User manual SUB-ZERO WARMINGDRAWER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO WARMINGDRAWER. We hope that this SUB-ZERO WARMINGDRAWER user guide will be useful to you.


SUB-ZERO WARMINGDRAWER : Download the complete user guide (258 Ko)

You may also download the following manuals related to this product:

   SUB-ZERO WARMINGDRAWER (603 ko)

Manual abstract: user guide SUB-ZERO WARMINGDRAWER

Detailed instructions for use are in the User's Guide.

[. . . ] W A R M I N G D R AW E R INSTALLATION INSTRUCTIONS C O N TA C T I N F O R M AT I O N Wolf Customer Service: 800-332-9513 Website: wolfappliance. com As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed. Another footnote we would like to identify is IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation. WOLF ® is a registered trademark of Wolf Appliance Company, LLC W O L F WA R M I N G D R AW E R I N S TA L L AT I O N R E Q U I R E M E N T S IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf authorized service center technician. Installer: Please read the entire Installation Instructions prior to installation. [. . . ] When installed above a built-in oven, a minimum of 7/8" (22) is required. IMPORTANT NOTE: In an overlay application, the amount of space between warming drawer and built-in oven openings may need to be increased depending on the size of the overlay panel and the amount of overlap. 24" min (610) CABINET DEPTH 25" min (635) CABINET DEPTH 33" (838) CABINET WIDTH 24" min (610) 27 3/16" (691) 24" min (610) 27 3/16" (691) 28 1/2" (724) 30-INCH OVEN OPENING WIDTH 2" (51) x 2" (51) ANTI-TIP BLOCK 10 1/4" 9 7/8" (251) (260) OPENING HEIGHT 2" (51) x 2" (51) ANTI-TIP BLOCK 10 1/4" 9 7/8" (251) 1 1/2" min* (38) (260) OPENING HEIGHT 5" 4" (102) (127) E 1 1/2" min* (38) 24" (610) + THICKNESS OF DRAWER FACE FOR OPENING DEPTH 24" min (610) OPENING DEPTH 29 1/2" (749) WARMING DRAWER OPENING WIDTH OVERLAY APPLICATION INSET APPLICATION NOTE: Refer to the built-in 30" (762) single oven specifications for electrical location. *Dimension may increase depending on the size of the drawer front panel. Installation with Built-In Oven ­ Integrated Drawer Front 10 I N S TA L L AT I O N I N S T R U C T I O N S I N T E G R AT E D D R A W E R F R O N T I N S TA L L A T I O N O P T I O N S The Wolf warming drawer with integrated drawer front may be installed in combination with a 30" (762) single built-in oven and microwave with 30" (762) trim, provided the warming drawer is fully enclosed, top and bottom. The Wolf warming drawer with integrated drawer front may also be installed in combination with a 36" (914) single built-in oven and microwave with 36" (914) trim. It must be a minimum of 1" (25) above the toe kick to allow for the overlap of the warming drawer trim. Refer to installation instructions provided with the built-in oven and microwave for additional specifications. The Wolf warming drawer with integrated drawer front may be installed next to or above another Wolf warming drawer, provided each unit is fully enclosed, top and bottom. 24" min (610) CABINET DEPTH 25" min (635) CABINET DEPTH 33" (838) CABINET WIDTH 1" min (25) 1" min (25) MICROWAVE ROUGH OPENING E 24" min (610) 27 3/16" (691) 24" min (610) 27 3/16" (691) 28 1/2" (724) 30-INCH OVEN OPENING WIDTH 2" (51) x 2" (51) ANTI-TIP BLOCK 10 1/4" 9 7/8" (251) (260) OPENING HEIGHT 2" (51) x 2" (51) ANTI-TIP BLOCK 10 1/4" 9 7/8" (251) 1 1/2" min* (38) (260) OPENING HEIGHT 5" 4" (102) (127) E 24" min (610) OPENING DEPTH 24" (610) + THICKNESS OF DRAWER FACE FOR OPENING DEPTH 1 1/2" min* (38) 29 1/2" (749) WARMING DRAWER OPENING WIDTH OVERLAY APPLICATION INSET APPLICATION NOTE: Refer to the built-in 30" (762) single oven specifications for electrical location. *Dimension may increase depending on the size of the drawer front panel. Installation with 30" (762) Built-In Oven and Microwave ­ Integrated Drawer Front Dimensions in parentheses are in millimeters unless otherwise specified. 11 W O L F WA R M I N G D R AW E R ELECTRICAL R E Q U I R E M E N T S I M P O R TA N T N OT E You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. The Wolf warming drawer requires a separate, grounded 120 V AC, 50/60 Hz power supply and must be connected to an individual properly grounded branch circuit and protected by a 15 or 20 amp circuit breaker or time delay fuse. IMPORTANT NOTE: The warming drawer is equipped with a power supply cord with a 3-prong grounding plug, which must be plugged into a mating 3-prong grounding-type electrical outlet to minimize the possibility of electric shock. The location of the outlet is not critical, but must be within reach of the 6' (1. 8 m) power cord. If it is placed behind the unit, make sure the outlet is flush with the back wall. For location of the electrical outlet, refer to the installation illustration for your specific installation on pages 5­11. The electrical outlet can be located in an adjacent cabinet within reach of the power cord. If the outlet is located in an adjacent cabinet, you will need to drill a 2" (51) diameter hole in the cabinet wall for the power cord. If two warming drawers are installed side by side, they can operate from the same electrical outlet. A 30 amp circuit breaker is required for this installation. IMPORTANT NOTE: When installed outdoors, A ground fault circuit interrupter (GFCI) is required to reduce the risk of electrical shock. In addition, be aware of local codes and ordinances when installing your service. The electrical outlet must be checked by a qualified electrician to be sure that it is wired with the correct polarity. Verify that the outlet provides 120 V AC and is properly grounded. Do not use an extension cord or twoprong adapter. Do not remove the power supply cord ground prong. 12 I N S TA L L AT I O N I N S T R U C T I O N S CABINET S U P P O RT S U N PAC K T H E W A R M I N G D R A W E R IMPORTANT NOTE: When the warming drawer is installed with a built-in oven, additional clearance between openings may be required. Check that oven supports do not obstruct the interior dimensions required for the warming drawer. The warming drawer with stainless steel drawer front may be supported by either a solid platform, 2" (51) x 2" (51) runners or 2" (51) x 4" (102) runners. The platform or runners must be level, rigidly mounted and flush with the bottom edge of the opening. If an integrated drawer front is used, it must be supported by a 5/8" (16) solid platform. The platform will need to be recessed and allow for overlap of the warming drawer collar. [. . . ] Drill pilot holes in each side hole, one located toward the front on each side of the warming drawer. Turn power back on to the electrical outlet. Location of side hole Warming drawer installation Dimensions in parentheses are in millimeters unless otherwise specified. 17 W O L F WA R M I N G D R AW E R I N T E G R AT E D F R O N T P A N E L I N S TA L L F R O N T P A N E L T O D R A W E R Remove the front panel that came attached to the warming drawer. Using the six screws, install the metal panel from the integrated drawer front kit onto the warming drawer front. Make sure the brushed side of the metal panel is facing the warming drawer interior. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO WARMINGDRAWER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO WARMINGDRAWER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.