requirements The electrical supply should be located as shown in the illustration for your specific installation on the following pages. A separate circuit, servicing only this appliance is required. IMPORTANT NOTE: You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. If two warming drawers are installed side by side, they can operate from the same electrical outlet. A 30 amp circuit breaker is required for this installation. IMPORTANT NOTE: When installed outdoors, a ground fault circuit interrupter (GFCI) is required to reduce the risk of electrical shock. Electrical Requirements Power Supply Circuit Breaker Receptacle 120 V AC, 50/60 Hz 15 or 20 amp 3-prong grounding-type Installation Considerations 6 Drawer Front Options IMPORTANT NOTE: The warming drawer must be installed with a Wolf stainless steel or integrated drawer front. OVERALL DIMENSIONS A Wolf stainless steel and integrated drawer fronts allow for many design options, but the warming drawer itself will be the same for all applications. When installing a Wolf warming drawer in combination with an L series or E series built-in oven, you may choose the stainless steel drawer front to match the trim and handle of your oven. The E series 2" (51) thick drawer front with pro handle, in 30" (762) and 36" (914) widths, is designed to be installed below a sealed burner rangetop or outdoor gas grill, so the panel aligns properly with the front of the rangetop or grill. Keep in mind, overall dimensions for the warming drawer remain the same, even though the drawer front may be wider to match a Wolf 36" (914) wide oven, sealed burner rangetop or outdoor grill. 29 7/8" (759) OR 35 7/8" (911) 28 1/4" (718) 10 3/8" (264) 3/4" (19) 9" (229) B 3/4" (19) 22 3/4" (578) 211/2" (546) B Stainless Steel Drawer Front L SERIES Tubular Handle E SERIES 7/8" A (22) A B 3 1/2" (89) B Tubular Handle Pro Handle Pro Handle (2" thick) 11/8" (29) 11/8" (29) 2 1/8" (54) 3 1/2" (89) 3 1/2" (89) 4 1/2" (114) Dimensions may vary ± 1/8" (3). Integrated Drawer Front CUSTOM PANEL W H Typical 29 7/8" (759) 10 3/8" (264) 3/4" D (19) Installation Considerations 7 wolfappliance. com/specs Installation Options STANDARD, RECESSED OR FLUSH INSET INSTALLATION The warming drawer with E series drawer front can be installed in a standard, recessed or flush inset application. For a standard installation, the drawer collar and front panel sit proud of the cabinet face frame. A recessed installation requires the cabinetry be recessed by 3/16" (5) so the collar is flush with the cabinet face frame but the drawer front will sit proud. A flush inset installation requires the drawer collar and front panel be recessed to be flush with surrounding cabinetry. Refer to illustrations on the following pages for minimum cabinet dimensions for your specific installation. Mounting holes will need to be drilled in the back of the drawer front panel. Holes should be drilled on site to ensure proper fit and gaps are achieved. A drilling template is provide with the integrated drawer front. IMPORTANT NOTE: Be sure to finish the inside lip of the opening and the front face of the platform and cleats. IMPORTANT NOTE: Be aware of the location of the mounting holes on the warming drawer frame to make sure screws used to attach the cleats do not interfere with screw holes for mounting the warming drawer. INSTALL RECESSED CLEATS AND PLATFORM For a recessed or flush inset application, you will need to install a recessed platform and cleats into the opening. Proper recess of the platform and cleats is critical to the function and esthetics of the warming drawer installation. Be sure to rigidly mount the platform so that it can support a minimum of 200 lbs (91 kg). Refer to the illustrations below. TOP CLEAT TOP CLEAT PLATFORM SIDE CLEAT PLATFORM SIDE CLEAT CLEATS AND PLATFORM RECESSED 3/16" (5) CABINETRY OPENING CLEATS AND PLATFORM RECESSED 3/16" (5) PLUS THICKNESS CABINETRY OF DECORATIVE PANEL OPENING Recessed application. Flush inset application. Warming Drawer Specifications 8 Standard Installation L SERIES, E SERIES OR INTEGRATED DRAWER FRONT DIMENSION WILL VARY* ANTI-TIP BLOCK 91/8" (232) OPENING HEIGHT 10 3/8" (264) 28 5/8" (727) OPENING WIDTH PLATFORM E 36" (914) 24" (610) min CABINET DEPTH FLOOR TO COUNTERTOP 23 1/2" (597) TYPICAL SIDE VIEW FRONT VIEW *Dimension must accommodate height of anti-tip block and drawer face overlap. NOTE: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. Warming Drawer Specifications 9 wolfappliance. com/specs Flush Inset Installation E SERIES OR INTEGRATED DRAWER FRONT TOP VIEW 1" (25) 24 (610) min FLUSH INSET DEPTH SIDE CLEATS ANTI-TIP BLOCK DIMENSION WILL VARY* 91/8" (232) OPENING HEIGHT 10 7/8" (276) FLUSH INSET HEIGHT 7/8" (22) TOP AND SIDE CLEATS 28 5/8" (727) OPENING WIDTH 7/8" (22) PLATFORM E E 36" (914) 24" (610) min CABINET DEPTH FLOOR TO COUNTERTOP 23 1/2" (597) TYPICAL 30 3/8" (772) FLUSH INSET WIDTH SIDE VIEW FRONT VIEW *Dimension must accommodate height of anti-tip block and drawer face overlap. [. . . ] · Check electrical connections to ensure that the installation has been completed correctly. · Refer to the troubleshooting guide in the Wolf warming drawers use & care guide. · If the warming drawer still does not operate properly, contact a Wolf authorized service center. Wolf is not responsible for service required to correct a faulty installation. RATING PLATE Location of rating plate. The information and images in this guide are the copyright property of Wolf Appliance, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO WOLF WARMING DRAWER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO WOLF WARMING DRAWER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.